These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 29604949)

  • 1. Reuse of Single-Use HemaClear Exsanguination Tourniquets: A Technique Note.
    Franzone JM; Yang JH; Herzenberg JE
    J Long Term Eff Med Implants; 2017; 27(1):59-65. PubMed ID: 29604949
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Narrow elastic disposable tourniquet (Hemaclear®) vs. traditional wide pneumatic tourniquet for creation or revision of hemodialysis angioaccesses.
    Bourquelot P; Levy BI
    J Vasc Access; 2016 May; 17(3):205-9. PubMed ID: 27056025
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulmonary Embolism After Application of a Sterile Elastic Exsanguination Tourniquet.
    Feldman V; Biadsi A; Slavin O; Kish B; Tauber I; Nyska M; Brin YS
    Orthopedics; 2015 Dec; 38(12):e1160-3. PubMed ID: 26652340
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a new tourniquet for hand surgery: Comparison of 76 carpal tunnel syndrome cases operated using a Hemaclear(®) Model-F tourniquet versus a pneumatic tourniquet.
    Pereira A; Hendriks S; Facca S; Bodin F; Gay A; Liverneaux P
    Chir Main; 2015 Apr; 34(2):73-8. PubMed ID: 25772086
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The silicone ring tourniquet in orthopaedic operations of the extremities.
    Drosos GI; Ververidis A; Mavropoulos R; Vastardis G; Tsioros KI; Kazakos K
    Surg Technol Int; 2013 Sep; 23():251-7. PubMed ID: 23860930
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pain and paraesthesia produced by silicone ring and pneumatic tourniquets.
    Mohan A; Baskaradas A; Solan M; Magnussen P
    J Hand Surg Eur Vol; 2011 Mar; 36(3):215-8. PubMed ID: 21131688
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel elastic exsanguination tourniquet as an alternative to the pneumatic cuff in pediatric orthopedic limb surgery.
    Eidelman M; Katzman A; Bialik V
    J Pediatr Orthop B; 2006 Sep; 15(5):379-84. PubMed ID: 16891968
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of a new exsanguination tourniquet in internal fixation of distal radius fractures.
    Norman D; Greenfield I; Ghrayeb N; Peled E; Dayan L
    Tech Hand Up Extrem Surg; 2009 Dec; 13(4):173-5. PubMed ID: 19956041
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluating Tourniquet Efficacy Comparing Exsanguination Techniques for the Upper Extremity.
    Goodwin TM; Davies JP; Jackson JB; Millikin M; Walsh JJ
    Orthop Nurs; 2021 Mar-Apr 01; 40(2):89-93. PubMed ID: 33756536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Auto-transfusion tourniquets: the next evolution of tourniquets.
    Tang DH; Olesnicky BT; Eby MW; Heiskell LE
    Open Access Emerg Med; 2013; 5():29-32. PubMed ID: 27147871
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical utilization of arterial occlusion pressure estimation method in lower limb surgery: effectiveness of tourniquet pressures.
    Tuncalı B; Boya H; Kayhan Z; Araç Ş; Çamurdan MA
    Acta Orthop Traumatol Turc; 2016; 50(2):171-7. PubMed ID: 26969952
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 'The BloodStopper' - experiences with a novel portable hand-held orthopaedic limb tourniquet.
    Millar TM; McGrath P; McConnachie CC
    Trop Doct; 2007 Oct; 37(4):202-3. PubMed ID: 17988474
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Sterile Elastic Exsanguination Tourniquet vs. the Pneumatic Tourniquet for Total Knee Arthroplasty.
    Brin YS; Feldman V; Ron Gal I; Markushevitch M; Regev A; Stern A
    J Arthroplasty; 2015 Apr; 30(4):595-9. PubMed ID: 25496927
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of sterile versus non-sterile tourniquets on microbiological colonisation in lower limb surgery.
    Thompson SM; Middleton M; Farook M; Cameron-Smith A; Bone S; Hassan A
    Ann R Coll Surg Engl; 2011 Nov; 93(8):589-90. PubMed ID: 22041233
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does knee position at the time of tourniquet inflation affect knee range of motion?
    Zura RD; Adams SB; Mata BA; Pietrobon R; Olson SA
    J Surg Orthop Adv; 2007; 16(4):171-3. PubMed ID: 18053398
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preliminary Comparison of Pneumatic Models of Tourniquet for Prehospital Control of Limb Bleeding in a Manikin Model.
    Gibson R; Aden JK; Dubick MA; Kragh JF
    J Spec Oper Med; 2016; 16(2):21-7. PubMed ID: 27450599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Back to Basics: Pneumatic Tourniquet Use.
    Spruce L
    AORN J; 2017 Sep; 106(3):219-226. PubMed ID: 28865632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The new digit tourniquet ForgetMeNot
    Hidalgo Díaz JJ; Muresan L; Touchal S; Bahlouli N; Liverneaux P; Facca S
    Orthop Traumatol Surg Res; 2018 Feb; 104(1):133-136. PubMed ID: 29233761
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Timing of antibiotic prophylaxis in tourniquet surgery.
    Akinyoola AL; Adegbehingbe OO; Odunsi A
    J Foot Ankle Surg; 2011; 50(4):374-6. PubMed ID: 21596588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The use of lower tourniquet inflation pressures in extremity surgery facilitated by curved and wide tourniquets and an integrated cuff inflation system.
    Pedowitz RA; Gershuni DH; Botte MJ; Kuiper S; Rydevik BL; Hargens AR
    Clin Orthop Relat Res; 1993 Feb; (287):237-44. PubMed ID: 8448950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.