BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 29704127)

  • 1. Correlation between femoral offset loss and dynamic hip screw cut-out complications after pertrochanteric fractures: a case-control study.
    Boukebous B; Guillon P; Vandenbussche E; Rousseau MA
    Eur J Orthop Surg Traumatol; 2018 Oct; 28(7):1321-1326. PubMed ID: 29704127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Femoral offset loss and internal arch restoration defect are correlated with intramedullary nail cut-out complications after pertrochanteric fractures: a case-control study.
    Boukebous B; Flouzat-Lachaniette CH; Donadio J; Chenguel Z; Guillon P; Rousseau MA
    Eur J Orthop Surg Traumatol; 2019 Oct; 29(7):1451-1460. PubMed ID: 31256289
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures.
    Stern R; Lübbeke A; Suva D; Miozzari H; Hoffmeyer P
    Int Orthop; 2011 Dec; 35(12):1855-61. PubMed ID: 21387175
    [TBL] [Abstract][Full Text] [Related]  

  • 4. PFNA and DHS for AO/OTA 31-A2 fractures: radiographic measurements, morbidity and mortality.
    Müller F; Doblinger M; Kottmann T; Füchtmeier B
    Eur J Trauma Emerg Surg; 2020 Oct; 46(5):947-953. PubMed ID: 31673714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Late postoperative analysis of the tip-apex distance (TAD) in pertrochanteric fractures: is there an accommodation of the implant within the bone?
    Aihara LJ; Nanni RA; Carvalho MS; Zamboni C; Durigan JR; Hungria Neto JS; Mercadante MT; Christian RW; Hungria JOS
    Injury; 2017 Oct; 48 Suppl 4():S54-S56. PubMed ID: 29145969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Pertrochanteric fractures: a randomized prospective study comparing dynamic screw plate and intramedullary fixation].
    Giraud B; Dehoux E; Jovenin N; Madi K; Harisboure A; Usandizaga G; Segal P
    Rev Chir Orthop Reparatrice Appar Mot; 2005 Dec; 91(8):732-6. PubMed ID: 16552995
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 130- versus 135-degree sliding hip screws and failure in pertrochanteric hip fractures.
    Radic R; Yates PJ; Lim TS; Burrows S
    ANZ J Surg; 2014 Dec; 84(12):949-54. PubMed ID: 24898151
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Complications of dynamic hip screw treatment for proximal femoral fractures].
    Hrubina M; Skoták M; Běhounek J
    Acta Chir Orthop Traumatol Cech; 2010 Oct; 77(5):395-401. PubMed ID: 21040651
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Outcomes of dynamic hip screw augmented with trochanteric wiring for treatment of unstable type A2 intertrochanteric femur fractures.
    Puram C; Pradhan C; Patil A; Sodhai V; Sancheti P; Shyam A
    Injury; 2017 Aug; 48 Suppl 2():S72-S77. PubMed ID: 28802425
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk factors for cut-out after internal fixation of trochanteric fractures in elderly subjects.
    Morvan A; Boddaert J; Cohen-Bittan J; Picard H; Pascal-Mousselard H; Khiami F
    Orthop Traumatol Surg Res; 2018 Dec; 104(8):1183-1187. PubMed ID: 30342858
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw.
    Madsen JE; Naess L; Aune AK; Alho A; Ekeland A; Strømsøe K
    J Orthop Trauma; 1998 May; 12(4):241-8. PubMed ID: 9619458
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dynamic Hip Screw Fixation Vs. Proximal Femur Nail For Unstable Per-Trochanteric Fractures: A Comparative Analysis Of Outcomes And Complications.
    Memon K; Siddiqui AM; Khan ZA; Zahoor A
    J Ayub Med Coll Abbottabad; 2021; 33(1):34-38. PubMed ID: 33774951
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures.
    Andruszkow H; Frink M; Frömke C; Matityahu A; Zeckey C; Mommsen P; Suntardjo S; Krettek C; Hildebrand F
    Int Orthop; 2012 Nov; 36(11):2347-54. PubMed ID: 23011721
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Trochanteric femoral fractures].
    Douša P; Čech O; Weissinger M; Džupa V
    Acta Chir Orthop Traumatol Cech; 2013; 80(1):15-26. PubMed ID: 23452417
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.
    Paulsson J; Stig JC; Olsson O
    BMC Musculoskelet Disord; 2017 Aug; 18(1):364. PubMed ID: 28836973
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Surgical outcome in pertrochanteric femur fracture: the impact of osteoporosis. Comparison between DHS and percutaneous compression plate].
    Knobe M; Münker R; Schmidt-Rohlfing B; Sellei RM; Schubert H; Erli HJ
    Z Orthop Unfall; 2008; 146(1):44-51. PubMed ID: 18324581
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.
    Wirtz C; Abbassi F; Evangelopoulos DS; Kohl S; Siebenrock KA; Krüger A
    Injury; 2013 Jun; 44(6):751-6. PubMed ID: 23522837
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Hip fractures].
    Weisová D; Salášek M; Pavelka T
    Cas Lek Cesk; 2013; 152(5):219-25. PubMed ID: 24131459
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Dynamic Hip Screw Osteosynthesis for Proximal Femoral Fractures in Patients with Coxarthrosis].
    Hrubina M; Skoták M; Letocha J
    Acta Chir Orthop Traumatol Cech; 2015; 82(5):364-8. PubMed ID: 26516955
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Additional fixations for sliding hip screws in treating unstable pertrochanteric femoral fractures (AO Type 31-A2): short-term clinical results.
    Cho SH; Lee SH; Cho HL; Ku JH; Choi JH; Lee AJ
    Clin Orthop Surg; 2011 Jun; 3(2):107-13. PubMed ID: 21629470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.