These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 29594841)

  • 1. A two-wavelength fluorescence recovery method for the simultaneous determination of aureomycin and oxytetracycline by using gold nanocrystals modified with serine and 11-mercaptoundecanoic acid.
    Mao Y; Wu Y; Nie Y; Wang J; Liu Y; Xu S; Luo X
    Mikrochim Acta; 2018 Mar; 185(4):222. PubMed ID: 29594841
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Polyethyleneimine capped bimetallic Au/Pt nanoclusters are a viable fluorescent probe for specific recognition of chlortetracycline among other tetracycline antibiotics.
    Xu N; Meng L; Li HW; Lu DY; Wu Y
    Mikrochim Acta; 2018 May; 185(6):294. PubMed ID: 29752570
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel dual ligand co-functionalized fluorescent gold nanoclusters as a versatile probe for sensitive analysis of Hg(2+) and oxytetracycline.
    Xu S; Li X; Mao Y; Gao T; Feng X; Luo X
    Anal Bioanal Chem; 2016 Apr; 408(11):2955-62. PubMed ID: 26597915
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluorescent MUA-stabilized Au nanoclusters for sensitive and selective detection of penicillamine.
    Yu H; Chen X; Yu L; Sun M; Alamry KA; Asiri AM; Zhang K; Zapien JA; Wang S
    Anal Bioanal Chem; 2018 Apr; 410(10):2629-2636. PubMed ID: 29428990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Facile preparation of high-quantum-yield gold nanoclusters: application to probing mercuric ions and biothiols.
    Chang HC; Chang YF; Fan NC; Ho JA
    ACS Appl Mater Interfaces; 2014; 6(21):18824-31. PubMed ID: 25323388
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Gold nanoclusters-Cu(2+) ensemble-based fluorescence turn-on and real-time assay for acetylcholinesterase activity and inhibitor screening.
    Sun J; Yang X
    Biosens Bioelectron; 2015 Dec; 74():177-82. PubMed ID: 26141104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel ratiometric fluorescence probe for highly sensitive and specific detection of chlorotetracycline among tetracycline antibiotics.
    Meng L; Lan C; Liu Z; Xu N; Wu Y
    Anal Chim Acta; 2019 Dec; 1089():144-151. PubMed ID: 31627811
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fluorescent aptasensor for sensitive analysis oxytetracycline based on silver nanoclusters.
    Hosseini M; Mehrabi F; Ganjali MR; Norouzi P
    Luminescence; 2016 Nov; 31(7):1339-1343. PubMed ID: 26899385
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Copper nanoclusters stabilized by D-penicillamine for ultrasensitive and visual detection of oxytetracycline.
    Wang T; Liu W; Tian S; Tian D
    Spectrochim Acta A Mol Biomol Spectrosc; 2023 Apr; 290():122286. PubMed ID: 36592593
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of the activity of telomerase in cancer cells by using BSA-protected gold nanoclusters as a fluorescent probe.
    Xu Y; Zhang P; Wang Z; Lv S; Ding C
    Mikrochim Acta; 2018 Feb; 185(3):198. PubMed ID: 29594751
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluorescent methionine-capped gold nanoclusters for ultra-sensitive determination of copper(II) and cobalt(II), and their use in a test strip.
    Sang F; Zhang X; Shen F
    Mikrochim Acta; 2019 May; 186(6):373. PubMed ID: 31123901
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A biomimetic approach to conjugate vitamin B
    Bothra S; Babu LT; Paira P; Ashok Kumar SK; Kumar R; Sahoo SK
    Anal Bioanal Chem; 2018 Jan; 410(1):201-210. PubMed ID: 29098339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficient On-Off Ratiometric Fluorescence Probe for Cyanide Ion Based on Perturbation of the Interaction between Gold Nanoclusters and a Copper(II)-Phthalocyanine Complex.
    Shojaeifard Z; Hemmateenejad B; Shamsipur M
    ACS Appl Mater Interfaces; 2016 Jun; 8(24):15177-86. PubMed ID: 27211049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluorimetric determination of tetracycline antibiotics in animal derived foods using boron and nitrogen co-doped ceria-based nanoparticles.
    Li Q; Fan P; Hao Z; Ni S; Wu Q; Li L
    Mikrochim Acta; 2024 Feb; 191(3):147. PubMed ID: 38374514
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A ratiometric fluorescent probe for sensitive, selective and reversible detection of copper (II) based on riboflavin-stabilized gold nanoclusters.
    Zhang M; Le HN; Jiang XQ; Guo SM; Yu HJ; Ye BC
    Talanta; 2013 Dec; 117():399-404. PubMed ID: 24209359
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Disassembly mediated fluorescence recovery of gold nanodots for selective sulfide sensing.
    Yuan Z; Peng M; Shi L; Du Y; Cai N; He Y; Chang HT; Yeung ES
    Nanoscale; 2013 Jun; 5(11):4683-6. PubMed ID: 23626986
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Potassium triiodide-quenched gold nanocluster as a fluorescent turn-on probe for sensing cysteine/homocysteine in human serum.
    Nebu J; Anjali Devi JS; Aparna RS; Aswathy B; Lekha GM; Sony G
    Anal Bioanal Chem; 2019 Feb; 411(5):997-1007. PubMed ID: 30637437
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Specific binding and internalization: an investigation of fluorescent aptamer-gold nanoclusters and cells with fluorescence lifetime imaging microscopy.
    Mutas M; Strelow C; Kipp T; Mews A
    Nanoscale; 2018 Nov; 10(43):20453-20461. PubMed ID: 30379177
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Capillary electrophoretic determination of heavy-metal ions using 11-mercaptoundecanoic acid and 6-mercapto-1-hexanol co-functionalized gold nanoparticle as colorimetric probe.
    Bi J; Li T; Ren H; Ling R; Wu Z; Qin W
    J Chromatogr A; 2019 Jun; 1594():208-215. PubMed ID: 30772060
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Methionine-directed fabrication of gold nanoclusters with yellow fluorescent emission for Cu(2+) sensing.
    Deng HH; Zhang LN; He SB; Liu AL; Li GW; Lin XH; Xia XH; Chen W
    Biosens Bioelectron; 2015 Mar; 65():397-403. PubMed ID: 25461187
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.