These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

496 related articles for article (PubMed ID: 29645282)

  • 1. Quality control methods for linear accelerator radiation and mechanical axes alignment.
    Létourneau D; Keller H; Becker N; Amin MN; Norrlinger B; Jaffray DA
    Med Phys; 2018 Jun; 45(6):2388-2398. PubMed ID: 29645282
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator.
    Du W; Gao S
    Med Phys; 2011 Aug; 38(8):4575-8. PubMed ID: 21928629
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An EPID-based method to determine mechanical deformations in a linear accelerator.
    Gourdeau D; Gingras L; Beaulieu F; Leclerc G; Archambault L
    Med Phys; 2018 Nov; 45(11):5054-5065. PubMed ID: 30242848
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the mechanical alignment of a linear accelerator with an electronic portal imaging device (EPID).
    Liu G; van Doorn T; Bezak E
    Australas Phys Eng Sci Med; 2000 Sep; 23(3):74-80. PubMed ID: 11210157
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator.
    Riis HL; Zimmermann SJ; Hjelm-Hansen M
    Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Alignment of multiradiation isocenters for megavoltage photon beam.
    Zhang Y; Ding K; Cowan G; Tryggestad E; Armour E; Wang KK
    J Appl Clin Med Phys; 2015 Nov; 16(6):314-324. PubMed ID: 26699586
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Quality control (QC) of CT on rail system (FOCAL Unit) with a micro-multi leaf collimator (mMLC) using new GafChromic film for stereotactic radiotherapy].
    Oita M; Takegawa Y; Yagi H; Ikushima H; Osaki K; Furutani S; Sasaki M; Tominaga M; Nishimoto Y; Nishitani H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 May; 62(5):711-3. PubMed ID: 16770852
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.
    Du W; Johnson JL; Jiang W; Kudchadker RJ
    J Appl Clin Med Phys; 2016 Jan; 17(1):167-178. PubMed ID: 26894350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room.
    Shirato H; Oita M; Fujita K; Shimizu S; Onimaru R; Uegaki S; Watanabe Y; Kato N; Miyasaka K
    Int J Radiat Oncol Biol Phys; 2004 Oct; 60(2):607-12. PubMed ID: 15380598
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointer.
    Tsai JS; Curran BH; Sternick ES; Engler MJ
    Int J Radiat Oncol Biol Phys; 1996 Jan; 34(1):189-95. PubMed ID: 12118550
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery.
    Yu VY; Tran A; Nguyen D; Cao M; Ruan D; Low DA; Sheng K
    Med Phys; 2015 Nov; 42(11):6457-67. PubMed ID: 26520735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved accuracy for noncoplanar radiotherapy: an EPID-based method for submillimeter alignment of linear accelerator table rotation with MV isocenter.
    Nyflot MJ; Cao N; Meyer J; Ford EC
    J Appl Clin Med Phys; 2014 Mar; 15(2):4682. PubMed ID: 24710457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comprehensive geometric quality assurance framework for preclinical microirradiators.
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2019 Apr; 46(4):1840-1851. PubMed ID: 30656713
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A procedure to determine the radiation isocenter size in a linear accelerator.
    González A; Castro I; Martínez JA
    Med Phys; 2004 Jun; 31(6):1489-93. PubMed ID: 15259652
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of an Elekta Versa HD linear accelerator for stereotactic radiosurgery with circular cone collimators.
    Zhang M; Fan Q; Lei Y; Thapa B; Padula G
    J Xray Sci Technol; 2020; 28(1):71-82. PubMed ID: 31904001
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy.
    Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y
    Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel method to determine linac mechanical isocenter position and size and examples of specific QA applications.
    Chojnowski JM; Sykes JR; Thwaites DI
    J Appl Clin Med Phys; 2021 Jul; 22(7):44-55. PubMed ID: 34056850
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automating linear accelerator quality assurance.
    Eckhause T; Al-Hallaq H; Ritter T; DeMarco J; Farrey K; Pawlicki T; Kim GY; Popple R; Sharma V; Perez M; Park S; Booth JT; Thorwarth R; Moran JM
    Med Phys; 2015 Oct; 42(10):6074-83. PubMed ID: 26429282
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Linac mechanic QA using a cylindrical phantom.
    Mamalui-Hunter M; Li H; Low DA
    Phys Med Biol; 2008 Sep; 53(18):5139-49. PubMed ID: 18723927
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries.
    Skworcow P; Mills JA; Haas OC; Burnham KJ
    Phys Med Biol; 2007 Dec; 52(23):7109-24. PubMed ID: 18029996
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.