These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
303 related articles for article (PubMed ID: 29688098)
21. Clinical implications of Mycobacterium chimaera detection in thermoregulatory devices used for extracorporeal membrane oxygenation (ECMO), Germany, 2015 to 2016. Trudzinski FC; Schlotthauer U; Kamp A; Hennemann K; Muellenbach RM; Reischl U; Gärtner B; Wilkens H; Bals R; Herrmann M; Lepper PM; Becker SL Euro Surveill; 2016 Nov; 21(46):. PubMed ID: 27918254 [TBL] [Abstract][Full Text] [Related]
22. Mycobacterium chimaera in Heater-Cooler Units in Denmark Related to Isolates from the United States and United Kingdom. Svensson E; Jensen ET; Rasmussen EM; Folkvardsen DB; Norman A; Lillebaek T Emerg Infect Dis; 2017 Mar; 23(3):507-509. PubMed ID: 28035898 [TBL] [Abstract][Full Text] [Related]
23. Responding to Mycobacterium chimaera heater-cooler unit contamination: international and national intersectoral collaboration coordinated in the state of Queensland, Australia. Robertson J; McLellan S; Donnan E; Sketcher-Baker K; Wakefield J; Coulter C J Hosp Infect; 2018 Nov; 100(3):e77-e84. PubMed ID: 30036634 [TBL] [Abstract][Full Text] [Related]
24. Contamination during production of heater-cooler units by Mycobacterium chimaera potential cause for invasive cardiovascular infections: results of an outbreak investigation in Germany, April 2015 to February 2016. Haller S; Höller C; Jacobshagen A; Hamouda O; Abu Sin M; Monnet DL; Plachouras D; Eckmanns T Euro Surveill; 2016 Apr; 21(17):. PubMed ID: 27168588 [TBL] [Abstract][Full Text] [Related]
25. Healthcare-Associated Mycobacterium chimaera Infection Subsequent to Heater-Cooler Device Exposure During Cardiac Surgery. Ninh A; Weiner M; Goldberg A J Cardiothorac Vasc Anesth; 2017 Oct; 31(5):1831-1835. PubMed ID: 28838729 [TBL] [Abstract][Full Text] [Related]
26. Insidious Risk of Severe Mycobacterium chimaera Infection in Cardiac Surgery Patients. Chand M; Lamagni T; Kranzer K; Hedge J; Moore G; Parks S; Collins S; Del Ojo Elias C; Ahmed N; Brown T; Smith EG; Hoffman P; Kirwan P; Mason B; Smith-Palmer A; Veal P; Lalor MK; Bennett A; Walker J; Yeap A; Isidro Carrion Martin A; Dolan G; Bhatt S; Skingsley A; Charlett A; Pearce D; Russell K; Kendall S; Klein AA; Robins S; Schelenz S; Newsholme W; Thomas S; Collyns T; Davies E; McMenamin J; Doherty L; Peto TE; Crook D; Zambon M; Phin N Clin Infect Dis; 2017 Feb; 64(3):335-342. PubMed ID: 27927870 [TBL] [Abstract][Full Text] [Related]
27. Real-time PCR, the best approaches for rapid testing for Ditommaso S; Giacomuzzi M; Memoli G; Zotti CM Perfusion; 2021 Sep; 36(6):626-629. PubMed ID: 33054627 [TBL] [Abstract][Full Text] [Related]
28. Elimination of Mycobacterium chimaera in a heater cooler device used during on-pump cardiothoracic surgery. Nielsen C; Winther CL; Thomsen PK; Andreasen JJ Perfusion; 2017 Sep; 32(6):507-510. PubMed ID: 28820031 [TBL] [Abstract][Full Text] [Related]
29. Vermamoeba vermiformis resides in water-based heater-cooler units and can enhance Mycobacterium chimaera survival after chlorine exposure. Sarink MJ; van Cappellen WA; Tielens AGM; van Dijk A; Bogers AJJC; de Steenwinkel JEM; Vos MC; Severin JA; van Hellemond JJ J Hosp Infect; 2023 Feb; 132():73-77. PubMed ID: 36572347 [TBL] [Abstract][Full Text] [Related]
30. Notes from the Field: Mycobacterium chimaera Contamination of Heater-Cooler Devices Used in Cardiac Surgery - United States. Perkins KM; Lawsin A; Hasan NA; Strong M; Halpin AL; Rodger RR; Moulton-Meissner H; Crist MB; Schwartz S; Marders J; Daley CL; Salfinger M; Perz JF MMWR Morb Mortal Wkly Rep; 2016 Oct; 65(40):1117-1118. PubMed ID: 27740609 [TBL] [Abstract][Full Text] [Related]
31. Mycobacterium chimaera in heater-cooler units: new technical approach for treatment, cleaning and disinfection protocol. Colangelo N; Giambuzzi I; Moro M; Pasqualini N; Aina A; De Simone F; Blasio A; Alfieri O; Castiglioni A; De Bonis M Perfusion; 2019 May; 34(4):272-276. PubMed ID: 30541392 [TBL] [Abstract][Full Text] [Related]
32. Decontamination of an Extracorporeal Membrane Oxygenator Contaminated With Mycobacterium chimaera. Garvey MI; Phillips N; Bradley CW; Holden E Infect Control Hosp Epidemiol; 2017 Oct; 38(10):1244-1246. PubMed ID: 28803570 [TBL] [Abstract][Full Text] [Related]
34. A solution for global hygienic challenges regarding the application of heater-cooler systems in cardiac surgery. Foltan M; Nikisch A; Dembianny J; Miano AL; Heinze J; Klar D; Göbölös L; Lehle K; Schmid C Perfusion; 2023 Jan; 38(1):28-36. PubMed ID: 34256647 [TBL] [Abstract][Full Text] [Related]
35. Clinical characteristics and outcome of Mycobacterium chimaera infections after cardiac surgery: systematic review and meta-analysis of 180 heater-cooler unit-associated cases. Wetzstein N; Kohl TA; Diricks M; Mas-Peiro S; Holubec T; Kessel J; Graf C; Koch B; Herrmann E; Vehreschild MJGT; Hogardt M; Niemann S; Stephan C; Wichelhaus TA Clin Microbiol Infect; 2023 Aug; 29(8):1008-1014. PubMed ID: 36918144 [TBL] [Abstract][Full Text] [Related]
36. Longitudinal increase in the detection rate of Mycobacterium chimaera in heater-cooler device-derived water samples. Schreiber PW; Zihlmann R; Schärer V; Hasse B; Imkamp F; Schulthess B; Sander P; Zingg W J Hosp Infect; 2023 Jan; 131():190-193. PubMed ID: 36410531 [TBL] [Abstract][Full Text] [Related]
37. Disinfection and cleaning of heater-cooler units: suspension- and biofilm-killing. Falkinham JO J Hosp Infect; 2020 May; ():. PubMed ID: 32422308 [TBL] [Abstract][Full Text] [Related]