These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

412 related articles for article (PubMed ID: 29642755)

  • 1. Successful treatment of ventricular arrhythmic storm with percutaneous coronary intervention and catheter ablation in a patient with left ventricular assist device.
    Sipahi NF; Mehdiani A; Saeed D; Boeken U; Makimoto H; Lichtenberg A; Dalyanoglu H
    Int J Artif Organs; 2018 Jun; 41(6):333-336. PubMed ID: 29642755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effectiveness of a percutaneous left ventricular assist device in preventing acute hemodynamic decompensation during catheter ablation of ventricular tachycardia in advanced heart failure patients: A retrospective single-center analysis.
    Neuzner J; Dietze T; Paliege R; Gradaus R
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2864-2868. PubMed ID: 31549434
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extracorporeal Membrane Oxygenation for Hemodynamic Support of Ventricular Tachycardia Ablation.
    Baratto F; Pappalardo F; Oloriz T; Bisceglia C; Vergara P; Silberbauer J; Albanese N; Cireddu M; D'Angelo G; Di Prima AL; Monaco F; Paglino G; Radinovic A; Regazzoli D; Silvetti S; Trevisi N; Zangrillo A; Della Bella P
    Circ Arrhythm Electrophysiol; 2016 Dec; 9(12):. PubMed ID: 27932426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A unique access for the ablation catheter to treat electrical storm in a patient with extracorporeal life support.
    Ücer E; Fredersdorf S; Jungbauer C; Debl K; Philipp A; Amann M; Holzamer A; Keyser A; Hilker M; Luchner A; Schmid C; Riegger G; Endemann D
    Europace; 2014 Feb; 16(2):299-302. PubMed ID: 23816515
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Novel minimally invasive surgical approach using an external ventricular assist device and extracorporeal membrane oxygenation in refractory cardiogenic shock.
    Takeda K; Garan AR; Topkara VK; Kirtane AJ; Karmpaliotis D; Kurlansky P; Yuzefpolskaya M; Colombo PC; Naka Y; Takayama H
    Eur J Cardiothorac Surg; 2017 Mar; 51(3):591-596. PubMed ID: 27818380
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Left stellate ganglion block for continuous ventricular arrhythmias during percutaneous left ventricular assist device support.
    Loyalka P; Hariharan R; Gholkar G; Gregoric ID; Tamerisa R; Nathan S; Kar B
    Tex Heart Inst J; 2011; 38(4):409-11. PubMed ID: 21841870
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effectiveness of Extracorporeal Life Support for Patients With Cardiogenic Shock Due To Intractable Arrhythmic Storm.
    Le Pennec-Prigent S; Flecher E; Auffret V; Leurent G; Daubert JC; Leclercq C; Mabo P; Verhoye JP; Martins RP
    Crit Care Med; 2017 Mar; 45(3):e281-e289. PubMed ID: 27755013
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Arrhythmic storm solved with ExtraCorporeal Membrane Oxygenation and consecutive percutaneous coronary intervention and ventricular tachycardia ablation.
    Sousa-Casasnovas I; Ávila-Alonso P; Juárez-Fernández M; Díez-Delhoyo F; Martínez-Sellés M; Fernández-Avilés F
    Med Intensiva (Engl Ed); 2018 Nov; 42(8):504-506. PubMed ID: 28662908
    [No Abstract]   [Full Text] [Related]  

  • 9. Percutaneous ventricular assist device placement during active cardiopulmonary resuscitation for severe refractory cardiogenic shock after acute myocardial infarction.
    Idelchik GM; Loyalka P; Kar B
    Tex Heart Inst J; 2007; 34(2):204-8. PubMed ID: 17622370
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characteristics of ventricular tachycardia ablation in patients with continuous flow left ventricular assist devices.
    Sacher F; Reichlin T; Zado ES; Field ME; Viles-Gonzalez JF; Peichl P; Ellenbogen KA; Maury P; Dukkipati SR; Picard F; Kautzner J; Barandon L; Koneru JN; Ritter P; Mahida S; Calderon J; Derval N; Denis A; Cochet H; Shepard RK; Corre J; Coffey JO; Garcia F; Hocini M; Tedrow U; Haissaguerre M; d'Avila A; Stevenson WG; Marchlinski FE; Jais P
    Circ Arrhythm Electrophysiol; 2015 Jun; 8(3):592-7. PubMed ID: 25870335
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Successful Use of Surgically Placed Impella 5.0 and Central Extracorporeal Membrane Oxygenation Circuit in a Patient with Postcardiotomy Shock.
    Abu Saleh WK; Mason P; Jabbari OA; Samir H; Bruckner BA
    Tex Heart Inst J; 2015 Dec; 42(6):569-71. PubMed ID: 26664314
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Successful Use of Percutaneous Left Ventricular Assist Device( Impella) and Veno Artery Extracorporeal Membrane Oxygenation( VA-ECMO) for Ischemic Cardiogenic Shock;Report of a Case].
    Tadakoshi M; Ohashi T; Kageyama S; Kojima A; Oshiro N; Kodani N; Kawasumi R; Yamaguchi T
    Kyobu Geka; 2019 Feb; 72(2):120-123. PubMed ID: 30772876
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous right ventricular assist device as support for cardiogenic shock due to right ventricular infarction.
    Prutkin JM; Strote JA; Stout KK
    J Invasive Cardiol; 2008 Jul; 20(7):E215-6. PubMed ID: 18599906
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outcomes of rescue cardiopulmonary support for periprocedural acute hemodynamic decompensation in patients undergoing catheter ablation of electrical storm.
    Enriquez A; Liang J; Gentile J; Schaller RD; Supple GE; Frankel DS; Garcia FC; Wald J; Birati EY; Rame JE; Bermudez C; Callans DJ; Marchlinski FE; Santangeli P
    Heart Rhythm; 2018 Jan; 15(1):75-80. PubMed ID: 28917560
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous Coronary Intervention Under Cover of Left Ventricular Assist Device (Impella 2.5).
    Iftikhar I; Khan HS; Kayani AM; Shahzad H
    J Coll Physicians Surg Pak; 2015 Oct; 25 Suppl 2():S78-80. PubMed ID: 26522210
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intra-Aortic Balloon Counterpulsation in Patients With Chronic Heart Failure and Cardiogenic Shock: Clinical Response and Predictors of Stabilization.
    Sintek MA; Gdowski M; Lindman BR; Nassif M; Lavine KJ; Novak E; Bach RG; Silvestry SC; Mann DL; Joseph SM
    J Card Fail; 2015 Nov; 21(11):868-76. PubMed ID: 26164215
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodynamic Support for Ventricular Tachycardia Ablation.
    Palaniswamy C; Miller MA; Reddy VY; Dukkipati SR
    Card Electrophysiol Clin; 2017 Mar; 9(1):141-152. PubMed ID: 28167082
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Catheter ablation of hemodynamically unstable ventricular tachycardia with mechanical circulatory support.
    Lü F; Eckman PM; Liao KK; Apostolidou I; John R; Chen T; Das GS; Francis GS; Lei H; Trohman RG; Benditt DG
    Int J Cardiol; 2013 Oct; 168(4):3859-65. PubMed ID: 23863501
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of a percutaneous left ventricular assist device for high-risk cardiac interventions and cardiogenic shock.
    Thomas JL; Al-Ameri H; Economides C; Shareghi S; Abad DG; Mayeda G; Burstein S; Shavelle DM
    J Invasive Cardiol; 2010 Aug; 22(8):360-4. PubMed ID: 20679671
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Right infarction response to coronary artery bypass and the Abiomed BVS 5000.
    Hisata Y; Hashizume K; Tanigawa K; Miura T; Odate T; Eishi K
    Asian Cardiovasc Thorac Ann; 2014 Mar; 22(3):329-31. PubMed ID: 24585910
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.