These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

260 related articles for article (PubMed ID: 29697781)

  • 1. Ascending aortic aneurysm repair 44 years after Starr-Edwards caged-ball aortic valve replacement.
    Hatton GE; Tanaka A; Estrera AL
    Eur J Cardiothorac Surg; 2018 Nov; 54(5):962-963. PubMed ID: 29697781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ascending aortic aneurysm in a patient with an aortic Starr-Edwards ball valve prosthesis implanted 39 years previously.
    Nishigawa K; Totsugawa T; Yoshitaka H; Tsushima Y; Kuinose M; Chikazawa G
    Gen Thorac Cardiovasc Surg; 2010 Mar; 58(3):138-40. PubMed ID: 20349304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reoperation for aortic homograft failure using an Edwards Intuity valve.
    Folesani G; Calcara G; Minniti G; Polesel E
    Interact Cardiovasc Thorac Surg; 2016 Mar; 22(3):378-80. PubMed ID: 26675562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3D-printing assisted closure of paravalvular leak.
    Motwani M; Burley O; Luckie M; Cunnington C; Pisaniello AD; Hasan R; Malik I; Fraser DG
    J Cardiovasc Comput Tomogr; 2020; 14(5):e66-e68. PubMed ID: 30930181
    [No Abstract]   [Full Text] [Related]  

  • 5. Sutureless aortic bioprosthesis valve implantation and bicuspid valve anatomy: an unsolved dilemma?
    Vola M; Guichard JB; Campisi S; Fuzellier JF; Gerbay A; Doguet F; Isaaz K; Azarnoush K; Anselmi A; Ruggieri VG
    Heart Vessels; 2016 Nov; 31(11):1783-1789. PubMed ID: 26758734
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term prognosis of ascending aortic aneurysm after aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis.
    Girdauskas E; Disha K; Borger MA; Kuntze T
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):276-82. PubMed ID: 23246059
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Concomitant transapical treatment of aortic stenosis and degenerated mitral bioprosthesis with two 29 mm Edwards Sapien XT prostheses.
    Misuraca L; Farah B; Tchetche D
    J Invasive Cardiol; 2013 Dec; 25(12):680-2. PubMed ID: 24296390
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Congenital bicuspid pulmonary valve. An uncommon impede for Ross procedure.
    Kajingu Enciso S; Elens M; Rubay J
    Acta Chir Belg; 2017 Apr; 117(2):115-117. PubMed ID: 27549749
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aortic Valve Reoperation After Stentless Bioprosthesis: Short- and Long-Term Outcomes.
    Yang B; Patel HJ; Norton EL; Debenedictus C; Farhat L; Wu X; He K; Hornsby WE; Likosky DS; Deeb GM
    Ann Thorac Surg; 2018 Aug; 106(2):521-525. PubMed ID: 29625103
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulmonary autograft leaflet repair and valve sparing root replacement to correct late failure of the ross procedure.
    Goldstone AB; Woo YJ
    J Card Surg; 2013 Sep; 28(5):496-9. PubMed ID: 23782261
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bentall procedure 39 years after implantation of a Starr-Edwards aortic caged-ball-valve prosthesis.
    Schmitto JD; Ortmann P; Popov AF; Coskun KO; Schotola H; Friedrich M; Wiese CH; Sohns C; Mokashi SA; Didilis VN; Schoendube FA
    J Cardiothorac Surg; 2010 Mar; 5():12. PubMed ID: 20298579
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Apico-aortic valved conduit as an alternative for aortic valve re-replacement in severe prosthesis-patient mismatch.
    Chahine JH; El-Rassi I; Jebara V
    Interact Cardiovasc Thorac Surg; 2009 Oct; 9(4):680-2. PubMed ID: 19643802
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance profile of the Starr-Edwards aortic cloth covered valve, track valve, and silastic ball valve.
    Lund O; Pilegaard HK; Ilkjaer LB; Nielsen SL; Arildsen H; Albrechtsen OK
    Eur J Cardiothorac Surg; 1999 Oct; 16(4):403-13. PubMed ID: 10571086
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Late Contained Aortic Root Rupture After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis.
    Ochiai T; Yoon SH; Flint N; Sharma R; Patel C; Patel V; Chakravarty T; Nakamura M; Cheng W; Makkar R
    JACC Cardiovasc Interv; 2019 Jul; 12(14):e121-e122. PubMed ID: 31255557
    [No Abstract]   [Full Text] [Related]  

  • 15. Remodeling root repair with an external aortic ring annuloplasty.
    Lansac E; Di Centa I; Sleilaty G; Lejeune S; Berrebi A; Zacek P; Debauchez M
    J Thorac Cardiovasc Surg; 2017 May; 153(5):1033-1042. PubMed ID: 28187973
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Late surgical explantation and aortic valve replacement after transcatheter aortic valve implantation.
    Wang LW; Granger EK; McCourt JA; Pye R; Kaplan JM; Muller DW
    Ann Thorac Surg; 2015 Apr; 99(4):1434-6. PubMed ID: 25841830
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Valve-sparing root replacement after prior Starr-Edwards aortic valve replacement.
    Reade CC; Kypson AP; Williams JM
    J Heart Valve Dis; 2005 Sep; 14(5):695-6. PubMed ID: 16245511
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aberrant right coronary artery in a grown up congenital cardiac patient, successfully treated 46 years earlier with a double Starr-Edwards silastic ball valve replacement: a case report.
    Ponsiglione A; Spagnuolo G; Spagnuolo G; Stanzione A; Nappi C; Dell'Aversana S; Spagnuolo A; Cuocolo A; Imbriaco M
    BMC Cardiovasc Disord; 2020 Jan; 20(1):37. PubMed ID: 31996146
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early structural valve deterioration of the Trifecta aortic valve biological prosthesis: a word of caution.
    Saxena P; Greason KL; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):e10-1. PubMed ID: 24041765
    [No Abstract]   [Full Text] [Related]  

  • 20. Percutaneous treatment of late complications of the Bentall procedure.
    Delorme S; Ruchat P; Goy JJ
    Catheter Cardiovasc Interv; 2018 Aug; 92(2):348-352. PubMed ID: 28296051
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.