These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

376 related articles for article (PubMed ID: 29666072)

  • 1. Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk.
    Chivukula VK; Beckman JA; Prisco AR; Dardas T; Lin S; Smith JW; Mokadam NA; Aliseda A; Mahr C
    Circ Heart Fail; 2018 Apr; 11(4):e004325. PubMed ID: 29666072
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Left Ventricular Assist Device Inflow Cannula Insertion Depth Influences Thrombosis Risk.
    Chivukula VK; Beckman JA; Li S; Masri SC; Levy WC; Lin S; Cheng RK; Farris SD; Wood G; Dardas TF; Kirkpatrick JN; Koomalsingh K; Zimpfer D; Mackensen GB; Chassagne F; Mahr C; Aliseda A
    ASAIO J; 2020 Jul; 66(7):766-773. PubMed ID: 31453832
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of left ventricular assist device inflow cannula position on thrombosis risk.
    Ghodrati M; Maurer A; Schlöglhofer T; Khienwad T; Zimpfer D; Beitzke D; Zonta F; Moscato F; Schima H; Aigner P
    Artif Organs; 2020 Sep; 44(9):939-946. PubMed ID: 32302423
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD.
    May-Newman K; Montes R; Campos J; Marquez-Maya N; Vu V; Zebrowski E; Motomura T; Benkowski R
    Artif Organs; 2019 Sep; 43(9):834-848. PubMed ID: 31038753
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Computational Investigation of the Effects of Temporal Synchronization of Left Ventricular Assist Device Speed Modulation with the Cardiac Cycle on Intraventricular Hemodynamics.
    Straccia A; Chassagne F; Barbour MC; Beckman J; Li S; Mahr C; Aliseda A
    Ann Biomed Eng; 2024 Jun; 52(6):1763-1778. PubMed ID: 38517620
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Understanding the influence of left ventricular assist device inflow cannula alignment and the risk of intraventricular thrombosis.
    Neidlin M; Liao S; Li Z; Simpson B; Kaye DM; Steinseifer U; Gregory S
    Biomed Eng Online; 2021 May; 20(1):47. PubMed ID: 33975591
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Numerical prediction of thrombus risk in an anatomically dilated left ventricle: the effect of inflow cannula designs.
    Liao S; Simpson B; Neidlin M; Kaufmann TA; Li Z; Woodruff MA; Gregory SD
    Biomed Eng Online; 2016 Dec; 15(Suppl 2):136. PubMed ID: 28155674
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.
    Hanke JS; Krabatsch T; Rojas SV; Deniz E; Ismail I; Martens A; Shrestha M; Haverich A; Netuka I; Schmitto JD
    Artif Organs; 2017 Mar; 41(3):272-275. PubMed ID: 27087560
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Small Left Ventricular Size Is an Independent Risk Factor for Ventricular Assist Device Thrombosis.
    Chivukula VK; Beckman JA; Prisco AR; Lin S; Dardas TF; Cheng RK; Farris SD; Smith JW; Mokadam NA; Mahr C; Aliseda A
    ASAIO J; 2019 Feb; 65(2):152-159. PubMed ID: 29677037
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Effect of Inflow Cannula Angle on the Intraventricular Flow Field of the Left Ventricular Assist Device-Assisted Heart: An In Vitro Flow Visualization Study.
    May-Newman K; Marquez-Maya N; Montes R; Salim S
    ASAIO J; 2019 Feb; 65(2):139-147. PubMed ID: 29613888
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Atrial fibrillation increases thrombogenicity of LVAD therapy.
    Keshav Chivukula V; Beckman J; Li S; Akoum N; Aliseda A; Mahr C
    Int J Artif Organs; 2024 May; 47(5):329-337. PubMed ID: 38742880
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model.
    Khamooshi M; Azimi M; Gregory SD
    Comput Methods Programs Biomed; 2023 Oct; 240():107730. PubMed ID: 37531687
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The axial continuous-flow blood pump: Bench evaluation of changes in flow associated with changes of inflow cannula angle.
    Karimov JH; Zhen-Yu Tong M; Byram N; Sunagawa G; Dessoffy R; Moazami N; Starling RC; Fukamachi K
    J Heart Lung Transplant; 2017 Jan; 36(1):106-112. PubMed ID: 28029574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proposing a novel technique to exclude the left ventricle with an assist device: insights from 4-dimensional flow magnetic resonance imaging.
    Klotz S; Meyer-Saraei R; Frydrychowicz A; Scharfschwerdt M; Putman LM; Halder S; Sievers HH
    Eur J Cardiothorac Surg; 2016 Sep; 50(3):439-45. PubMed ID: 27107046
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Virtual Fitting and Hemodynamic Simulation of the EVAHEART 2 Left Ventricular Assist Device and Double-Cuff Tipless Inflow Cannula.
    Sonntag SJ; Lipinski E; Neidlin M; Hugenroth K; Benkowski R; Motomura T; Kaufmann TAS
    ASAIO J; 2019; 65(7):698-706. PubMed ID: 30134259
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Numerical study of the effect of LVAD inflow cannula positioning on thrombosis risk.
    He G; Han L; Zhang J; Shah A; Kaczorowski DJ; Griffith BP; Wu Z
    Comput Methods Biomech Biomed Engin; 2022 Jun; 25(8):852-860. PubMed ID: 34592878
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Left Ventricular Flow Dynamics with the HeartMate3 Left Ventricular Assist Device: Effect of Inflow Cannula Position and Speed Modulation.
    Ortiz S; Vu V; Montes R; May-Newman K
    ASAIO J; 2021 Dec; 67(12):1301-1311. PubMed ID: 34261878
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Left Ventricular Assist Device Flow Pattern Analysis Using a Novel Model Incorporating Left Ventricular Pulsatility.
    Grinstein J; Torii R; Bourantas CV; Garcia-Garcia HM
    ASAIO J; 2021 Jul; 67(7):724-732. PubMed ID: 33528162
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk.
    Osorio AF; Osorio R; Ceballos A; Tran R; Clark W; Divo EA; Argueta-Morales IR; Kassab AJ; DeCampli WM
    Comput Methods Biomech Biomed Engin; 2013; 16(6):622-38. PubMed ID: 22185643
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational fluid dynamic analysis to prevent aortic root and valve clots during left ventricular assist device support.
    Poullis M
    J Extra Corpor Technol; 2012 Dec; 44(4):210-5. PubMed ID: 23441562
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.