These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 29582996)

  • 1. Conventional-Flow Liquid Chromatography-Mass Spectrometry for Exploratory Bottom-Up Proteomic Analyses.
    Lenčo J; Vajrychová M; Pimková K; Prokšová M; Benková M; Klimentová J; Tambor V; Soukup O
    Anal Chem; 2018 Apr; 90(8):5381-5389. PubMed ID: 29582996
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-microm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis.
    Luo Q; Yue G; Valaskovic GA; Gu Y; Wu SL; Karger BL
    Anal Chem; 2007 Aug; 79(16):6174-81. PubMed ID: 17625912
    [TBL] [Abstract][Full Text] [Related]  

  • 3. More sensitive and quantitative proteomic measurements using very low flow rate porous silica monolithic LC columns with electrospray ionization-mass spectrometry.
    Luo Q; Tang K; Yang F; Elias A; Shen Y; Moore RJ; Zhao R; Hixson KK; Rossie SS; Smith RD
    J Proteome Res; 2006 May; 5(5):1091-7. PubMed ID: 16674098
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses.
    Lenčo J; Šemlej T; Khalikova MA; Fabrik I; Švec F
    J Proteome Res; 2021 Jan; 20(1):420-432. PubMed ID: 33085896
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hydrophilic interaction chromatography using a meter-scale monolithic silica capillary column for proteomics LC-MS.
    Horie K; Kamakura T; Ikegami T; Wakabayashi M; Kato T; Tanaka N; Ishihama Y
    Anal Chem; 2014 Apr; 86(8):3817-24. PubMed ID: 24666247
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhancing Sensitivity of Microflow-Based Bottom-Up Proteomics through Postcolumn Solvent Addition.
    Distler U; Łącki MK; Schumann S; Wanninger M; Tenzer S
    Anal Chem; 2019 Jun; 91(12):7510-7515. PubMed ID: 31117400
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multiple solvent elution, a method to counter the effects of coelution and ion suppression in LC-MS analysis in bottom up proteomics.
    Budamgunta H; Maes E; Willems H; Menschaert G; Schildermans K; Kumar AA; Boonen K; Baggerman G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Aug; 1124():256-264. PubMed ID: 31238262
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Extended Range Proteomic Analysis (ERPA): a new and sensitive LC-MS platform for high sequence coverage of complex proteins with extensive post-translational modifications-comprehensive analysis of beta-casein and epidermal growth factor receptor (EGFR).
    Wu SL; Kim J; Hancock WS; Karger B
    J Proteome Res; 2005; 4(4):1155-70. PubMed ID: 16083266
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stage-frit: A straightforward sub-2 μm nano-liquid chromatography column fabrication for proteomic analysis.
    Hsieh MY; Hsiao HH
    Anal Chim Acta; 2015 Jul; 886():200-6. PubMed ID: 26320654
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 3D HPLC-MS with Reversed-Phase Separation Functionality in All Three Dimensions for Large-Scale Bottom-Up Proteomics and Peptide Retention Data Collection.
    Spicer V; Ezzati P; Neustaeter H; Beavis RC; Wilkins JA; Krokhin OV
    Anal Chem; 2016 Mar; 88(5):2847-55. PubMed ID: 26849966
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development and performance evaluation of an ultralow flow nanoliquid chromatography-tandem mass spectrometry set-up.
    Köcher T; Pichler P; De Pra M; Rieux L; Swart R; Mechtler K
    Proteomics; 2014 Sep; 14(17-18):1999-2007. PubMed ID: 24920484
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Advancement in stationary phase for peptide separation helps in protein identification: application to atheroma plaque proteomics using nano-chip liquid chromatography and mass spectrometry.
    Delporte C; Noyon C; Raynal P; Dufour D; Nève J; Abts F; Haex M; Zouaoui Boudjeltia K; Van Antwerpen P
    J Chromatogr A; 2015 Mar; 1385():116-23. PubMed ID: 25680550
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preparation of 20-microm-i.d. silica-based monolithic columns and their performance for proteomics analyses.
    Luo Q; Shen Y; Hixson KK; Zhao R; Yang F; Moore RJ; Mottaz HM; Smith RD
    Anal Chem; 2005 Aug; 77(15):5028-35. PubMed ID: 16053318
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Picoflow Liquid Chromatography-Mass Spectrometry for Ultrasensitive Bottom-Up Proteomics Using 2-μm-i.d. Open Tubular Columns.
    Xiang P; Zhu Y; Yang Y; Zhao Z; Williams SM; Moore RJ; Kelly RT; Smith RD; Liu S
    Anal Chem; 2020 Apr; 92(7):4711-4715. PubMed ID: 32208662
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved Sensitivity of Ultralow Flow LC-MS-Based Proteomic Profiling of Limited Samples Using Monolithic Capillary Columns and FAIMS Technology.
    Greguš M; Kostas JC; Ray S; Abbatiello SE; Ivanov AR
    Anal Chem; 2020 Nov; 92(21):14702-14712. PubMed ID: 33054160
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extraction of intrinsic column peak profiles of narrow-bore and microbore columns by peak deconvolution methods.
    Gritti F; Wahab F
    Anal Chim Acta; 2021 Oct; 1180():338851. PubMed ID: 34538318
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of NanoLC Column and Gradient Length as well as MS/MS Frequency and Sample Complexity on Shotgun Protein Identification of Marine Bacteria.
    Wöhlbrand L; Rabus R; Blasius B; Feenders C
    J Mol Microbiol Biotechnol; 2017; 27(3):199-212. PubMed ID: 28850952
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect and potential of using a temperature controlled separation column with ultra-high pressure microcapillary liquid chromatography/tandem mass spectrometry on proteomic analysis.
    Hyung SW; Kim MS; Mun DG; Lee H; Lee SW
    Analyst; 2011 May; 136(10):2100-5. PubMed ID: 21431206
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reversed-Phase Liquid Chromatography of Peptides for Bottom-Up Proteomics: A Tutorial.
    Lenčo J; Jadeja S; Naplekov DK; Krokhin OV; Khalikova MA; Chocholouš P; Urban J; Broeckhoven K; Nováková L; Švec F
    J Proteome Res; 2022 Dec; 21(12):2846-2892. PubMed ID: 36355445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Separation techniques hyphenated to electrospray-tandem mass spectrometry in proteomics: capillary electrophoresis versus nanoliquid chromatography.
    Pelzing M; Neusüss C
    Electrophoresis; 2005 Jul; 26(14):2717-28. PubMed ID: 15966011
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.