BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 29658864)

  • 1. Right Ventricular Perforation by a Defibrillator Lead Migrating to the Left Breast.
    Tasic J; Zbacnik R; Zupan I; Ksela J
    Heart Surg Forum; 2018 Mar; 21(2):E087-E089. PubMed ID: 29658864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multimodality imaging of right ventricular perforation secondary to pacing lead migration.
    Victor K; Rajani R; Carr-White GS; Aldo Rinaldi C
    Eur Heart J Cardiovasc Imaging; 2013 Apr; 14(4):330. PubMed ID: 23070066
    [No Abstract]   [Full Text] [Related]  

  • 3. Subacute perforation of the St. Jude Riata implantable cardioverter-defibrillator lead: a report of two pediatric cases.
    Morrison TB; Ackerman MJ; Rea RF
    Pediatr Cardiol; 2009 Aug; 30(6):834-6. PubMed ID: 19365657
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Right ventricular perforation with an ICD defibrillation lead managed by surgical revision and epicardial leads--case reports.
    Krivan L; Kozák M; Vlasínová J; Sepsi M
    Pacing Clin Electrophysiol; 2008 Jan; 31(1):3-6. PubMed ID: 18181900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Right ventricular perforation due to migration of a ventricular lead.
    Doguet F; Savouré A; Baste JM; Bessou JP
    J Card Surg; 2010 May; 25(3):303. PubMed ID: 20149012
    [No Abstract]   [Full Text] [Related]  

  • 6. Management of traumatic implantable cardioverter defibrillator lead perforation of the right ventricle after car accident: a case report.
    Sassone B; Gabrieli L; Boggian G; Pilato E
    Europace; 2009 Jul; 11(7):961-2. PubMed ID: 19451098
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incidence, management, and prevention of right ventricular perforation by pacemaker and implantable cardioverter defibrillator leads.
    Migliore F; Zorzi A; Bertaglia E; Leoni L; Siciliano M; De Lazzari M; Ignatiuk B; Veronese M; Verlato R; Tarantini G; Iliceto S; Corrado D
    Pacing Clin Electrophysiol; 2014 Dec; 37(12):1602-9. PubMed ID: 25131984
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous lead extraction and repositioning: An effective and safe therapeutic strategy for early ventricular lead perforation with dislocation both inside and outside the pericardial sac following a cardiac device implantation.
    Archontakis S; Sideris K; Aggeli K; Gatzoulis K; Demosthenous M; Tolios P; Lozos V; Koumallos N; Limperiadis D; Tousoulis D; Kallikazaros I; Sideris S
    J Cardiovasc Electrophysiol; 2019 Mar; 30(3):299-307. PubMed ID: 30516299
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Asymptomatic right ventricular perforation by an implantable cardioverter defibrillator lead detected by home monitoring system.
    Migliore F; Leoni L; Torregrossa G; Guglielmi C; Tarantini G; Buja G; Iliceto S; Corrado D
    J Electrocardiol; 2010; 43(6):673-5. PubMed ID: 20888001
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Delayed right ventricular perforation in patient with implantable cardioverter - defibrillator.
    Fagundes AA; Magalhães LP; Pinheiro J; Flausino L; Souza LR
    Arq Bras Cardiol; 2010 Dec; 95(6):e148-50. PubMed ID: 21271186
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidental detection of single coil right ventricular lead perforation during aortic valve surgery.
    Herrmann FEM; Juchem G; Hagl C; Schramm R; Sadoni S
    J Cardiovasc Electrophysiol; 2019 Aug; 30(8):1371-1372. PubMed ID: 31115942
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Management of subacute and delayed right ventricular perforation with a pacing or an implantable cardioverter-defibrillator lead.
    Laborderie J; Barandon L; Ploux S; Deplagne A; Mokrani B; Reuter S; Le Gal F; Jais P; Haissaguerre M; Clementy J; Bordachar P
    Am J Cardiol; 2008 Nov; 102(10):1352-5. PubMed ID: 18993154
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Timing of delayed perforation with the St. Jude Riata lead: a single-center experience and a review of the literature.
    Danik SB; Mansour M; Heist EK; Ellinor P; Milan D; Singh J; Das S; Reddy V; D'Avila A; Ruskin JN; Mela T
    Heart Rhythm; 2008 Dec; 5(12):1667-72. PubMed ID: 19084802
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Delayed right-ventricular perforation of a pacemaker lead.
    Hörer J; Will A; Schreiber C
    Pediatr Cardiol; 2011 Jun; 32(5):708-9. PubMed ID: 21472375
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Delayed right-ventricular perforation by pacemaker lead; a rare complication in a 12-year-old girl.
    Aykan HH; Akın A; Ertuğrul İ; Karagöz T
    Turk Kardiyol Dern Ars; 2015 Mar; 43(2):185-7. PubMed ID: 25782125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac perforation caused by cement after percutaneous balloon kyphoplasty.
    Ishikawa K; Hayashi H; Mori H
    Asian Cardiovasc Thorac Ann; 2017 Mar; 25(3):204-206. PubMed ID: 26542782
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Delayed defibrillator lead perforation: an increasing phenomenon.
    Satpathy R; Hee T; Esterbrooks D; Mohiuddin S
    Pacing Clin Electrophysiol; 2008 Jan; 31(1):10-2. PubMed ID: 18181902
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Subacute right ventricular pacemaker lead perforation: evaluation by echocardiography and cardiac CT.
    Boxma RPJ; Kolff-Kamphuis MGM; Gevers RMM; Boulaksil M
    J Echocardiogr; 2017 Dec; 15(4):188-190. PubMed ID: 28466446
    [No Abstract]   [Full Text] [Related]  

  • 19. Transvenous revision of leads with cardiac perforation following device implantation-Safety, outcome, and complications.
    Döring M; Müssigbrodt A; Ebert M; Bode K; Lucas J; Dagres N; Hindricks G; Richter S
    Pacing Clin Electrophysiol; 2020 Nov; 43(11):1325-1332. PubMed ID: 32909622
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Incidence and predictors of clinically relevant cardiac perforation associated with systematic implantation of active-fixation pacing and defibrillation leads: a single-centre experience with over 3800 implanted leads.
    Cano Ó; Andrés A; Alonso P; Osca J; Sancho-Tello MJ; Olagüe J; Martínez-Dolz L
    Europace; 2017 Jan; 19(1):96-102. PubMed ID: 26847075
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.