These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 29715936)

  • 1. Laboratory demonstration of a broadband six-level phase mask coronagraph.
    Patru F; Baudoz P; Galicher R; Cao Q; Wang K; Xing L; Boussaha F; Firminy J; Bonafous M
    Opt Express; 2018 Apr; 26(8):10007-10012. PubMed ID: 29715936
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance characterization of a broadband vector Apodizing Phase Plate coronagraph.
    Otten GP; Snik F; Kenworthy MA; Miskiewicz MN; Escuti MJ
    Opt Express; 2014 Dec; 22(24):30287-314. PubMed ID: 25606959
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 10(-7) contrast ratio at 4.5lambda/D: New results obtained in laboratory experiments using nano-fabricated coronagraph and multi-Gaussian shaped pupil masks.
    Chakraborty A; Thompson L; Rogosky M
    Opt Express; 2005 Apr; 13(7):2394-402. PubMed ID: 19495130
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimal pupil basis set for telescope-coronagraph design and perturbation analysis based on the method of moments.
    Yan S; Chen P; Wade MI; Gill TL
    J Opt Soc Am A Opt Image Sci Vis; 2022 Dec; 39(12):2422-2436. PubMed ID: 36520765
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Band-limited image plane masks for the Terrestrial Planet Finder coronagraph: materials and designs for broadband performance.
    Balasubramanian K
    Appl Opt; 2008 Jan; 47(2):116-25. PubMed ID: 18188191
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wide-band six-region phase mask coronagraph.
    Hou F; Cao Q; Zhu M; Ma O
    Opt Express; 2014 Jan; 22(2):1884-95. PubMed ID: 24515197
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cascade six-level phase-mask achromatic coronagraph.
    Ge Y; Cao Q; Hu R; Wang K; Tong X
    Appl Opt; 2016 Feb; 55(5):1006-11. PubMed ID: 26906367
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Super-Gaussian apodization in ground based telescopes for high contrast coronagraph imaging.
    Cagigas MA; Valle PJ; Cagigal MP
    Opt Express; 2013 May; 21(10):12744-56. PubMed ID: 23736492
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of a coronagraphic mask using evanescent waves.
    Buisset C; Rabbia Y; Lepine T; Alagao MA; Ducrot E; Poshyachinda S; Soonthornthum B
    Opt Express; 2017 Apr; 25(7):7273-7287. PubMed ID: 28380852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wide-band coronagraph with sinusoidal phase in the angular direction.
    Ma O; Cao Q; Hou F
    Opt Express; 2012 May; 20(10):10933-43. PubMed ID: 22565717
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pupil stabilization for SPHERE's extreme AO and high performance coronagraph system.
    Montagnier G; Fusco T; Beuzit JL; Mouillet D; Charton J; Jocou L
    Opt Express; 2007 Nov; 15(23):15293-307. PubMed ID: 19550815
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Propagation of aberrations through phase-induced amplitude apodization coronagraph.
    Pueyo L; Kasdin NJ; Shaklan S
    J Opt Soc Am A Opt Image Sci Vis; 2011 Feb; 28(2):189-202. PubMed ID: 21293522
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and fabrication of broadband guided-mode resonant reflectors in TE polarization.
    Khaleque T; Uddin MJ; Magnusson R
    Opt Express; 2014 May; 22(10):12349-58. PubMed ID: 24921353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Polarization interferometric nulling coronagraph for high-contrast imaging.
    Murakami N; Yokochi K; Nishikawa J; Tamura M; Kurokawa T; Takeda M; Baba N
    Appl Opt; 2010 Jun; 49(16):D106-14. PubMed ID: 20517351
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Requirements on optical density and phase dispersion of imperfect band-limited occulting masks in a broadband coronagraph.
    Sidick E
    Appl Opt; 2007 Oct; 46(30):7485-93. PubMed ID: 17952186
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reflectivity and optical surface height requirements in a broadband coronagraph. 1. Contrast floor due to controllable spatial frequencies.
    Shaklan SB; Green JJ
    Appl Opt; 2006 Jul; 45(21):5143-53. PubMed ID: 16826252
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A laboratory demonstration of the capability to image an Earth-like extrasolar planet.
    Trauger JT; Traub WA
    Nature; 2007 Apr; 446(7137):771-3. PubMed ID: 17429394
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimal design of the annular groove phase mask central region.
    König L; Absil O; Lobet M; Delacroix C; Karlsson M; Orban de Xivry G; Loicq J
    Opt Express; 2022 Jul; 30(15):27048-27063. PubMed ID: 36236884
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Speckle-phase measurement in a tandem-vortex coronagraph.
    Serabyn E; Wallace JK; Mawet D
    Appl Opt; 2011 Oct; 50(28):5453-6. PubMed ID: 22016212
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved two-step optimization procedure used for designing an apodizer and Lyot stop in the Lyot coronagraph.
    Ge R; Zhao H; Wei JX; Duan YQ; Bai Z; Li C; Wang YB; Fan XW
    Appl Opt; 2020 Jun; 59(16):4939-4952. PubMed ID: 32543491
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.