BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

561 related articles for article (PubMed ID: 29616662)

  • 1. Monte Carlo proton dose calculations using a radiotherapy specific dual-energy CT scanner for tissue segmentation and range assessment.
    Almeida IP; Schyns LEJR; Vaniqui A; van der Heyden B; Dedes G; Resch AF; Kamp F; Zindler JD; Parodi K; Landry G; Verhaegen F
    Phys Med Biol; 2018 May; 63(11):115008. PubMed ID: 29616662
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT images.
    Hudobivnik N; Schwarz F; Johnson T; Agolli L; Dedes G; Tessonnier T; Verhaegen F; Thieke C; Belka C; Sommer WH; Parodi K; Landry G
    Med Phys; 2016 Jan; 43(1):495. PubMed ID: 26745942
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning.
    Zhu J; Penfold SN
    Med Phys; 2016 Jun; 43(6):2845-2854. PubMed ID: 27277033
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric impact of dual-energy CT tissue segmentation for low-energy prostate brachytherapy: a Monte Carlo study.
    Remy C; Lalonde A; Béliveau-Nadeau D; Carrier JF; Bouchard H
    Phys Med Biol; 2018 Jan; 63(2):025013. PubMed ID: 29260727
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison study between single- and dual-energy CT density extraction methods for neurological proton monte carlo treatment planning.
    van der Heyden B; Almeida IP; Vilches-Freixas G; Van Beveren C; Vaniqui A; Ares C; Terhaag K; Fonseca GP; Eekers DBP; Verhaegen F
    Acta Oncol; 2020 Feb; 59(2):171-179. PubMed ID: 31646923
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The impact of dual energy CT imaging on dose calculations for pre-clinical studies.
    Vaniqui A; Schyns LEJR; Almeida IP; van der Heyden B; van Hoof SJ; Verhaegen F
    Radiat Oncol; 2017 Nov; 12(1):181. PubMed ID: 29157265
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulation study on potential accuracy gains from dual energy CT tissue segmentation for low-energy brachytherapy Monte Carlo dose calculations.
    Landry G; Granton PV; Reniers B; Ollers MC; Beaulieu L; Wildberger JE; Verhaegen F
    Phys Med Biol; 2011 Oct; 56(19):6257-78. PubMed ID: 21896967
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The impact of dual- and multi-energy CT on proton pencil beam range uncertainties: a Monte Carlo study.
    Lalonde A; Simard M; Remy C; Bär E; Bouchard H
    Phys Med Biol; 2018 Sep; 63(19):195012. PubMed ID: 30183681
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy.
    Dedes G; Dickmann J; Niepel K; Wesp P; Johnson RP; Pankuch M; Bashkirov V; Rit S; Volz L; Schulte RW; Landry G; Parodi K
    Phys Med Biol; 2019 Aug; 64(16):165002. PubMed ID: 31220814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Learning-based synthetic dual energy CT imaging from single energy CT for stopping power ratio calculation in proton radiation therapy.
    Charyyev S; Wang T; Lei Y; Ghavidel B; Beitler JJ; McDonald M; Curran WJ; Liu T; Zhou J; Yang X
    Br J Radiol; 2022 Jan; 95(1129):20210644. PubMed ID: 34709948
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical Note: Relative proton stopping power estimation from virtual monoenergetic images reconstructed from dual-layer computed tomography.
    Landry G; Dörringer F; Si-Mohamed S; Douek P; Abascal JFPJ; Peyrin F; Almeida IP; Verhaegen F; Rinaldi I; Parodi K; Rit S
    Med Phys; 2019 Apr; 46(4):1821-1828. PubMed ID: 30695108
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations.
    Bazalova M; Carrier JF; Beaulieu L; Verhaegen F
    Phys Med Biol; 2008 May; 53(9):2439-56. PubMed ID: 18421124
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of intravenous contrast agent on dose calculation in proton therapy using dual energy CT.
    Lalonde A; Xie Y; Burgdorf B; O'Reilly S; Ingram WS; Yin L; Zou W; Dong L; Bouchard H; Teo BK
    Phys Med Biol; 2019 Jun; 64(12):125024. PubMed ID: 31044743
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tissue decomposition from dual energy CT data for MC based dose calculation in particle therapy.
    Hünemohr N; Paganetti H; Greilich S; Jäkel O; Seco J
    Med Phys; 2014 Jun; 41(6):061714. PubMed ID: 24877809
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved dose calculation accuracy for low energy brachytherapy by optimizing dual energy CT imaging protocols for noise reduction using sinogram affirmed iterative reconstruction.
    Landry G; Gaudreault M; van Elmpt W; Wildberger JE; Verhaegen F
    Z Med Phys; 2016 Mar; 26(1):75-87. PubMed ID: 26422576
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.
    Côté N; Bedwani S; Carrier JF
    Med Phys; 2016 May; 43(5):2611. PubMed ID: 27147370
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental validation of two dual-energy CT methods for proton therapy using heterogeneous tissue samples.
    Bär E; Lalonde A; Zhang R; Jee KW; Yang K; Sharp G; Liu B; Royle G; Bouchard H; Lu HM
    Med Phys; 2018 Jan; 45(1):48-59. PubMed ID: 29134674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of single- and dual-energy CT brain tissue segmentation to PET monitoring of proton therapy.
    Berndt B; Landry G; Schwarz F; Tessonnier T; Kamp F; Dedes G; Thieke C; Würl M; Kurz C; Ganswindt U; Verhaegen F; Debus J; Belka C; Sommer W; Reiser M; Bauer J; Parodi K
    Phys Med Biol; 2017 Mar; 62(6):2427-2448. PubMed ID: 28182581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.
    Hansen DC; Seco J; Sørensen TS; Petersen JB; Wildberger JE; Verhaegen F; Landry G
    Acta Oncol; 2015; 54(9):1638-42. PubMed ID: 26219959
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Proton dose calculation based on converting dual-energy CT data to stopping power ratio (DEEDZ-SPR): a beam-hardening assessment.
    Tanaka S; Noto Y; Utsunomiya S; Yoshimura T; Matsuura T; Saito M
    Phys Med Biol; 2020 Dec; 65(23):235046. PubMed ID: 33336651
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.