These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 29578897)

  • 1. Development and Validation of the Realistic Anthropomorphic Flexible (RAF) Phantom.
    Lombardo PA; Vanhavere F; Lebacq AL; Struelens L; Bogaerts R
    Health Phys; 2018 May; 114(5):486-499. PubMed ID: 29578897
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conversion of ICRP male reference phantom to polygon-surface phantom.
    Yeom YS; Han MC; Kim CH; Jeong JH
    Phys Med Biol; 2013 Oct; 58(19):6985-7007. PubMed ID: 24029733
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On the need to revise the arm structure in stylized anthropomorphic phantoms in lateral photon irradiation geometry.
    Lee C; Lee C; Lee JK
    Phys Med Biol; 2006 Nov; 51(21):N393-402. PubMed ID: 17047258
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computation Speeds and Memory Requirements of Mesh-Type ICRP Reference Computational Phantoms in Geant4, MCNP6, and PHITS.
    Yeom YS; Han MC; Choi C; Han H; Shin B; Furuta T; Kim CH
    Health Phys; 2019 May; 116(5):664-676. PubMed ID: 30844899
    [TBL] [Abstract][Full Text] [Related]  

  • 5. All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry.
    Kramer R; Khoury HJ; Vieira JW; Loureiro EC; Lima VJ; Lima FR; Hoff G
    Phys Med Biol; 2004 Dec; 49(23):5203-16. PubMed ID: 15656272
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms.
    Na YH; Zhang B; Zhang J; Caracappa PF; Xu XG
    Phys Med Biol; 2010 Jul; 55(13):3789-811. PubMed ID: 20551505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mouse S-factors based on Monte Carlo simulations in the anatomical realistic Moby phantom for internal dosimetry.
    Larsson E; Strand SE; Ljungberg M; Jönsson BA
    Cancer Biother Radiopharm; 2007 Jun; 22(3):438-42. PubMed ID: 17651052
    [TBL] [Abstract][Full Text] [Related]  

  • 8. RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beams.
    Zhang J; Na YH; Caracappa PF; Xu XG
    Phys Med Biol; 2009 Oct; 54(19):5885-908. PubMed ID: 19759412
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact on 141Ce, 144Ce, 95Zr, and 90Sr beta emitter dose coefficients of photon and electron SAFs calculated with ICRP/ICRU reference adult voxel computational phantoms.
    Li WB; Zankl M; Schlattl H; Petoussi-Henss N; Eckerman KF; Bolch WE; Oeh U; Hoeschen C
    Health Phys; 2010 Oct; 99(4):503-10. PubMed ID: 20838091
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
    DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
    Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models.
    Lee C; Lodwick D; Hasenauer D; Williams JL; Lee C; Bolch WE
    Phys Med Biol; 2007 Jun; 52(12):3309-33. PubMed ID: 17664546
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of the ICRP/ICRU reference computational phantoms to internal dosimetry: calculation of specific absorbed fractions of energy for photons and electrons.
    Hadid L; Desbrée A; Schlattl H; Franck D; Blanchardon E; Zankl M
    Phys Med Biol; 2010 Jul; 55(13):3631-41. PubMed ID: 20526035
    [TBL] [Abstract][Full Text] [Related]  

  • 13. FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations.
    Kramer R; Cassola VF; Khoury HJ; Vieira JW; Lima VJ; Brown KR
    Phys Med Biol; 2010 Jan; 55(1):163-89. PubMed ID: 20009181
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry.
    Lee C; Lodwick D; Williams JL; Bolch WE
    Med Phys; 2008 Jun; 35(6):2366-82. PubMed ID: 18649470
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of skeletal system for mesh-type ICRP reference adult phantoms.
    Yeom YS; Wang ZJ; Nguyen TT; Kim HS; Choi C; Han MC; Kim CH; Lee JK; Chung BS; Zankl M; Petoussi-Henss N; Bolch WE; Lee C
    Phys Med Biol; 2016 Oct; 61(19):7054-7073. PubMed ID: 27648514
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison between effective doses for voxel-based and stylized exposure models from photon and electron irradiation.
    Kramer R; Khoury HJ; Vieira JW
    Phys Med Biol; 2005 Nov; 50(21):5105-26. PubMed ID: 16237244
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Selected organ dose conversion coefficients for external photons calculated using ICRP adult voxel phantoms and Monte Carlo code FLUKA.
    Patni HK; Nadar MY; Akar DK; Bhati S; Sarkar PK
    Radiat Prot Dosimetry; 2011 Nov; 147(3):406-16. PubMed ID: 21147784
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of absorbed and effective doses to patients from radiopharmaceuticals using the ICRP 110 reference computational phantoms and ICRP 103 formulation.
    Hadid L; Gardumi A; Desbrée A
    Radiat Prot Dosimetry; 2013 Sep; 156(2):141-59. PubMed ID: 23525914
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient internal anatomy.
    Wayson MB; Bolch WE
    Phys Med Biol; 2018 Apr; 63(8):085006. PubMed ID: 29546844
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air.
    Hiller M; Dewji SA
    Radiat Prot Dosimetry; 2017 Jul; 175(3):336-343. PubMed ID: 28204766
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.