BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 29605551)

  • 1. Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?
    Ceriotti F
    Clin Biochem; 2018 Jul; 57():37-40. PubMed ID: 29605551
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An approach for estimating measurement uncertainty in medical laboratories using data from long-term quality control and external quality assessment schemes.
    Padoan A; Antonelli G; Aita A; Sciacovelli L; Plebani M
    Clin Chem Lab Med; 2017 Oct; 55(11):1696-1701. PubMed ID: 28245184
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Different top-down approaches to estimate measurement uncertainty of whole blood tacrolimus mass concentration values.
    Rigo-Bonnin R; Blanco-Font A; Canalias F
    Clin Biochem; 2018 Jul; 57():56-61. PubMed ID: 29750938
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measuring Analytical Quality: Total Analytical Error Versus Measurement Uncertainty.
    Westgard JO; Westgard SA
    Clin Lab Med; 2017 Mar; 37(1):1-13. PubMed ID: 28153359
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The top-down approach to measurement uncertainty: which formula should we use in laboratory medicine?
    Martinello F; Snoj N; Skitek M; Jerin A
    Biochem Med (Zagreb); 2020 Jun; 30(2):020101. PubMed ID: 32292278
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement uncertainty of γ-glutamyltransferase (GGT) in human serum by four approaches using different quality assessment data.
    Zhou R; Qin Y; Yin H; Yang Y; Wang Q
    Clin Chem Lab Med; 2018 Jan; 56(2):242-248. PubMed ID: 28809749
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement uncertainty in laboratory reports: A tool for improving the interpretation of test results.
    Padoan A; Sciacovelli L; Aita A; Antonelli G; Plebani M
    Clin Biochem; 2018 Jul; 57():41-47. PubMed ID: 29548924
    [TBL] [Abstract][Full Text] [Related]  

  • 8. IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical Samples.
    Nilsson G; Budd JR; Greenberg N; Delatour V; Rej R; Panteghini M; Ceriotti F; Schimmel H; Weykamp C; Keller T; Camara JE; Burns C; Vesper HW; MacKenzie F; Miller WG;
    Clin Chem; 2018 Mar; 64(3):455-464. PubMed ID: 29348165
    [TBL] [Abstract][Full Text] [Related]  

  • 9. What information on measurement uncertainty should be communicated to clinicians, and how?
    Plebani M; Sciacovelli L; Bernardi D; Aita A; Antonelli G; Padoan A
    Clin Biochem; 2018 Jul; 57():18-22. PubMed ID: 29402416
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Description of a generally applicable model for the evaluation of uncertainty of measurement in clinical chemistry.
    Kristiansen J
    Clin Chem Lab Med; 2001 Oct; 39(10):920-31. PubMed ID: 11758604
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement uncertainty in clinical chemistry: ISO 20914 versus nordtest or intermediate precision versus bias.
    Nurlu N; Cat A; Ucar KT
    Scand J Clin Lab Invest; 2024 May; 84(3):147-153. PubMed ID: 38742707
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A bottom-up approach in estimating the measurement uncertainty and other important considerations for quantitative analyses in drug testing for horses.
    Leung GN; Ho EN; Kwok WH; Leung DK; Tang FP; Wan TS; Wong AS; Wong CH; Wong JK; Yu NH
    J Chromatogr A; 2007 Sep; 1163(1-2):237-46. PubMed ID: 17628571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimates of measurement uncertainty from proficiency testing schemes, internal laboratory quality monitoring and during routine enforcement examination of foods.
    Jarvis B; Corry JE; Hedges AJ
    J Appl Microbiol; 2007 Aug; 103(2):462-7. PubMed ID: 17650207
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The estimation of uncertainty of measurement of glycated hemoglobin as an analytical performance specification and in the interpretation of its results.
    Galindo-Méndez M; Sánchez-López A; Cruz-Fuentes L
    Clin Biochem; 2019 Jan; 63():92-96. PubMed ID: 30595159
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Requirements for reproducibility, trueness and error of measurement in internal quality control schemes.
    Bonvicini P; Metus P; Pavón MA; Tocchini M
    Clin Chem Lab Med; 2003 May; 41(5):693-9. PubMed ID: 12812269
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Issues in assessing analytical performance specifications in healthcare systems assembling multiple laboratories and measuring systems.
    Theodorsson E
    Clin Chem Lab Med; 2024 Jul; 62(8):1520-1530. PubMed ID: 38329003
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Managing quality vs. measuring uncertainty in the medical laboratory.
    Westgard JO
    Clin Chem Lab Med; 2010; 48(1):31-40. PubMed ID: 19919330
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Uncertainty of measurement].
    Giroud C; Arnaud J; Vassault A;
    Ann Biol Clin (Paris); 2010 Dec; 68 Spec No 1():237-45. PubMed ID: 21613020
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simplified approach to uncertainty of measurement in the clinical virology laboratory.
    Newman H; Tshisevhe V
    Rev Med Virol; 2018 Nov; 28(6):e2006. PubMed ID: 30112776
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The role of External Quality Assessment Schemes in monitoring and improving the standardization process.
    Ceriotti F
    Clin Chim Acta; 2014 May; 432():77-81. PubMed ID: 24389052
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.