1. Use of covered stents in simultaneous management of coarctation of the aorta and patent ductus arteriosus. Hekim Yılmaz E; Bulut MO; Küçük M; Yücel İK; Erdem A; Çelebi A Anatol J Cardiol; 2018 Apr; 19(4):332-336. PubMed ID: 29578201 [TBL] [Abstract][Full Text] [Related]
2. Simultaneous stent implantation for coarctation of the aorta and closure of patent ductus arteriosus using the Amplatzer duct occluder. Hakim F; Hawelleh AA; Goussous Y; Hijazi ZM Catheter Cardiovasc Interv; 1999 May; 47(1):36-8. PubMed ID: 10385155 [TBL] [Abstract][Full Text] [Related]
3. Stent implantation for coarctation of aorta caused by a Rashkind patent ductus arteriosus umbrella. Beck A; Birk E; Blieden LC; Bruckheimer E Catheter Cardiovasc Interv; 2004 Sep; 63(1):80-2. PubMed ID: 15343573 [TBL] [Abstract][Full Text] [Related]
4. [Rotational angiography in monitoring of covered CP stent implantation in patient with critical aortic coarctation and patent ductus arteriosus]. Góreczny S; Dryżek P; Moszura T; Politowska B; Niedzielska-Stanek B; Moll JA; Sysa A Kardiol Pol; 2012; 70(5):505-7. PubMed ID: 22623247 [TBL] [Abstract][Full Text] [Related]
5. Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stent. Sadiq M; Malick NH; Qureshi SA Catheter Cardiovasc Interv; 2003 Jul; 59(3):387-90. PubMed ID: 12822166 [TBL] [Abstract][Full Text] [Related]
6. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus. Singhi AK; Sivakumar K Indian Heart J; 2012; 64(4):423-6. PubMed ID: 22929832 [TBL] [Abstract][Full Text] [Related]
7. Cheatham-Platinum stent for native and recurrent aortic coarctation in children and adults: immediate and early follow-up results. Erdem A; Akdeniz C; Sarıtaş T; Erol N; Demir F; Karaci AR; Yalçın Y; Celebi A Anadolu Kardiyol Derg; 2011 Aug; 11(5):441-9. PubMed ID: 21712167 [TBL] [Abstract][Full Text] [Related]
8. Successful transcatheter balloon dilatation of coarctation of aorta and coil occlusion of patent ductus arteriosus in a single catheterization procedure. Celebi A; Yalçin Y; Erdem A; Zeybek C; Akdeniz C; Polat TB Turk J Pediatr; 2007; 49(1):94-7. PubMed ID: 17479653 [TBL] [Abstract][Full Text] [Related]
9. Aortic coarctation complicated by wall aneurysm: the role of covered stents. Butera G; Heles M; MacDonald ST; Carminati M Catheter Cardiovasc Interv; 2011 Nov; 78(6):926-32. PubMed ID: 20824756 [TBL] [Abstract][Full Text] [Related]
10. Percutaneous closure of patent ductus arteriosus in children using amplatzer duct occluder II: relationship between PDA type and risk of device protrusion into the descending aorta. Masri S; El Rassi I; Arabi M; Tabbakh A; Bitar F Catheter Cardiovasc Interv; 2015 Aug; 86(2):E66-72. PubMed ID: 26032159 [TBL] [Abstract][Full Text] [Related]
11. Interventional cardiac catheterization therapy for combined coarctation of the aorta and patent ductus arteriosus: successful outcome in two infants. Geggel RL; Hijazi ZM; Rhodes J Cathet Cardiovasc Diagn; 1996 May; 38(1):67-70; discussion 71. PubMed ID: 8722861 [TBL] [Abstract][Full Text] [Related]
12. [Our initial experience with stent implantation for aortic coarctation in adults]. Yazıcı HU; Göktekin O; Ulus T; Temel K; Nadir A; Nasifov M; Birdane A; Unalır A; Ata N Turk Kardiyol Dern Ars; 2011 Apr; 39(3):214-8. PubMed ID: 21532297 [TBL] [Abstract][Full Text] [Related]
13. Development of aortic coarctation following device closure of patent ductus arteriosus. Doshi AR; Rao PS J Invasive Cardiol; 2013 Sep; 25(9):464-7. PubMed ID: 23995721 [TBL] [Abstract][Full Text] [Related]
14. Single therapeutic catheterization to treat coexisting coarctation of the aorta and patent ductus arteriosus. Ing FF; McMahon WS; Johnson GL; Vick GW; Mullins CE Am J Cardiol; 1997 Feb; 79(4):535-7. PubMed ID: 9052372 [TBL] [Abstract][Full Text] [Related]
15. Innovative resource utilization to fashion individualized covered stents in the setting of aortic coarctation. Kenny D; Cao QL; Kavinsky C; Hijazi ZM Catheter Cardiovasc Interv; 2011 Sep; 78(3):413-8. PubMed ID: 21976432 [TBL] [Abstract][Full Text] [Related]
16. Native coarctation of aorta and large hypertensive patent ductus arteriosus: Management using a covered stent. Awasthy N; Tomar M; Radhakrishnan S Indian Heart J; 2015 Dec; 67 Suppl 3(Suppl 3):S117-9. PubMed ID: 26995418 [No Abstract] [Full Text] [Related]
17. Self-expanding and balloon expandable covered stents in the treatment of aortic coarctation with or without aneurysm formation. Kenny D; Margey R; Turner MS; Tometzki AJ; Walsh KP; Martin RP Catheter Cardiovasc Interv; 2008 Jul; 72(1):65-71. PubMed ID: 18412235 [TBL] [Abstract][Full Text] [Related]
18. Covered stents in the management of native coarctation of the aorta--intermediate and long-term follow-up. Sadiq M; Ur Rehman A; Qureshi AU; Qureshi SA Catheter Cardiovasc Interv; 2013 Oct; 82(4):511-8. PubMed ID: 23592275 [TBL] [Abstract][Full Text] [Related]
19. From bare to covered: 15-year single center experience and follow-up in trans-catheter stent implantation for aortic coarctation. Butera G; Manica JL; Marini D; Piazza L; Chessa M; Filho RI; Sarmento Leite RE; Carminati M Catheter Cardiovasc Interv; 2014 May; 83(6):953-63. PubMed ID: 24459104 [TBL] [Abstract][Full Text] [Related]
20. Ductus-dependent aortic coarctation with a left-to-right shunt through the ductus: report of one case. Cheng CF; Wu MH; Wang JK Int J Cardiol; 1995 May; 49(3):209-12; discussion 212-3. PubMed ID: 7649666 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]