These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 29584647)

  • 21. Adhesion of new bioactive glass coating.
    Schrooten J; Van Oosterwyck H; Vander Sloten J; Helsen JA
    J Biomed Mater Res; 1999 Mar; 44(3):243-52. PubMed ID: 10397926
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Interface Strength, Damage and Fracture between Ceramic Films and Metallic Substrates.
    Liang L; Chen L; Wu L; Tan H
    Materials (Basel); 2021 Jan; 14(2):. PubMed ID: 33445778
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of Interlaminar Failure on the Scratch Damage of Automotive Coatings: Cohesive Zone Modeling.
    Huang M; Yang H; Zou C; Zang M; Chen S
    Polymers (Basel); 2023 Jan; 15(3):. PubMed ID: 36772038
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A new concept and finite-element study on dental bond strength tests.
    Jin XZ; Homaei E; Matinlinna JP; Tsoi JKH
    Dent Mater; 2016 Oct; 32(10):e238-e250. PubMed ID: 27497744
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Thermal residual stresses near the interface between plasma-sprayed hydroxyapatite coating and titanium substrate: finite element analysis and synchrotron radiation measurements.
    Cofino B; Fogarassy P; Millet P; Lodini A
    J Biomed Mater Res A; 2004 Jul; 70(1):20-7. PubMed ID: 15174105
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Thermal stresses in metal-ceramic specimens for the ISO crack initiation test (three-point flexure bond test).
    Lenz J; Kessel S
    Dent Mater; 1998 Jul; 14(4):277-80. PubMed ID: 10379256
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A quantitative in vitro method to predict the adhesion lifetime of diamond-like carbon thin films on biomedical implants.
    Falub CV; Thorwarth G; Affolter C; Müller U; Voisard C; Hauert R
    Acta Biomater; 2009 Oct; 5(8):3086-97. PubMed ID: 19450711
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Interfacial coherency stress distribution in TiN/AlN bilayer and multilayer films studied by FEM analysis.
    Chawla V; Holec D; Mayrhofer PH
    Comput Mater Sci; 2012 Apr; 55(3):211-216. PubMed ID: 27570370
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Stress-induced surface instabilities and defects in thin films sputter deposited on compliant substrates.
    Ibru T; Kalaitzidou K; Baldwin JK; Antoniou A
    Soft Matter; 2017 Jun; 13(22):4035-4046. PubMed ID: 28517009
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Tailoring Interfacial Properties by Controlling Carbon Nanotube Coating Thickness on Glass Fibers Using Electrophoretic Deposition.
    Tamrakar S; An Q; Thostenson ET; Rider AN; Haque BZ; Gillespie JW
    ACS Appl Mater Interfaces; 2016 Jan; 8(2):1501-10. PubMed ID: 26699906
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [A mechanical study on new ceramic crowns and bridges for clinical use].
    Hino T
    Osaka Daigaku Shigaku Zasshi; 1990 Jun; 35(1):240-67. PubMed ID: 2135407
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Efficient Heat Shielding of Steel with Multilayer Nanocomposite Thin Film.
    Long CT; Wang R; Shoalmire C; Antao DS; Shamberger PJ; Grunlan JC
    ACS Appl Mater Interfaces; 2021 Apr; 13(16):19369-19376. PubMed ID: 33861561
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vitro mechanical integrity of hydroxyapatite coatings on Ti-6Al-4V implants under shear loading.
    Zhang C; Leng Y; Chen J
    J Biomed Mater Res; 2001 Sep; 56(3):342-50. PubMed ID: 11372051
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of Jig Design and Assessment of Stress Distribution in Testing Metal-Ceramic Adhesion.
    Özcan M; Kojima AN; Nishioka RS; Mesquita AM; Bottino MA; Filho GD
    J Prosthodont; 2016 Dec; 25(8):665-669. PubMed ID: 26436821
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Finite strain stress fields near the tip of an interface crack between a soft incompressible elastic material and a rigid substrate.
    Krishnan VR; Hui CY
    Eur Phys J E Soft Matter; 2009 May; 29(1):61-72. PubMed ID: 19437055
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Interfacial bond strength of electrophoretically deposited hydroxyapatite coatings on metals.
    Wei M; Ruys AJ; Swain MV; Kim SH; Milthorpe BK; Sorrell CC
    J Mater Sci Mater Med; 1999 Jul; 10(7):401-9. PubMed ID: 15348125
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Note: A single specimen channel crack growth technique applied to brittle thin films on polymer substrates.
    Kim K; Graham S; Pierron ON
    Rev Sci Instrum; 2017 Mar; 88(3):036102. PubMed ID: 28372385
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Phase-Field Model for the Simulation of Brittle-Anisotropic and Ductile Crack Propagation in Composite Materials.
    Herrmann C; Schneider D; Schoof E; Schwab F; Nestler B
    Materials (Basel); 2021 Aug; 14(17):. PubMed ID: 34501046
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Healing of polymer interfaces: Interfacial dynamics, entanglements, and strength.
    Ge T; Robbins MO; Perahia D; Grest GS
    Phys Rev E Stat Nonlin Soft Matter Phys; 2014 Jul; 90(1):012602. PubMed ID: 25122327
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Tensile behaviors of Ti
    Luo S; Patole S; Anwer S; Li B; Delclos T; Gogotsi O; Zahorodna V; Balitskyi V; Liao K
    Nanotechnology; 2020 Sep; 31(39):395704. PubMed ID: 32434169
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.