152 related articles for article (PubMed ID: 29705115)
21. Effects of tactile stimulation on spontaneous breathing during face mask ventilation.
Gaertner VD; Rüegger CM; Bassler D; O'Currain E; Kamlin COF; Hooper SB; Davis PG; Springer L
Arch Dis Child Fetal Neonatal Ed; 2022 Sep; 107(5):508-512. PubMed ID: 34862191
[TBL] [Abstract][Full Text] [Related]
22. Airway obstruction during mask ventilation of very low birth weight infants during neonatal resuscitation.
Finer NN; Rich W; Wang C; Leone T
Pediatrics; 2009 Mar; 123(3):865-9. PubMed ID: 19255015
[TBL] [Abstract][Full Text] [Related]
23. Face mask versus nasal prong or nasopharyngeal tube for neonatal resuscitation in the delivery room: a systematic review and meta-analysis.
Mangat A; Bruckner M; Schmölzer GM
Arch Dis Child Fetal Neonatal Ed; 2021 Sep; 106(5):561-567. PubMed ID: 33504574
[TBL] [Abstract][Full Text] [Related]
24. Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure ventilation.
Schettino GP; Chatmongkolchart S; Hess DR; Kacmarek RM
Crit Care Med; 2003 Aug; 31(8):2178-82. PubMed ID: 12973177
[TBL] [Abstract][Full Text] [Related]
25. Compromised pressure and flow during suction mask ventilation.
Rüegger CM; O'Currain E; Dawson JA; Davis PG; Kamlin COF; Lorenz L
Arch Dis Child Fetal Neonatal Ed; 2019 Nov; 104(6):F662-F663. PubMed ID: 30824473
[No Abstract] [Full Text] [Related]
26. Decrease in delivery room intubation rates after use of nasal intermittent positive pressure ventilation in the delivery room for resuscitation of very low birth weight infants.
Biniwale M; Wertheimer F
Resuscitation; 2017 Jul; 116():33-38. PubMed ID: 28476473
[TBL] [Abstract][Full Text] [Related]
27. Volume-targeted mask ventilation during simulated neonatal resuscitation.
Law BHY; Schmölzer GM
Arch Dis Child Fetal Neonatal Ed; 2024 Feb; 109(2):217-220. PubMed ID: 37775257
[TBL] [Abstract][Full Text] [Related]
28. Neonatal ventilation with a manikin model and two novel PEEP valves without an external gas source.
Thallinger M; Ersdal HL; Morley C; Purington C; Gomo Ø; Mduma E; Eilevstjønn J; Størdal K
Arch Dis Child Fetal Neonatal Ed; 2017 May; 102(3):F208-F213. PubMed ID: 27573519
[TBL] [Abstract][Full Text] [Related]
29. Comparison of devices for newborn ventilation in the delivery room.
Szyld E; Aguilar A; Musante GA; Vain N; Prudent L; Fabres J; Carlo WA;
J Pediatr; 2014 Aug; 165(2):234-239.e3. PubMed ID: 24690329
[TBL] [Abstract][Full Text] [Related]
30. Tidal volumes during delivery room stabilization of (near) term infants.
Thomann J; Rüegger CM; Gaertner VD; O'Currain E; Kamlin OF; Davis PG; Springer L
BMC Pediatr; 2022 Sep; 22(1):543. PubMed ID: 36100886
[TBL] [Abstract][Full Text] [Related]
31. Positive pressure ventilation with the size 5 laryngeal mask.
Brimacombe JR
J Clin Anesth; 1997 Mar; 9(2):113-7. PubMed ID: 9075035
[TBL] [Abstract][Full Text] [Related]
32. Monitoring tidal volumes in preterm infants at birth: mask versus endotracheal ventilation.
van Vonderen JJ; Hooper SB; Krabbe VB; Siew ML; Te Pas AB
Arch Dis Child Fetal Neonatal Ed; 2015 Jan; 100(1):F43-6. PubMed ID: 25240050
[TBL] [Abstract][Full Text] [Related]
33. [The effects of endotracheal suction on gas exchange and respiratory mechanics in mechanically ventilated patients under pressure-controlled or volume-controlled ventilation].
Liu XW; Liu Z
Zhonghua Jie He He Hu Xi Za Zhi; 2007 Oct; 30(10):751-5. PubMed ID: 18218205
[TBL] [Abstract][Full Text] [Related]
34. Comparisons of predictive performance of breathing pattern variability measured during T-piece, automatic tube compensation, and pressure support ventilation for weaning intensive care unit patients from mechanical ventilation.
Bien MY; Shui Lin Y; Shih CH; Yang YL; Lin HW; Bai KJ; Wang JH; Ru Kou Y
Crit Care Med; 2011 Oct; 39(10):2253-62. PubMed ID: 21666447
[TBL] [Abstract][Full Text] [Related]
35. Basic life support trained nurses ventilate more efficiently with laryngeal mask supreme than with facemask or laryngeal tube suction-disposable--a prospective, randomized clinical trial.
Gruber E; Oberhammer R; Balkenhol K; Strapazzon G; Procter E; Brugger H; Falk M; Paal P
Resuscitation; 2014 Apr; 85(4):499-502. PubMed ID: 24440666
[TBL] [Abstract][Full Text] [Related]
36. Initial stabilisation of preterm infants: a new resuscitation system with low imposed work of breathing for use with face mask or nasal prongs.
Donaldsson S; Drevhammar T; Taittonen L; Klemming S; Jonsson B
Arch Dis Child Fetal Neonatal Ed; 2017 May; 102(3):F203-F207. PubMed ID: 27553588
[TBL] [Abstract][Full Text] [Related]
37. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?
Maheshwari R; Tracy M; Hinder M; Wright A
J Paediatr Child Health; 2017 Aug; 53(8):761-765. PubMed ID: 28675548
[TBL] [Abstract][Full Text] [Related]
38. A Randomized Controlled Trial of End-Tidal Carbon Dioxide Detection of Preterm Infants in the Delivery Room.
Hawkes GA; Finn D; Kenosi M; Livingstone V; O'Toole JM; Boylan GB; O'Halloran KD; Ryan AC; Dempsey EM
J Pediatr; 2017 Mar; 182():74-78.e2. PubMed ID: 27939108
[TBL] [Abstract][Full Text] [Related]
39. Assessing the effectiveness of two round neonatal resuscitation masks: study 1.
Wood FE; Morley CJ; Dawson JA; Kamlin CO; Owen LS; Donath S; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2008 May; 93(3):F235-7. PubMed ID: 18039749
[TBL] [Abstract][Full Text] [Related]
40. Delivery room continuous positive airway pressure/positive end-expiratory pressure in extremely low birth weight infants: a feasibility trial.
Finer NN; Carlo WA; Duara S; Fanaroff AA; Donovan EF; Wright LL; Kandefer S; Poole WK;
Pediatrics; 2004 Sep; 114(3):651-7. PubMed ID: 15342835
[TBL] [Abstract][Full Text] [Related]