BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 29609819)

  • 1. Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy.
    Alsanea F; Wootton L; Sahoo N; Kudchadker R; Mahmood U; Beddar S
    Phys Med; 2018 Mar; 47():58-63. PubMed ID: 29609819
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.
    Wootton L; Holmes C; Sahoo N; Beddar S
    Phys Med Biol; 2015 Feb; 60(3):1185-98. PubMed ID: 25591037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of the exradin W1 plastic scintillation detector for small field applications in proton therapy.
    Hoehr C; Lindsay C; Beaudry J; Penner C; Strgar V; Lee R; Duzenli C
    Phys Med Biol; 2018 May; 63(9):095016. PubMed ID: 29634488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry.
    Galavis PE; Hu L; Holmes S; Das IJ
    Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.
    Pasquino M; Cutaia C; Radici L; Valzano S; Gino E; Cavedon C; Stasi M
    Br J Radiol; 2017 Jan; 90(1069):20160596. PubMed ID: 27826990
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams.
    Wang LL; Perles LA; Archambault L; Sahoo N; Mirkovic D; Beddar S
    Phys Med Biol; 2012 Dec; 57(23):7767-81. PubMed ID: 23128412
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
    Papaconstadopoulos P; Archambault L; Seuntjens J
    Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
    Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
    Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quality assurance for Gamma Knife Perfexion using the Exradin W1 plastic scintillation detector and Lucy phantom.
    Therriault-Proulx F; Pino R; Yang JN; Beddar AS
    Phys Med Biol; 2019 Nov; 64(22):225007. PubMed ID: 31581139
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical Note: Evaluation of plastic scintillator detector for small field stereotactic patient-specific quality assurance.
    Qin Y; Gardner SJ; Kim J; Huang Y; Wen N; Doemer A; Chetty IJ
    Med Phys; 2017 Oct; 44(10):5509-5516. PubMed ID: 28714067
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Small field dose measurements using plastic scintillation detector in heterogeneous media.
    Xue J; McKay JD; Grimm J; Cheng CW; Berg R; Grimm SL; Xu Q; Subedi G; Das IJ
    Med Phys; 2017 Jul; 44(7):3815-3820. PubMed ID: 28398596
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.
    Klein DM; Tailor RC; Archambault L; Wang L; Therriault-Proulx F; Beddar AS
    Med Phys; 2010 Oct; 37(10):5541-9. PubMed ID: 21089789
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
    Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
    Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using a small-core graphite calorimeter for dosimetry and scintillator quenching corrections in a therapeutic proton beam.
    Christensen JB; Vestergaard A; Andersen CE
    Phys Med Biol; 2020 Nov; 65(21):215023. PubMed ID: 32526719
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The practical application of scintillation dosimetry in small-field photon-beam radiotherapy.
    Burke E; Poppinga D; Schönfeld AA; Harder D; Poppe B; Looe HK
    Z Med Phys; 2017 Dec; 27(4):324-333. PubMed ID: 28342596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.
    Therriault-Proulx F; Wootton L; Beddar S
    Phys Med Biol; 2015 Oct; 60(20):7927-39. PubMed ID: 26407188
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Characterization of Small Volume Plastic Scintillation Detector].
    Fukui Y; Hamada Y; Noma K; Harada N
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer.
    Wootton L; Kudchadker R; Lee A; Beddar S
    Phys Med Biol; 2014 Feb; 59(3):647-60. PubMed ID: 24434775
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.