BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

603 related articles for article (PubMed ID: 29590668)

  • 1. Safety of lumen-apposing stent with or without coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a retrospective study.
    Puga M; Consiglieri CF; Busquets J; Pallarès N; Secanella L; Peláez N; Fabregat J; Castellote J; Gornals JB
    Endoscopy; 2018 Oct; 50(10):1022-1026. PubMed ID: 29590668
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Increased Incidence of Pseudoaneurysm Bleeding With Lumen-Apposing Metal Stents Compared to Double-Pigtail Plastic Stents in Patients With Peripancreatic Fluid Collections.
    Brimhall B; Han S; Tatman PD; Clark TJ; Wani S; Brauer B; Edmundowicz S; Wagh MS; Attwell A; Hammad H; Shah RJ
    Clin Gastroenterol Hepatol; 2018 Sep; 16(9):1521-1528. PubMed ID: 29474970
    [TBL] [Abstract][Full Text] [Related]  

  • 3. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos).
    Siddiqui AA; Adler DG; Nieto J; Shah JN; Binmoeller KF; Kane S; Yan L; Laique SN; Kowalski T; Loren DE; Taylor LJ; Munigala S; Bhat YM
    Gastrointest Endosc; 2016 Apr; 83(4):699-707. PubMed ID: 26515956
    [TBL] [Abstract][Full Text] [Related]  

  • 4. EUS-guided drainage of pancreatic fluid collections using lumen apposing metal stents: An international, multicenter experience.
    Kumta NA; Tyberg A; Bhagat VH; Siddiqui AA; Kowalski TE; Loren DE; Desai AP; Sarkisian AM; Brown EG; Karia K; Gaidhane M; Kedia P; Tarnasky PR; Patel U; Adler D; Taylor LJ; Petrone M; Arcidiacono P; Yachimski PS; Weine D; Sundararajan S; Deprez PH; Mouradides C; Ho S; Javed S; Easler JJ; Raijman I; Vazquez-Sequeiros E; Sawhney M; Berzin TM; Kahaleh M
    Dig Liver Dis; 2019 Nov; 51(11):1557-1561. PubMed ID: 31272934
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Head-to-head comparison between endoscopic ultrasound guided lumen apposing metal stent and plastic stents for the treatment of pancreatic fluid collections: A systematic review and meta-analysis.
    Guzmán-Calderón E; Chacaltana A; Díaz R; Li B; Martinez-Moreno B; Aparicio JR
    J Hepatobiliary Pancreat Sci; 2022 Feb; 29(2):198-211. PubMed ID: 34107170
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of three different stents for endoscopic ultrasound-guided drainage of pancreatic fluid collection: A large retrospective study.
    Wang Z; Zhao S; Meng Q; Wang S; Chen Y; Wang F; Li Q; Yao J; Du Y; Jin Z; Bai Y; Li Z; Wang D
    J Gastroenterol Hepatol; 2019 Apr; 34(4):791-798. PubMed ID: 30475420
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Protocol of early lumen apposing metal stent removal for pseudocysts and walled off necrosis avoids bleeding complications.
    Ahmad W; Fehmi SA; Savides TJ; Anand G; Chang MA; Kwong WT
    Scand J Gastroenterol; 2020 Feb; 55(2):242-247. PubMed ID: 31942808
    [No Abstract]   [Full Text] [Related]  

  • 8. Is a coaxial plastic stent within a lumen-apposing metal stent useful for the management of distal malignant biliary obstruction?
    Garcia-Sumalla A; Loras C; Guarner-Argente C; Velasquez-Rodriguez JG; Andujar X; Salord S; Busquets J; Tebe C; Laquente B; Gornals JB
    Surg Endosc; 2021 Aug; 35(8):4873-4881. PubMed ID: 33721090
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages: A systematic review focusing on issues and rescue management.
    Armellini E; Metelli F; Anderloni A; Cominardi A; Aragona G; Marini M; Pace F
    World J Gastroenterol; 2023 Jun; 29(21):3341-3361. PubMed ID: 37377584
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lumen-apposing metal stents versus traditional self-expanding metal stents for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis.
    Tian Y; Yin C; Ma Y; Fu G; Liu R; Ran H; Pan T; Xiao Y; Wen X
    Surg Endosc; 2024 Feb; 38(2):586-596. PubMed ID: 38151677
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficacy and Safety of Lumen-Apposing Metal Stents in Management of Pancreatic Fluid Collections: Are They Better Than Plastic Stents? A Systematic Review and Meta-Analysis.
    Hammad T; Khan MA; Alastal Y; Lee W; Nawras A; Ismail MK; Kahaleh M
    Dig Dis Sci; 2018 Feb; 63(2):289-301. PubMed ID: 29282638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success.
    Siddiqui AA; Kowalski TE; Loren DE; Khalid A; Soomro A; Mazhar SM; Isby L; Kahaleh M; Karia K; Yoo J; Ofosu A; Ng B; Sharaiha RZ
    Gastrointest Endosc; 2017 Apr; 85(4):758-765. PubMed ID: 27566053
    [TBL] [Abstract][Full Text] [Related]  

  • 13. EUS-guided transluminal drainage using lumen-apposing metal stents with or without coaxial plastic stents for treatment of walled-off necrotizing pancreatitis: a prospective bicentric randomized controlled trial.
    Vanek P; Falt P; Vitek P; Zoundjiekpon V; Horinkova M; Zapletalova J; Lovecek M; Urban O
    Gastrointest Endosc; 2023 Jun; 97(6):1070-1080. PubMed ID: 36646148
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel lumen-apposing metal stent with an anti-reflux valve for endoscopic ultrasound-guided drainage of pseudocysts and walled-off necrosis: A pilot study.
    Cho IR; Chung MJ; Jo JH; Lee HS; Park JY; Bang S; Park SW; Song SY
    PLoS One; 2019; 14(9):e0221812. PubMed ID: 31483821
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The safety and efficacy of a new 20-mm lumen apposing metal stent (lams) for the endoscopic treatment of pancreatic and peripancreatic fluid collections: a large international, multicenter study.
    Anderloni A; Fabbri C; Nieto J; Uwe W; Dollhopf M; Aparicio JR; Perez-Miranda M; Tarantino I; Arlt A; Vleggaar F; Vanbiervliet G; Hampe J; Kahaleh M; Vila JJ; Dayyeh BKA; Storm AC; Fugazza A; Binda C; Charachon A; Sevilla-Ribota S; Tyberg A; Robert M; Wani S; Repici A; Sethi A; Khashab MA; Kunda R
    Surg Endosc; 2021 Apr; 35(4):1741-1748. PubMed ID: 32323015
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lumen-apposing metal stents with or without coaxial plastic stent placement for the management of pancreatic fluid collections.
    AbiMansour JP; Jaruvongvanich V; Velaga S; Law RJ; Storm AC; Topazian MD; Levy MJ; Alexander R; Vargas EJ; Bofill-Garcia A; Matin JA; Petersen BT; Abu Dayyeh BK; Chandrasekhara V
    Gastrointest Endosc; 2024 Jan; 99(1):104-107. PubMed ID: 37722511
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Double pigtail stent placement as an adjunct to lumen-apposing metal stentsfor drainage of pancreatic fluid collections may not affect outcomes: A multicenter experience.
    Shamah SP; Sahakian AB; Chapman CG; Buxbaum JL; Muniraj T; Aslanian HA; Villa E; Cho J; Haider HI; Waxman I; Siddiqui UD
    Endosc Ultrasound; 2022; 11(1):53-58. PubMed ID: 35102901
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Lumen-apposing metal stents in management of pancreatic fluid collections: The nobody's land of removal timing.
    De Angelis CG; Venezia L; Cortegoso Valdivia P; Rizza S; Bruno M; Pellicano R
    Saudi J Gastroenterol; 2019; 25(6):335-340. PubMed ID: 31823862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluoroscopy-assisted vs fluoroless endoscopic ultrasound-guided transmural drainage of pancreatic fluid collections: A comparative study.
    Consiglieri CF; Gornals JB; Busquets J; Peláez N; Secanella L; De-La-Hera M; Sanzol R; Fabregat J; Castellote J
    Gastroenterol Hepatol; 2018 Jan; 41(1):12-21. PubMed ID: 28882615
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel self-expanding biflanged metal stent vs tubular metal stent for EUS-guided transmural drainage of pancreatic pseudocyst: A retrospective, cohort study.
    Yao Y; Zhang D; Guo J; Qi K; Li F; Zhu J; Wang D; Chen J; Xu C; Wang L; Wang K; Jin Z; Li Z
    Medicine (Baltimore); 2019 Jan; 98(3):e14179. PubMed ID: 30653165
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.