These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 29675905)

  • 1. Transient left anterior and septal fascicular blocks after self-expandable percutaneous transcatheter aortic valve implantation.
    Pérez-Riera AR; Barbosa-Barros R; Cabral de Oliveira MF; Daminello-Raimundo R; de Abreu LC; Nikus K
    Ann Noninvasive Electrocardiol; 2019 Jul; 24(4):e12553. PubMed ID: 29675905
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Transcatheter aortic valve implantation and conduction disturbances].
    Ait Said M; Coquard C; Horvilleur J; Manenti V; Fiorina L; Lacotte J; Salerno F
    Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):443-449. PubMed ID: 31668339
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-degree atrioventricular block in patients with preexisting bundle branch block or bundle branch block occurring during transcatheter aortic valve implantation.
    Egger F; Nürnberg M; Rohla M; Weiss TW; Unger G; Smetana P; Geppert A; Gruber SC; Bambazek A; Falkensammer J; Waldenberger FR; Huber K; Freynhofer MK
    Heart Rhythm; 2014 Dec; 11(12):2176-82. PubMed ID: 25034184
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Risk factors for atrioventricular block after transcatheter aortic valve implantation: a single-centre analysis including assessment of aortic calcifications and follow-up.
    Pollari F; Großmann I; Vogt F; Kalisnik JM; Cuomo M; Schwab J; Fischlein T; Pfeiffer S
    Europace; 2019 May; 21(5):787-795. PubMed ID: 30629159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis.
    Mogilansky C; Balan R; Deutsch C; Czesla M; Massoudy P
    Interact Cardiovasc Thorac Surg; 2019 Apr; 28(4):581-586. PubMed ID: 30412244
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Conduction disturbance after isolated surgical aortic valve replacement in degenerative aortic stenosis.
    Hwang YM; Kim J; Lee JH; Kim M; Hwang J; Kim JB; Jung SH; Choo SJ; Nam GB; Choi KJ; Chung CH; Lee JW; Kim YH
    J Thorac Cardiovasc Surg; 2017 Nov; 154(5):1556-1565.e1. PubMed ID: 28712585
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.
    Krackhardt F; Kherad B; Krisper M; Pieske B; Laule M; Tschöpe C
    Cardiol J; 2017; 24(3):250-258. PubMed ID: 28248410
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of native aortic valve calcium and transcatheter valve oversize on the need for pacemaker implantation after transcatheter aortic valve insertion.
    Al-Azzam F; Greason KL; Krittanawong C; Williamson EE; McLeod CJ; King KS; Mathew V
    J Thorac Cardiovasc Surg; 2017 May; 153(5):1056-1062.e1. PubMed ID: 28073567
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Atrioventricular and intraventricular block after transcatheter aortic valve implantation.
    Lee JJ; Goldschlager N; Mahadevan VS
    J Interv Card Electrophysiol; 2018 Aug; 52(3):315-322. PubMed ID: 29936634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Frequency of conduction disturbances after Edwards SAPIEN percutaneous valve implantation.
    Laynez A; Ben-Dor I; Barbash IM; Hauville C; Sardi G; Maluenda G; Xue Z; Satler LF; Pichard AD; Lindsay J; Waksman R
    Am J Cardiol; 2012 Oct; 110(8):1164-8. PubMed ID: 22770935
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation.
    López-Aguilera J; Segura Saint-Gerons JM; Mazuelos Bellido F; Suárez de Lezo J; Ojeda Pineda S; Pan Álvarez-Ossorio M; Romero Moreno MÁ; Pavlovic D; Espejo Pérez S; Suárez de Lezo J
    Rev Esp Cardiol (Engl Ed); 2016 Jan; 69(1):28-36. PubMed ID: 26215663
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve versus the Edwards valve.
    Franzoni I; Latib A; Maisano F; Costopoulos C; Testa L; Figini F; Giannini F; Basavarajaiah S; Mussardo M; Slavich M; Taramasso M; Cioni M; Longoni M; Ferrarello S; Radinovic A; Sala S; Ajello S; Sticchi A; Giglio M; Agricola E; Chieffo A; Montorfano M; Alfieri O; Colombo A
    Am J Cardiol; 2013 Aug; 112(4):554-9. PubMed ID: 23726173
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Alternating Bundle Branch Block With Paroxysmal Atrioventricular Block 22 Months After Valve-in-Valve Transcatheter Aortic Valve Replacement.
    Ishiguchi H; Okamura T; Kobayashi S; Yano M
    Circ J; 2021 Dec; 86(1):170. PubMed ID: 34483227
    [No Abstract]   [Full Text] [Related]  

  • 16. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prognosis assessment of persistent left bundle branch block after TAVI by an electrophysiological and remote monitoring risk-adapted algorithm: rationale and design of the multicentre LBBB-TAVI Study.
    Massoullié G; Bordachar P; Irles D; Caussin C; Da Costa A; Defaye P; Jean F; Mechulan A; Mondoly P; Souteyrand G; Pereira B; Ploux S; Eschalier R
    BMJ Open; 2016 Oct; 6(10):e010485. PubMed ID: 27797979
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aortic annulus to left coronary distance as a predictor for persistent left bundle branch block after TAVI.
    Hein-Rothweiler R; Jochheim D; Rizas K; Egger A; Theiss H; Bauer A; Massberg S; Mehilli J
    Catheter Cardiovasc Interv; 2017 Mar; 89(4):E162-E168. PubMed ID: 27038099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Predictors of permanent pacemaker implantation after transfemoral aortic valve implantation with the Lotus valve.
    Keßler M; Gonska B; Seeger J; Rottbauer W; Wöhrle J
    Am Heart J; 2017 Oct; 192():57-63. PubMed ID: 28938964
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.