575 related articles for article (PubMed ID: 29594544)
1. Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles.
Shoaie N; Forouzandeh M; Omidfar K
Mikrochim Acta; 2018 Mar; 185(4):217. PubMed ID: 29594544
[TBL] [Abstract][Full Text] [Related]
2. Glucose oxidase immobilized amine terminated multiwall carbon nanotubes/reduced graphene oxide/polyaniline/gold nanoparticles modified screen-printed carbon electrode for highly sensitive amperometric glucose detection.
Maity D; C R M; R T RK
Mater Sci Eng C Mater Biol Appl; 2019 Dec; 105():110075. PubMed ID: 31546385
[TBL] [Abstract][Full Text] [Related]
3. Electrochemical immunoassay for detection of prostate specific antigen based on peptide nanotube-gold nanoparticle-polyaniline immobilized pencil graphite electrode.
Vural T; Yaman YT; Ozturk S; Abaci S; Denkbas EB
J Colloid Interface Sci; 2018 Jan; 510():318-326. PubMed ID: 28957748
[TBL] [Abstract][Full Text] [Related]
4. Gold nanoparticles conjugates-amplified aptamer immunosensing screen-printed carbon electrode strips for thrombin detection.
Yeh FY; Liu TY; Tseng IH; Yang CW; Lu LC; Lin CS
Biosens Bioelectron; 2014 Nov; 61():336-43. PubMed ID: 24912033
[TBL] [Abstract][Full Text] [Related]
5. Electrochemical sandwich immunoassay for Escherichia coli O157:H7 based on the use of magnetic nanoparticles and graphene functionalized with electrocatalytically active Au@Pt core/shell nanoparticles.
Zhu F; Zhao G; Dou W
Mikrochim Acta; 2018 Sep; 185(10):455. PubMed ID: 30215173
[TBL] [Abstract][Full Text] [Related]
6. An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry.
Serafín V; Torrente-Rodríguez RM; González-Cortés A; García de Frutos P; Sabaté M; Campuzano S; Yáñez-Sedeño P; Pingarrón JM
Talanta; 2018 Mar; 179():131-138. PubMed ID: 29310212
[TBL] [Abstract][Full Text] [Related]
7. Sensitive Impedimetric Immunoassay of Japanese Encephalitis Virus Based on Enzyme Biocatalyzed Precipitation on a Gold Nanoparticle-modified Screen-printed Carbon Electrode.
Geng X; Zhang F; Gao Q; Lei Y
Anal Sci; 2016; 32(10):1105-1109. PubMed ID: 27725612
[TBL] [Abstract][Full Text] [Related]
8. Voltammetric sandwich immunoassay for Cronobacter sakazakii using a screen-printed carbon electrode modified with horseradish peroxidase, reduced graphene oxide, thionine and gold nanoparticles.
Zhu F; Zhao G; Dou W
Mikrochim Acta; 2017 Dec; 185(1):45. PubMed ID: 29594632
[TBL] [Abstract][Full Text] [Related]
9. Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screen-printed carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7.
Lin YH; Chen SH; Chuang YC; Lu YC; Shen TY; Chang CA; Lin CS
Biosens Bioelectron; 2008 Jul; 23(12):1832-7. PubMed ID: 18424027
[TBL] [Abstract][Full Text] [Related]
10. A microfluidic device based on a screen-printed carbon electrode with electrodeposited gold nanoparticles for the detection of IgG anti-Trypanosoma cruzi antibodies.
Pereira SV; Bertolino FA; Fernández-Baldo MA; Messina GA; Salinas E; Sanz MI; Raba J
Analyst; 2011 Nov; 136(22):4745-51. PubMed ID: 21984978
[TBL] [Abstract][Full Text] [Related]
11. Design and development of a highly stable hydrogen peroxide biosensor on screen printed carbon electrode based on horseradish peroxidase bound with gold nanoparticles in the matrix of chitosan.
Tangkuaram T; Ponchio C; Kangkasomboon T; Katikawong P; Veerasai W
Biosens Bioelectron; 2007 Apr; 22(9-10):2071-8. PubMed ID: 17046233
[TBL] [Abstract][Full Text] [Related]
12. Ultrasensitive peptide-based multiplexed electrochemical biosensor for the simultaneous detection of Listeria monocytogenes and Staphylococcus aureus.
Eissa S; Zourob M
Mikrochim Acta; 2020 Aug; 187(9):486. PubMed ID: 32761391
[TBL] [Abstract][Full Text] [Related]
13. Development of amperometric lysine biosensors based on Au nanoparticles/multiwalled carbon nanotubes/polymers modified Au electrodes.
Chauhan N; Singh A; Narang J; Dahiya S; Pundir CS
Analyst; 2012 Nov; 137(21):5113-22. PubMed ID: 22986735
[TBL] [Abstract][Full Text] [Related]
14. An intimately bonded titanate nanotube-polyaniline-gold nanoparticle ternary composite as a scaffold for electrochemical enzyme biosensors.
Liu X; Zhu J; Huo X; Yan R; Wong DKY
Anal Chim Acta; 2016 Mar; 911():59-68. PubMed ID: 26893086
[TBL] [Abstract][Full Text] [Related]
15. Dual-aptamer-based voltammetric biosensor for the Mycobacterium tuberculosis antigen MPT64 by using a gold electrode modified with a peroxidase loaded composite consisting of gold nanoparticles and a Zr(IV)/terephthalate metal-organic framework.
Li N; Huang X; Sun D; Yu W; Tan W; Luo Z; Chen Z
Mikrochim Acta; 2018 Nov; 185(12):543. PubMed ID: 30421038
[TBL] [Abstract][Full Text] [Related]
16. Single cell immunodetection of Escherichia coli O157:H7 on an indium-tin-oxide electrode by using an electrochemical label with an organic-inorganic nanostructure.
Nguyen DQ; Ishiki K; Shiigi H
Mikrochim Acta; 2018 Sep; 185(10):465. PubMed ID: 30225738
[TBL] [Abstract][Full Text] [Related]
17. Optimized dendrimer-encapsulated gold nanoparticles and enhanced carbon nanotube nanoprobes for amplified electrochemical immunoassay of E. coli in dairy product based on enzymatically induced deposition of polyaniline.
Zhang X; Shen J; Ma H; Jiang Y; Huang C; Han E; Yao B; He Y
Biosens Bioelectron; 2016 Jun; 80():666-673. PubMed ID: 26908184
[TBL] [Abstract][Full Text] [Related]
18. Electrochemical determination of Salmonella typhimurium by using aptamer-loaded gold nanoparticles and a composite prepared from a metal-organic framework (type UiO-67) and graphene.
Dai G; Li Z; Luo F; Ai S; Chen B; Wang Q
Mikrochim Acta; 2019 Aug; 186(9):620. PubMed ID: 31410576
[TBL] [Abstract][Full Text] [Related]
19. Silver nanoparticles/multiwalled carbon nanotube/polyaniline film for amperometric glutathione biosensor.
Narang J; Chauhan N; Jain P; Pundir CS
Int J Biol Macromol; 2012 Apr; 50(3):672-8. PubMed ID: 22300999
[TBL] [Abstract][Full Text] [Related]
20. Fabrication of a novel aptasensor based on three-dimensional reduced graphene oxide/polyaniline/gold nanoparticle composite as a novel platform for high sensitive and specific cocaine detection.
Hashemi P; Bagheri H; Afkhami A; Ardakani YH; Madrakian T
Anal Chim Acta; 2017 Dec; 996():10-19. PubMed ID: 29137703
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]