These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
315 related articles for article (PubMed ID: 29704706)
21. Design and simulation of a full-ring multi-lofthole collimator for brain SPECT. Van Audenhaege K; Vandenberghe S; Deprez K; Vandeghinste B; Van Holen R Phys Med Biol; 2013 Sep; 58(18):6317-36. PubMed ID: 23966017 [TBL] [Abstract][Full Text] [Related]
22. Monte carlo study of the effect of collimator thickness on T-99m source response in single photon emission computed tomography. Islamian JP; Toossi MT; Momennezhad M; Zakavi SR; Sadeghi R; Ljungberg M World J Nucl Med; 2012 May; 11(2):70-4. PubMed ID: 23372440 [TBL] [Abstract][Full Text] [Related]
23. Evaluation of tomographic image quality of extended and conventional parallel hole collimators using maximum likelihood expectation maximization algorithm by Monte Carlo simulations. Moslemi V; Ashoor M Nucl Med Commun; 2017 Oct; 38(10):843-853. PubMed ID: 28800003 [TBL] [Abstract][Full Text] [Related]
24. Primary, scatter, and penetration characterizations of parallel-hole and pinhole collimators for I-123 SPECT. Könik A; Auer B; De Beenhouwer J; Kalluri K; Zeraatkar N; Furenlid LR; King MA Phys Med Biol; 2019 Dec; 64(24):245001. PubMed ID: 31746783 [TBL] [Abstract][Full Text] [Related]
25. An energy-optimized collimator design for a CZT-based SPECT camera. Weng F; Bagchi S; Zan Y; Huang Q; Seo Y Nucl Instrum Methods Phys Res A; 2016 Jan; 806():330-339. PubMed ID: 26640308 [TBL] [Abstract][Full Text] [Related]
26. A Monte Carlo study for optimizing the detector of SPECT imaging using a XCAT human phantom. Khoshakhlagh M; Pirayesh Islamian J; Abedi SM; Mahmoudian B; Shayesteh Azar M Nucl Med Rev Cent East Eur; 2017; 20(1):10-14. PubMed ID: 28198517 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation. Deloar HM; Watabe H; Aoi T; Iida H Phys Med Biol; 2003 Apr; 48(8):995-1008. PubMed ID: 12741497 [TBL] [Abstract][Full Text] [Related]
28. Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging. Janssen JP; Hoffmann JV; Kanno T; Nose N; Grunz JP; Onoguchi M; Chen X; Lapa C; Buck AK; Higuchi T Sci Rep; 2020 Oct; 10(1):18616. PubMed ID: 33122774 [TBL] [Abstract][Full Text] [Related]
29. Slit slat collimator optimization with respect to MTF. Kamali-Asl A; Sarkar S; Shahriari M; Agha-Hosseini H Appl Radiat Isot; 2005 Mar; 62(3):461-8. PubMed ID: 15607925 [TBL] [Abstract][Full Text] [Related]
30. Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations. Mao Y; Yu Z; Zeng GL Med Phys; 2015 Sep; 42(9):5426-34. PubMed ID: 26328991 [TBL] [Abstract][Full Text] [Related]
31. Esquinas PL; Rodríguez-Rodríguez C; Carlos De La Vega J; Bokharaei M; Saatchi K; Shirmohammad M; Häfeli UO; Sossi V; Celler A Phys Med; 2017 Jan; 33():26-37. PubMed ID: 28007432 [TBL] [Abstract][Full Text] [Related]
32. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks. Ghaly M; Du Y; Links JM; Frey EC Phys Med Biol; 2016 Mar; 61(5):2048-66. PubMed ID: 26895287 [TBL] [Abstract][Full Text] [Related]
33. Design and performance evaluation of a new high energy parallel hole collimator for radioiodine planar imaging by gamma cameras: Monte Carlo simulation study. Moslemi V; Ashoor M Ann Nucl Med; 2017 May; 31(4):324-334. PubMed ID: 28275975 [TBL] [Abstract][Full Text] [Related]
34. SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators. Van Holen R; Staelens S; Vandenberghe S Med Phys; 2009 Sep; 36(9):4257-67. PubMed ID: 19810500 [TBL] [Abstract][Full Text] [Related]
35. Monte Carlo simulation of the basic features of the GE Millennium MG single photon emission computed tomography gamma camera. Vieira L; Vaz TF; Costa DC; Almeida P Rev Esp Med Nucl Imagen Mol; 2014; 33(1):6-13. PubMed ID: 23726248 [TBL] [Abstract][Full Text] [Related]
36. Monte Carlo modeling of gamma cameras for I-131 imaging in targeted radiotherapy. Autret D; Bitar A; Ferrer L; Lisbona A; Bardiès M Cancer Biother Radiopharm; 2005 Feb; 20(1):77-84. PubMed ID: 15778585 [TBL] [Abstract][Full Text] [Related]
37. Dual-layer collimator for improved spatial resolution in SPECT with CZT camera: an analytical and Monte Carlo study. Boutaghane N; Hesse M; Bouzid B; Zaidi H; Jamar F; Walrand S Phys Med Biol; 2022 Mar; 67(6):. PubMed ID: 35176729 [No Abstract] [Full Text] [Related]
38. Initial clinical experience with dedicated multi-pinhole (MPH) collimator for Képes Z; Kukuts K; Oszlánszki A; Mihovk I; Krizsán Á; Barna S; Robinson A; Deidda D; Mester J; Varga J; Garai I; Forgács A Hell J Nucl Med; 2022; 25(2):143-147. PubMed ID: 35913861 [TBL] [Abstract][Full Text] [Related]
39. Collimator design for a multipinhole brain SPECT insert for MRI. Van Audenhaege K; Van Holen R; Vanhove C; Vandenberghe S Med Phys; 2015 Nov; 42(11):667989. PubMed ID: 26520758 [TBL] [Abstract][Full Text] [Related]
40. Monte Carlo simulation of PET and SPECT imaging of 90Y. Takahashi A; Himuro K; Yamashita Y; Komiya I; Baba S; Sasaki M Med Phys; 2015 Apr; 42(4):1926-35. PubMed ID: 25832083 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]