These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

281 related articles for article (PubMed ID: 29678635)

  • 21. [High performance of an implantable Holter monitor in the detection of concealed paroxysmal atrial fibrillation in patients with cryptogenic stroke and a suspected embolic mechanism].
    Rojo-Martinez E; Sandín-Fuentes M; Calleja-Sanz AI; Cortijo-García E; García-Bermejo P; Ruiz-Piñero M; Rubio-Sanz J; Arenillas-Lara JF
    Rev Neurol; 2013 Sep; 57(6):251-7. PubMed ID: 24008935
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Predictors of finding occult atrial fibrillation after cryptogenic stroke.
    Favilla CG; Ingala E; Jara J; Fessler E; Cucchiara B; Messé SR; Mullen MT; Prasad A; Siegler J; Hutchinson MD; Kasner SE
    Stroke; 2015 May; 46(5):1210-5. PubMed ID: 25851771
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cryptogenic Stroke and underlying Atrial Fibrillation (CRYSTAL AF): design and rationale.
    Sinha AM; Diener HC; Morillo CA; Sanna T; Bernstein RA; Di Lazzaro V; Passman R; Beckers F; Brachmann J
    Am Heart J; 2010 Jul; 160(1):36-41.e1. PubMed ID: 20598970
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Paroxysmal atrial fibrillation occurs often in cryptogenic ischaemic stroke. Final results from the SURPRISE study.
    Christensen LM; Krieger DW; Højberg S; Pedersen OD; Karlsen FM; Jacobsen MD; Worck R; Nielsen H; Aegidius K; Jeppesen LL; Rosenbaum S; Marstrand J; Christensen H
    Eur J Neurol; 2014 Jun; 21(6):884-9. PubMed ID: 24628954
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Real-world performance of an enhanced atrial fibrillation detection algorithm in an insertable cardiac monitor.
    Mittal S; Rogers J; Sarkar S; Koehler J; Warman EN; Tomson TT; Passman RS
    Heart Rhythm; 2016 Aug; 13(8):1624-30. PubMed ID: 27165694
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke.
    Cotter PE; Martin PJ; Ring L; Warburton EA; Belham M; Pugh PJ
    Neurology; 2013 Apr; 80(17):1546-50. PubMed ID: 23535493
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effectiveness, utilisation and cost associated with implantable loop recorders versus external monitors after ischaemic or cryptogenic stroke.
    Dhruva SS; Murillo J; Ameli O; Chaisson CE; Redberg RF; Cohen K
    Open Heart; 2024 May; 11(1):. PubMed ID: 38719499
    [TBL] [Abstract][Full Text] [Related]  

  • 28. P-wave terminal force in lead V
    Ikenouchi H; Koge J; Tanaka T; Yamaguchi E; Egashira S; Doijiri R; Yamazaki H; Sonoda K; Iwata T; Todo K; Ueno Y; Yamagami H; Ihara M; Toyoda K; Koga M
    J Thromb Thrombolysis; 2023 Jul; 56(1):103-110. PubMed ID: 37130975
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Atrial fibrillation post central retinal artery occlusion: Role of implantable loop recorders.
    Watson RA; Wellings J; Hingorani R; Zhan T; Frisch DR; Ho RT; Pavri BB; Sergott RC; Greenspon AJ
    Pacing Clin Electrophysiol; 2020 Sep; 43(9):992-999. PubMed ID: 32567072
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Immediate implantable loop recorder implantation for detecting atrial fibrillation in cryptogenic stroke.
    Dulai R; Hunt J; Veasey RA; Biyanwila C; O'Neill B; Patel N
    J Stroke Cerebrovasc Dis; 2023 Mar; 32(3):106988. PubMed ID: 36645969
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessing arrhythmia burden after catheter ablation of atrial fibrillation using an implantable loop recorder: the ABACUS study.
    Kapa S; Epstein AE; Callans DJ; Garcia FC; Lin D; Bala R; Riley MP; Hutchinson MD; Gerstenfeld EP; Tzou W; Marchlinski FE; Frankel DS; Cooper JM; Supple G; Deo R; Verdino RJ; Patel VV; Dixit S
    J Cardiovasc Electrophysiol; 2013 Aug; 24(8):875-81. PubMed ID: 23577826
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Implantable Loop Recorders-Syncope, Cryptogenic Stroke, Atrial Fibrillation.
    Mittal S
    Card Electrophysiol Clin; 2021 Sep; 13(3):439-447. PubMed ID: 34330371
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Meta-Analysis of Randomized Clinical Trials Comparing the Impact of Implantable Loop Recorder Versus Usual Care After Ischemic Stroke for Detection of Atrial Fibrillation and Stroke Risk.
    Ko D; Dai Q; Flynn DB; Bosch NA; Helm RH; Monahan KM; Andersson C; Anderson CD; Walkey AJ
    Am J Cardiol; 2022 Jan; 162():100-104. PubMed ID: 34756594
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Insertable cardiac monitors for detection of atrial fibrillation after cryptogenic stroke: a meta-analysis.
    Lu Y; Diao SS; Huang SJ; Zhao JJ; Ye MF; Yao FR; Kong Y; Xu Z
    Neurol Sci; 2021 Oct; 42(10):4139-4148. PubMed ID: 33528671
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ultra-early continuous cardiac monitoring improves atrial fibrillation detection and prognosis of patients with cryptogenic stroke.
    Cuadrado-Godia E; Benito B; Ois A; Vallès E; Rodríguez-Campello A; Giralt-Steinhauer E; Cabrera S; Alcalde O; Jiménez-López J; Jiménez-Conde J; Martí-Almor J; Roquer J
    Eur J Neurol; 2020 Feb; 27(2):244-250. PubMed ID: 31424609
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter.
    Mittal S; Pokushalov E; Romanov A; Ferrara M; Arshad A; Musat D; Preminger M; Sichrovsky T; Steinberg JS
    Heart Rhythm; 2013 Nov; 10(11):1598-604. PubMed ID: 23911429
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Long-term detection of atrial fibrillation with insertable cardiac monitors in a real-world cryptogenic stroke population.
    Ziegler PD; Rogers JD; Ferreira SW; Nichols AJ; Richards M; Koehler JL; Sarkar S
    Int J Cardiol; 2017 Oct; 244():175-179. PubMed ID: 28624331
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Unexpected low prevalence of atrial fibrillation in cryptogenic ischemic stroke: a prospective study.
    Dion F; Saudeau D; Bonnaud I; Friocourt P; Bonneau A; Poret P; Giraudeau B; Régina S; Fauchier L; Babuty D
    J Interv Card Electrophysiol; 2010 Aug; 28(2):101-7. PubMed ID: 20454840
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Implantable loop recorders in patients with atrial fibrillation.
    Sharma AN; McIntyre WF; Nguyen ST; Baranchuk A
    Expert Rev Cardiovasc Ther; 2022 Dec; 20(12):919-928. PubMed ID: 36444859
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Silent ischaemic brain lesions related to atrial high rate episodes in patients with cardiac implantable electronic devices.
    Benezet-Mazuecos J; Rubio JM; Cortés M; Iglesias JA; Calle S; de la Vieja JJ; Quiñones MA; Sanchez-Borque P; de la Cruz E; Espejo A; Farré J
    Europace; 2015 Mar; 17(3):364-9. PubMed ID: 25336664
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.