These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 29609819)

  • 1. Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy.
    Alsanea F; Wootton L; Sahoo N; Kudchadker R; Mahmood U; Beddar S
    Phys Med; 2018 Mar; 47():58-63. PubMed ID: 29609819
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.
    Wootton L; Holmes C; Sahoo N; Beddar S
    Phys Med Biol; 2015 Feb; 60(3):1185-98. PubMed ID: 25591037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of the exradin W1 plastic scintillation detector for small field applications in proton therapy.
    Hoehr C; Lindsay C; Beaudry J; Penner C; Strgar V; Lee R; Duzenli C
    Phys Med Biol; 2018 May; 63(9):095016. PubMed ID: 29634488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry.
    Galavis PE; Hu L; Holmes S; Das IJ
    Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.
    Pasquino M; Cutaia C; Radici L; Valzano S; Gino E; Cavedon C; Stasi M
    Br J Radiol; 2017 Jan; 90(1069):20160596. PubMed ID: 27826990
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams.
    Wang LL; Perles LA; Archambault L; Sahoo N; Mirkovic D; Beddar S
    Phys Med Biol; 2012 Dec; 57(23):7767-81. PubMed ID: 23128412
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
    Papaconstadopoulos P; Archambault L; Seuntjens J
    Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
    Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
    Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quality assurance for Gamma Knife Perfexion using the Exradin W1 plastic scintillation detector and Lucy phantom.
    Therriault-Proulx F; Pino R; Yang JN; Beddar AS
    Phys Med Biol; 2019 Nov; 64(22):225007. PubMed ID: 31581139
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical Note: Evaluation of plastic scintillator detector for small field stereotactic patient-specific quality assurance.
    Qin Y; Gardner SJ; Kim J; Huang Y; Wen N; Doemer A; Chetty IJ
    Med Phys; 2017 Oct; 44(10):5509-5516. PubMed ID: 28714067
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Small field dose measurements using plastic scintillation detector in heterogeneous media.
    Xue J; McKay JD; Grimm J; Cheng CW; Berg R; Grimm SL; Xu Q; Subedi G; Das IJ
    Med Phys; 2017 Jul; 44(7):3815-3820. PubMed ID: 28398596
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.
    Klein DM; Tailor RC; Archambault L; Wang L; Therriault-Proulx F; Beddar AS
    Med Phys; 2010 Oct; 37(10):5541-9. PubMed ID: 21089789
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
    Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
    Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using a small-core graphite calorimeter for dosimetry and scintillator quenching corrections in a therapeutic proton beam.
    Christensen JB; Vestergaard A; Andersen CE
    Phys Med Biol; 2020 Nov; 65(21):215023. PubMed ID: 32526719
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The practical application of scintillation dosimetry in small-field photon-beam radiotherapy.
    Burke E; Poppinga D; Schönfeld AA; Harder D; Poppe B; Looe HK
    Z Med Phys; 2017 Dec; 27(4):324-333. PubMed ID: 28342596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Characterization of Small Volume Plastic Scintillation Detector].
    Fukui Y; Hamada Y; Noma K; Harada N
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer.
    Wootton L; Kudchadker R; Lee A; Beddar S
    Phys Med Biol; 2014 Feb; 59(3):647-60. PubMed ID: 24434775
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.