These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

471 related articles for article (PubMed ID: 29656280)

  • 21. Re-endothelialisation after Synergy stent and Absorb bioresorbable vascular scaffold implantation in acute myocardial infarction: COVER-AMI study.
    Lhermusier T; Ohayon P; Boudou N; Bouisset F; Campelo-Parada F; Roncalli J; Elbaz M; Carrié D
    Trials; 2019 Apr; 20(1):210. PubMed ID: 30975219
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optical coherence tomography guidance for percutaneous coronary intervention with bioresorbable scaffolds.
    Caiazzo G; Longo G; Giavarini A; Kilic ID; Fabris E; Serdoz R; Mattesini A; Foin N; Secco GG; De Rosa S; Indolfi C; Di Mario C
    Int J Cardiol; 2016 Oct; 221():352-8. PubMed ID: 27404705
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Intraindividual Comparison of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Drug-Eluting Metallic Stents.
    Cassese S; Hoppmann P; Kufner S; Byrne RA; Wiebe J; Colleran R; Giacoppo D; Harada Y; Laugwitz KL; Schunkert H; Fusaro M; Kastrati A
    Circ Cardiovasc Interv; 2016 Aug; 9(8):. PubMed ID: 27512088
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry.
    La Manna A; Miccichè E; D'Agosta G; Tensol Rodrigues Pereira G; Attizzani GF; Capranzano P; Capodanno D; Tamburino C
    Int J Cardiol; 2018 Feb; 253():45-49. PubMed ID: 29137819
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A 12-month angiographic and optical coherence tomography follow-up after bioresorbable vascular scaffold implantation in patients with ST-segment elevation myocardial infarction.
    Kochman J; Tomaniak M; Kołtowski Ł; Jąkała J; Proniewska K; Legutko J; Roleder T; Pietrasik A; Rdzanek A; Kochman W; Brugaletta S; Kaluza GL
    Catheter Cardiovasc Interv; 2015 Oct; 86(4):E180-9. PubMed ID: 26015294
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes.
    Serruys PW; Onuma Y; Ormiston JA; de Bruyne B; Regar E; Dudek D; Thuesen L; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Dorange C; Veldhof S; Miquel-Hebert K; Rapoza R; García-García HM
    Circulation; 2010 Nov; 122(22):2301-12. PubMed ID: 21098436
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Is bioresorbable vascular scaffold acute recoil affected by baseline renal function and scaffold selection?
    Gunes HM; Yılmaz FK; Gokdeniz T; Demir GG; Guler E; Guler GB; Karaca O; Cakal B; İbişoğlu E; Boztosun B
    Int J Cardiol; 2016 Dec; 224():388-393. PubMed ID: 27681252
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The absorb bioresorbable vascular scaffold in coronary bifurcations: insights from bench testing.
    Džavík V; Colombo A
    JACC Cardiovasc Interv; 2014 Jan; 7(1):81-8. PubMed ID: 24332424
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The use of a scoring balloon for optimal lesion preparation prior to bioresorbable scaffold implantation: a comparison with conventional balloon predilatation.
    Miyazaki T; Latib A; Ruparelia N; Kawamoto H; Sato K; Figini F; Colombo A
    EuroIntervention; 2016 Apr; 11(14):e1580-8. PubMed ID: 27056118
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Coronary artery perforation after bioresorbable scaffold implantation treated with a new generation covered stent-OCT insights.
    Chen D; Gadeley R; Wang A; Jepson N
    BMC Cardiovasc Disord; 2022 Feb; 22(1):66. PubMed ID: 35196989
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Bioresorbable vascular scaffold use for coronary bifurcation lesions: A substudy from GHOST EU registry.
    Naganuma T; Colombo A; Lesiak M; Capodanno D; Gori T; Nef H; Caramanno G; Naber C; Di Mario C; Ruparelia N; Capranzano P; Wiebe J; Araszkiewicz A; Geraci S; Kawamoto H; Pyxaras S; Mattesini A; Münzel T; Tamburino C; Latib A
    Catheter Cardiovasc Interv; 2017 Jan; 89(1):47-56. PubMed ID: 27414021
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Bioresorbable vascular scaffold thrombosis in a consecutive cohort of 550 patients.
    Tröbs M; Achenbach S; Röther J; Klinghammer L; Schlundt C
    Catheter Cardiovasc Interv; 2016 Nov; 88(6):872-880. PubMed ID: 27142643
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial.
    Serruys PW; Chevalier B; Dudek D; Cequier A; Carrié D; Iniguez A; Dominici M; van der Schaaf RJ; Haude M; Wasungu L; Veldhof S; Peng L; Staehr P; Grundeken MJ; Ishibashi Y; Garcia-Garcia HM; Onuma Y
    Lancet; 2015 Jan; 385(9962):43-54. PubMed ID: 25230593
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clinical utility of optical coherence tomography (OCT) in the optimisation of Absorb bioresorbable vascular scaffold deployment during percutaneous coronary intervention.
    Allahwala UK; Cockburn JA; Shaw E; Figtree GA; Hansen PS; Bhindi R
    EuroIntervention; 2015 Feb; 10(10):1154-9. PubMed ID: 24647105
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Bioresorbable everolimus-eluting vascular scaffold in patients with ST-segment elevation myocardial infarction: Optical coherence tomography evaluation and clinical outcomes.
    Kochman J; Tomaniak M; Pietrasik A; Kołtowski Ł; Rdzanek A; Huczek Z; Mazurek T; Jąkała J; Ząbek A; Legutko J; Kochman W; Filipiak KJ
    Cardiol J; 2015; 22(3):315-22. PubMed ID: 25428734
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The use of bioresorbable vascular scaffold Absorb BVS® in patients with stable coronary artery disease: one-year results with special focus on the hybrid bioresorbable vascular scaffolds and drug eluting stents treatment.
    Gil RJ; Bil J; Pawłowski T; Yuldashev N; Kołakowski L; Jańczak J; Jabłoński W; Paliński P
    Kardiol Pol; 2016; 74(7):627-33. PubMed ID: 26779846
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Routine use of optical coherence tomography in bioresorbable vascular scaffold implantation: insights on technique optimization and long-term outcomes.
    Abdelaziz HK; Abuomara HZ; Ali MH; Eichhofer J; Patel B; Saad M
    Coron Artery Dis; 2019 Jun; 30(4):263-269. PubMed ID: 30883433
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of in vivo acute stent recoil between the bioresorbable everolimus-eluting coronary scaffolds (revision 1.0 and 1.1) and the metallic everolimus-eluting stent.
    Onuma Y; Serruys PW; Gomez J; de Bruyne B; Dudek D; Thuesen L; Smits P; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Garcia-Garcia H; Ormiston JA;
    Catheter Cardiovasc Interv; 2011 Jul; 78(1):3-12. PubMed ID: 21413120
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Bioresorbable vascular scaffolds in coronary chronic total occlusions revascularization: safety assessment related to struts coverage and apposition in 6-month OCT follow-up.
    Abellas-Sequeiros RA; Ocaranza-Sanchez R; Trillo-Nouche R; Gonzalez-Juanatey C; Gonzalez-Juanatey JR
    Heart Vessels; 2017 Sep; 32(9):1077-1084. PubMed ID: 28432385
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hybrid Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffolds in Combination With Drug-Eluting Stents or Drug-Coated Balloons for Complex Coronary Lesions.
    Tanaka A; Jabbour RJ; Mitomo S; Latib A; Colombo A
    JACC Cardiovasc Interv; 2017 Mar; 10(6):539-547. PubMed ID: 28335892
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 24.