These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 29609341)

  • 1. Dielectrophoresis-actuated in-plane optofluidic lens with tunability of focal length from negative to positive.
    Chen Q; Li T; Zhu Y; Yu W; Zhang X
    Opt Express; 2018 Mar; 26(6):6532-6541. PubMed ID: 29609341
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dielectrophoresis-actuated liquid lenses with dual air/liquid interfaces tuned from biconcave to biconvex.
    Chen Q; Li T; Li Z; Lu C; Zhang X
    Lab Chip; 2018 Dec; 18(24):3849-3854. PubMed ID: 30420975
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and characteristics of tunable in-plane optofluidic lens actuated by viscous force.
    Zhang H; Zhang Z; Song X; Zhao R; Zhang Z; Jia D; Liu T
    Opt Lett; 2021 Aug; 46(16):4017-4020. PubMed ID: 34388800
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aberration-free aspherical in-plane tunable liquid lenses by regulating local curvatures.
    Chen Q; Tong X; Zhu Y; Tsoi CC; Jia Y; Li Z; Zhang X
    Lab Chip; 2020 Mar; 20(5):995-1001. PubMed ID: 32025666
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optofluidic tunable lenses using laser-induced thermal gradient.
    Chen Q; Jian A; Li Z; Zhang X
    Lab Chip; 2016 Jan; 16(1):104-11. PubMed ID: 26584422
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adaptive liquid crystal lens with large focal length tunability.
    Ren H; Wu ST
    Opt Express; 2006 Nov; 14(23):11292-8. PubMed ID: 19529544
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optofluidic variable-focus lenses for light manipulation.
    Seow YC; Lim SP; Lee HP
    Lab Chip; 2012 Oct; 12(19):3810-5. PubMed ID: 22885654
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrically Tunable Lenses for Imaging and Light Manipulation.
    Chen L; Liang S; Chen Z; Liang X; Chen Q
    Micromachines (Basel); 2023 Jan; 14(2):. PubMed ID: 36838021
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hybrid driving variable-focus optofluidic lens.
    Wang JH; Tang WP; Li LY; Xiao L; Zhou X; Wang QH
    Opt Express; 2019 Nov; 27(24):35203-35215. PubMed ID: 31878693
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-Performance PVC Gel for Adaptive Micro-Lenses with Variable Focal Length.
    Bae JW; Shin EJ; Jeong J; Choi DS; Lee JE; Nam BU; Lin L; Kim SY
    Sci Rep; 2017 May; 7(1):2068. PubMed ID: 28522844
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optofluidic Tunable Lenses for In-Plane Light Manipulation.
    Chen Q; Li T; Li Z; Long J; Zhang X
    Micromachines (Basel); 2018 Feb; 9(3):. PubMed ID: 30424031
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Focal-length-tunable elastomer-based liquid-filled plano-convex mini lens.
    Fang C; Dai B; Zhuo R; Yuan X; Gao X; Wen J; Sheng B; Zhang D
    Opt Lett; 2016 Jan; 41(2):404-7. PubMed ID: 26766725
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental study of dielectrophoresis and liquid dielectrophoresis mechanisms for particle capture in a droplet.
    Tsai SL; Hong JL; Chen MK; Jang LS
    Electrophoresis; 2011 Jun; 32(11):1337-47. PubMed ID: 21538398
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optofluidic lenses with horizontal-to-vertical aspect ratios in the subunit regime.
    Prasad S; Del Rosso M; Vale JR; Collier CM
    Appl Opt; 2018 Jul; 57(19):5474-5482. PubMed ID: 30117843
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tunable Liquid Gradient Refractive Index (L-GRIN) lens with two degrees of freedom.
    Mao X; Lin SC; Lapsley MI; Shi J; Juluri BK; Huang TJ
    Lab Chip; 2009 Jul; 9(14):2050-8. PubMed ID: 19568674
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-step manipulations of PMMA submicron particles using dielectrophoresis.
    Chuang CH; Huang YW
    Electrophoresis; 2013 Dec; 34(22-23):3111-8. PubMed ID: 24038067
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optofluidic tunable microlens by manipulating the liquid meniscus using a flared microfluidic structure.
    Mao X; Stratton ZI; Nawaz AA; Lin SC; Huang TJ
    Biomicrofluidics; 2010 Dec; 4(4):43007. PubMed ID: 21267439
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optofluidic lens with low spherical and low field curvature aberrations.
    Zhao HT; Yang Y; Chin LK; Chen HF; Zhu WM; Zhang JB; Yap PH; Liedberg B; Wang K; Wang G; Ser W; Liu AQ
    Lab Chip; 2016 Apr; 16(9):1617-24. PubMed ID: 27050492
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optofluidic lens based on electrowetting liquid piston.
    Li LY; Yuan RY; Wang JH; Li L; Wang QH
    Sci Rep; 2019 Sep; 9(1):13062. PubMed ID: 31506551
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An electrokinetically tunable optofluidic bi-concave lens.
    Li H; Song C; Luong TD; Nguyen NT; Wong TN
    Lab Chip; 2012 Oct; 12(19):3680-7. PubMed ID: 22777136
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.