340 related articles for article (PubMed ID: 29595322)
41. Efficacy and Safety of Cone-Beam Computed Tomography-Derived Augmented Fluoroscopy Combined with Endobronchial Ultrasound in Peripheral Pulmonary Lesions.
Yu KL; Yang SM; Ko HJ; Tsai HY; Ko JC; Lin CK; Ho CC; Shih JY
Respiration; 2021; 100(6):538-546. PubMed ID: 33845482
[TBL] [Abstract][Full Text] [Related]
42. Percutaneous transthoracic localization of pulmonary nodules under C-arm cone-beam CT virtual navigation guidance.
Kim TH; Park CM; Lee SM; McAdams HP; Kim YT; Goo JM
Diagn Interv Radiol; 2016; 22(3):224-30. PubMed ID: 27015318
[TBL] [Abstract][Full Text] [Related]
43. Cumulative experience of preoperative real-time augmented fluoroscopy-guided endobronchial dye marking for small pulmonary nodules: An analysis of 30 initial patients.
Yang SM; Yu KL; Lin JH; Lin KH; Liu YL; Sun SE; Meng LH; Ko HJ
J Formos Med Assoc; 2019 Aug; 118(8):1232-1238. PubMed ID: 31097282
[TBL] [Abstract][Full Text] [Related]
44. Is Free Breathing Possible During Computed Tomography-Guided Percutaneous Transthoracic Lung Biopsy? The Clinical Experience in 585 Cases.
Han JY; Lee KN; Choi SJ; Baek JW; Kim D; Lee H; Yoon YS; Choo HJ; Heo YJ; Park J; Kim DH
J Comput Assist Tomogr; 2022 Mar-Apr 01; 46(2):294-299. PubMed ID: 35297585
[TBL] [Abstract][Full Text] [Related]
45. C-arm cone-beam computed tomography with stereotactic needle guidance for percutaneous adrenal biopsy: initial experience.
Jiao D; Xie N; Wu G; Ren J; Han X
Acta Radiol; 2017 May; 58(5):617-624. PubMed ID: 27552980
[TBL] [Abstract][Full Text] [Related]
46. Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules.
Yang W; Sun W; Li Q; Yao Y; Lv T; Zeng J; Liang W; Zhou X; Song Y
PLoS One; 2015; 10(6):e0131373. PubMed ID: 26110775
[TBL] [Abstract][Full Text] [Related]
47. Accuracy and complications of CT-guided pulmonary core biopsy in small nodules: a single-center experience.
Huang MD; Weng HH; Hsu SL; Hsu LS; Lin WM; Chen CW; Tsai YH
Cancer Imaging; 2019 Jul; 19(1):51. PubMed ID: 31337425
[TBL] [Abstract][Full Text] [Related]
48. Learning Curve for CT-Guided Percutaneous Transthoracic Needle Biopsy: Retrospective Evaluation Among 17 Thoracic Imaging Fellows at a Tertiary Referral Hospital.
Park R; Lee SM; Kim S; Park S; Choe J; Do KH; Seo JB
AJR Am J Roentgenol; 2022 Jan; 218(1):112-123. PubMed ID: 34406052
[No Abstract] [Full Text] [Related]
49. Clinical role, safety and diagnostic accuracy of percutaneous transthoracic needle biopsy in the evaluation of pulmonary consolidation.
Kiranantawat N; McDermott S; Fintelmann FJ; Montesi SB; Price MC; Digumarthy SR; Sharma A
Respir Res; 2019 Jan; 20(1):23. PubMed ID: 30704502
[TBL] [Abstract][Full Text] [Related]
50. Efficacy and Safety of Cone-Beam CT Augmented Electromagnetic Navigation Guided Bronchoscopic Biopsies of Indeterminate Pulmonary Nodules.
Podder S; Chaudry S; Singh H; Jondall EM; Kurman JS; Benn BS
Tomography; 2022 Aug; 8(4):2049-2058. PubMed ID: 36006070
[TBL] [Abstract][Full Text] [Related]
51. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.
Bhatt KM; Tandon YK; Graham R; Lau CT; Lempel JK; Azok JT; Mazzone PJ; Schneider E; Obuchowski NA; Bolen MA
Radiology; 2018 Mar; 286(3):1052-1061. PubMed ID: 29156147
[TBL] [Abstract][Full Text] [Related]
52. Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.
Choi MJ; Kim Y; Hong YS; Shim SS; Lim SM; Lee JK
Br J Radiol; 2012 Jun; 85(1014):e182-7. PubMed ID: 21791505
[TBL] [Abstract][Full Text] [Related]
53. Accuracy and complications of percutaneous transthoracic needle lung biopsy for the diagnosis of malignancy in patients with idiopathic pulmonary fibrosis.
Shin YJ; Yun G; Yoon SH; Song H; Kim J; Kim J; Park JS; Lee KW; Lee KH
Eur Radiol; 2021 Dec; 31(12):9000-9011. PubMed ID: 34003347
[TBL] [Abstract][Full Text] [Related]
54. Cone-beam computed tomography image-guided percutaneous microwave ablation for lung nodules in a hybrid operating room: an initial experience.
Chang LK; Yang SM; Chung WY; Chen LC; Chang HC; Ho MC; Chang YC; Yu CJ
Eur Radiol; 2024 May; 34(5):3309-3319. PubMed ID: 37926741
[TBL] [Abstract][Full Text] [Related]
55. C-Arm Cone-Beam CT Virtual Navigation versus Conventional CT Guidance in the Transthoracic Lung Biopsy: A Case-Control Study.
Yang L; Wang Y; Li L; Liu D; Wu X; Zhang W; Pan F; Liang H; Zheng C
Diagnostics (Basel); 2022 Jan; 12(1):. PubMed ID: 35054282
[TBL] [Abstract][Full Text] [Related]
56. Cone-Beam CT Virtual Navigation-Guided Percutaneous Needle Biopsy of Suspicious Pleural Metastasis: A Pilot Study.
Lim HJ; Park CM; Yoon SH; Bae JS; Goo JM
Korean J Radiol; 2018; 19(5):872-879. PubMed ID: 30174476
[TBL] [Abstract][Full Text] [Related]
57. Computed tomography-guided percutaneous needle biopsy of pulmonary nodules: impact of nodule size on diagnostic accuracy.
Kothary N; Lock L; Sze DY; Hofmann LV
Clin Lung Cancer; 2009 Sep; 10(5):360-3. PubMed ID: 19808195
[TBL] [Abstract][Full Text] [Related]
58. Computed tomography-guided percutaneous cutting needle biopsy for small (≤ 20 mm) lung nodules.
Li GC; Fu YF; Cao W; Shi YB; Wang T
Medicine (Baltimore); 2017 Nov; 96(46):e8703. PubMed ID: 29145307
[TBL] [Abstract][Full Text] [Related]
59. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules.
Li H; Boiselle PM; Shepard JO; Trotman-Dickenson B; McLoud TC
AJR Am J Roentgenol; 1996 Jul; 167(1):105-9. PubMed ID: 8659351
[TBL] [Abstract][Full Text] [Related]
60. Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.
Jin KN; Park CM; Goo JM; Lee HJ; Lee Y; Kim JI; Choi SY; Kim HC
Eur Radiol; 2010 Sep; 20(9):2108-15. PubMed ID: 20393715
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]