BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 29617039)

  • 21. Comparison of Knotless Barbed Suture Versus Monofilament Suture in the Oral Cavity of Cats.
    Durand CL
    J Vet Dent; 2017 Sep; 34(3):148-154. PubMed ID: 28635369
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intestinal dehiscence and mortality in cats undergoing gastrointestinal surgery.
    Hiebert EC; Barry SL; Sawyere DM; DeMonaco SM; Muro NM
    J Feline Med Surg; 2022 Aug; 24(8):779-786. PubMed ID: 34663127
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Subcuticular sutures versus staples for skin closure after open gastrointestinal surgery: a phase 3, multicentre, open-label, randomised controlled trial.
    Tsujinaka T; Yamamoto K; Fujita J; Endo S; Kawada J; Nakahira S; Shimokawa T; Kobayashi S; Yamasaki M; Akamaru Y; Miyamoto A; Mizushima T; Shimizu J; Umeshita K; Ito T; Doki Y; Mori M;
    Lancet; 2013 Sep; 382(9898):1105-12. PubMed ID: 24075050
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Closure of the rectus sheath with a continuous looped suture and the skin with staples in dogs: speed, safety, and costs compared to closure of the rectus sheath with interrupted sutures and the skin with a continuous subdermal suture.
    Kummeling A; van Sluijs FJ
    Vet Q; 1998 Oct; 20(4):126-30. PubMed ID: 9810626
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Staples for wound closure: a controlled trial.
    Gatt D; Quick CR; Owen-Smith MS
    Ann R Coll Surg Engl; 1985 Sep; 67(5):318-20. PubMed ID: 3901864
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Metal staples versus conventional suture for wound closure in total knee arthroplasty].
    Hlubek R; Walder P; Káňa J; Salounová D
    Acta Chir Orthop Traumatol Cech; 2014; 81(3):233-7. PubMed ID: 24945393
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The application of the V-Loc closure device for gastrointestinal sutures: a preliminary study.
    Nemecek E; Negrin L; Beran C; Nemecek R; Hollinsky C
    Surg Endosc; 2013 Oct; 27(10):3830-4. PubMed ID: 23644839
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Staple versus suture closure for ankle fracture fixation: Retrospective chart review for safety and outcomes.
    Lehtonen E; Patel H; Phillips S; Correia Pinto M; Naranje S; Shah A
    Foot (Edinb); 2018 Dec; 37():71-76. PubMed ID: 30326415
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Sutures versus staples for the management of surgical wounds: a meta-analysis of randomized controlled trials.
    Iavazzo C; Gkegkes ID; Vouloumanou EK; Mamais I; Peppas G; Falagas ME
    Am Surg; 2011 Sep; 77(9):1206-21. PubMed ID: 21944632
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intestinal surgery in small animals: historical foundations, current thinking, and future horizons.
    Ellison GW; Case JB; Regier PJ
    Vet Surg; 2019 Oct; 48(7):1171-1180. PubMed ID: 31286544
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessment of leakage pressure following enterotomy closure reinforced by tissue adhesive in a caprine cadaver model.
    Jones CT; Chen CY; Campbell BG; Fransson BA
    N Z Vet J; 2017 Sep; 65(5):248-251. PubMed ID: 28629261
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A new suture for hair transplantation: poliglecaprone 25.
    Bernstein RM; Rassman WR; Rashid N
    Dermatol Surg; 2001 Jan; 27(1):5-11. PubMed ID: 11231232
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of stainless steel fascial staples and polypropylene suture material for closure of the linea alba in dogs.
    Kirpensteijn J; Fingland RB; Boyer JE; Kennedy GA; Klemm RD; Debowes RM
    Vet Surg; 1993; 22(6):464-72. PubMed ID: 8116202
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intra-abdominal complications following intestinal anastomoses by suture and staple techniques in dogs.
    DePompeo CM; Bond L; George YE; Mezzles MJ; Brourman JD; Chandler JC; Murphy SM; Pike F; Mason DR
    J Am Vet Med Assoc; 2018 Aug; 253(4):437-443. PubMed ID: 30058972
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparing sutures versus staples for skin closure after orthopaedic surgery: systematic review and meta-analysis.
    Krishnan R; MacNeil SD; Malvankar-Mehta MS
    BMJ Open; 2016 Jan; 6(1):e009257. PubMed ID: 26792213
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The use of absorbable staples for skin closure after tibial plateau leveling osteotomy.
    Watson FC; McMullan W; Jordan CJ; Egan P; Tuan J; Solano MA; Fizpatrick N
    Vet Surg; 2019 Jan; 48(1):35-41. PubMed ID: 30378125
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of skin staplers in experimental gastrointestinal injuries.
    Dawson DL; Coil JA; Jadali M; Garrett G
    J Trauma; 1992 Feb; 32(2):204-9. PubMed ID: 1740803
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of adhesive polyurethane membrane and polypropylene sutures for closure of skin incisions in cats.
    Court MH; Bellenger CR
    Vet Surg; 1989; 18(3):211-5. PubMed ID: 2773283
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prevention of incisional hernias: how to close a midline incision.
    Israelsson LA; Millbourn D
    Surg Clin North Am; 2013 Oct; 93(5):1027-40. PubMed ID: 24035074
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of biofragmentable anastomosis ring and sutured anastomoses for subtotal colectomy in cats with idiopathic megacolon.
    Ryan S; Seim H; Macphail C; Bright R; Monnet E
    Vet Surg; 2006 Dec; 35(8):740-8. PubMed ID: 17187636
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.