These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 29702387)

  • 1. Multifunctional 3D electrode platform for real-time in situ monitoring and stimulation of cardiac tissues.
    Zhang N; Stauffer F; Simona BR; Zhang F; Zhang ZM; Huang NP; Vörös J
    Biosens Bioelectron; 2018 Jul; 112():149-155. PubMed ID: 29702387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of cellular impedance measures of cardiomyocyte cultures for drug screening applications.
    Peters MF; Scott CW; Ochalski R; Dragan YP
    Assay Drug Dev Technol; 2012 Dec; 10(6):525-32. PubMed ID: 22574652
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Drug-induced functional cardiotoxicity screening in stem cell-derived human and mouse cardiomyocytes: effects of reference compounds.
    Himmel HM
    J Pharmacol Toxicol Methods; 2013; 68(1):97-111. PubMed ID: 23702537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Beating heart on a chip: a novel microfluidic platform to generate functional 3D cardiac microtissues.
    Marsano A; Conficconi C; Lemme M; Occhetta P; Gaudiello E; Votta E; Cerino G; Redaelli A; Rasponi M
    Lab Chip; 2016 Feb; 16(3):599-610. PubMed ID: 26758922
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hydrogel Microchambers Integrated with Organic Electrodes for Efficient Electrical Stimulation of Human iPSC-Derived Cardiomyocytes.
    Yoshida S; Sumomozawa K; Nagamine K; Nishizawa M
    Macromol Biosci; 2019 Jun; 19(6):e1900060. PubMed ID: 31038841
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flexible multichannel vagus nerve electrode for stimulation and recording for heart failure treatment.
    Xue N; Martinez ID; Sun J; Cheng Y; Liu C
    Biosens Bioelectron; 2018 Jul; 112():114-119. PubMed ID: 29702382
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Contractile properties of early human embryonic stem cell-derived cardiomyocytes: beta-adrenergic stimulation induces positive chronotropy and lusitropy but not inotropy.
    Pillekamp F; Haustein M; Khalil M; Emmelheinz M; Nazzal R; Adelmann R; Nguemo F; Rubenchyk O; Pfannkuche K; Matzkies M; Reppel M; Bloch W; Brockmeier K; Hescheler J
    Stem Cells Dev; 2012 Aug; 21(12):2111-21. PubMed ID: 22268955
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a Next-Generation Biosensing Platform for Simultaneous Detection of Mechano- and Electrophysiology of the Drug-Induced Cardiomyocytes.
    Oyunbaatar NE; Dai Y; Shanmugasundaram A; Lee BK; Kim ES; Lee DW
    ACS Sens; 2019 Oct; 4(10):2623-2630. PubMed ID: 31535848
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-throughput rhythmic regulation of cardiomyocytes by integrated electrical stimulation and video-based automated analysis biosensing platform.
    Liu J; Wang H; Xu D; Li Y; Fang J; Zhang M; Xia Q; Huang Z; Cao N; Hu N; Guo J
    Biosens Bioelectron; 2022 Aug; 209():114252. PubMed ID: 35405502
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 3D cardiac μtissues within a microfluidic device with real-time contractile stress readout.
    Aung A; Bhullar IS; Theprungsirikul J; Davey SK; Lim HL; Chiu YJ; Ma X; Dewan S; Lo YH; McCulloch A; Varghese S
    Lab Chip; 2016 Jan; 16(1):153-62. PubMed ID: 26588203
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous contractile force and electrical signal recordings of 3D cardiac tissue utilizing conductive hydrogel pillars on a chip.
    Zhang F; Cheng H; Qu K; Qian X; Lin Y; Zhang Y; Qian S; Huang N; Cui C; Chen M
    Mater Today Bio; 2023 Jun; 20():100626. PubMed ID: 37122834
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Micro-patterned SU-8 cantilever integrated with metal electrode for enhanced electromechanical stimulation of cardiac cells.
    Oyunbaatar NE; Shanmugasundaram A; Jeong YJ; Lee BK; Kim ES; Lee DW
    Colloids Surf B Biointerfaces; 2020 Feb; 186():110682. PubMed ID: 31846891
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In situ diagnosis and simultaneous treatment of cardiac diseases using a single-device platform.
    Hwang JC; Kim M; Kim S; Seo H; An S; Jang EH; Han SY; Kim MJ; Kim NK; Cho SW; Lee S; Park JU
    Sci Adv; 2022 Sep; 8(37):eabq0897. PubMed ID: 36103536
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microfabricated perfusable cardiac biowire: a platform that mimics native cardiac bundle.
    Xiao Y; Zhang B; Liu H; Miklas JW; Gagliardi M; Pahnke A; Thavandiran N; Sun Y; Simmons C; Keller G; Radisic M
    Lab Chip; 2014 Mar; 14(5):869-82. PubMed ID: 24352498
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of field potential duration on spontaneous beating rate of human induced pluripotent stem cell-derived cardiomyocytes: Implications for data analysis and test system selection.
    Rast G; Kraushaar U; Buckenmaier S; Ittrich C; Guth BD
    J Pharmacol Toxicol Methods; 2016; 82():74-82. PubMed ID: 27521052
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A microscale biomimetic platform for generation and electro-mechanical stimulation of 3D cardiac microtissues.
    Visone R; Talò G; Occhetta P; Cruz-Moreira D; Lopa S; Pappalardo OA; Redaelli A; Moretti M; Rasponi M
    APL Bioeng; 2018 Dec; 2(4):046102. PubMed ID: 31069324
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An extracellular microelectrode array for monitoring electrogenic cells in culture.
    Connolly P; Clark P; Curtis AS; Dow JA; Wilkinson CD
    Biosens Bioelectron; 1990; 5(3):223-34. PubMed ID: 2206490
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interdigitated array of Pt electrodes for electrical stimulation and engineering of aligned muscle tissue.
    Ahadian S; Ramón-Azcón J; Ostrovidov S; Camci-Unal G; Hosseini V; Kaji H; Ino K; Shiku H; Khademhosseini A; Matsue T
    Lab Chip; 2012 Sep; 12(18):3491-503. PubMed ID: 22847280
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A closed-loop electrical stimulation system for cardiac cell cultures.
    Whittington RH; Giovangrandi L; Kovacs GT
    IEEE Trans Biomed Eng; 2005 Jul; 52(7):1261-70. PubMed ID: 16041989
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microfabrication of a platform to measure and manipulate the mechanics of engineered microtissues.
    Ramade A; Legant WR; Picart C; Chen CS; Boudou T
    Methods Cell Biol; 2014; 121():191-211. PubMed ID: 24560511
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.