346 related articles for article (PubMed ID: 29717360)
21. Dual-Wavelength Ratiometric Electrochemiluminescence Immunosensor for Cardiac Troponin I Detection.
Ye J; Zhu L; Yan M; Zhu Q; Lu Q; Huang J; Cui H; Yang X
Anal Chem; 2019 Jan; 91(2):1524-1531. PubMed ID: 30547579
[TBL] [Abstract][Full Text] [Related]
22. Cathodic electrochemiluminescence immunosensor based on nanocomposites of semiconductor carboxylated g-C3N4 and graphene for the ultrasensitive detection of squamous cell carcinoma antigen.
Li X; Zhang X; Ma H; Wu D; Zhang Y; Du B; Wei Q
Biosens Bioelectron; 2014 May; 55():330-6. PubMed ID: 24412767
[TBL] [Abstract][Full Text] [Related]
23. A novel anodic electrochemiluminescence behavior of sulfur-doped carbon nitride nanosheets in the presence of nitrogen-doped carbon dots and its application for detecting folic acid.
Zhu R; Zhang Y; Wang J; Yue C; Fang W; Dang J; Zhao H; Li Z
Anal Bioanal Chem; 2019 Nov; 411(27):7137-7146. PubMed ID: 31511944
[TBL] [Abstract][Full Text] [Related]
24. An "on-off" electrochemiluminescence immunosensor for PIVKA-II detection based on the dual quenching of CeO
Ai Z; Zhao M; Han D; Chen K; Xiong D; Tang H
Biosens Bioelectron; 2021 May; 179():113059. PubMed ID: 33561664
[TBL] [Abstract][Full Text] [Related]
25. Aptamer based electrochemiluminescent determination of bisphenol A by using carboxylated graphitic carbon nitride.
Cao HX; Wang L; Pan CG; He YS; Liang GX
Mikrochim Acta; 2018 Sep; 185(10):463. PubMed ID: 30225568
[TBL] [Abstract][Full Text] [Related]
26. A Solid-state Electrochemiluminescence Sensor for Detecting Glutathione with a Graphite-phase Carbon Nitride/Silica Modified Glassy Carbon Electrode.
Shan X; Shan X; Pan T; Dai F; Chen X; Wang W; Chen Z
Anal Sci; 2019 Dec; 35(12):1299-1304. PubMed ID: 31308299
[TBL] [Abstract][Full Text] [Related]
27. Ultrasensitive dual-quenching electrochemiluminescence immunosensor for prostate specific antigen detection based on graphitic carbon nitride quantum dots as an emitter.
Liu P; Meng H; Zhang G; Song L; Han Q; Wang C; Fu Y
Mikrochim Acta; 2021 Sep; 188(10):350. PubMed ID: 34554330
[TBL] [Abstract][Full Text] [Related]
28. Electrochemiluminescence energy resonance transfer in 2D/2D heterostructured g-C
Fu XL; Hou F; Liu FR; Ren SW; Cao JT; Liu YM
Biosens Bioelectron; 2019 Mar; 129():72-78. PubMed ID: 30684857
[TBL] [Abstract][Full Text] [Related]
29. Electrochemiluminescence immunoassay for the N-terminal pro-B-type natriuretic peptide based on resonance energy transfer between a self-enhanced luminophore composed of silver nanocubes on gold nanoparticles and a metal-organic framework of type MIL-125.
Dong X; Zhao G; Li X; Miao J; Fang J; Wei Q; Cao W
Mikrochim Acta; 2019 Nov; 186(12):811. PubMed ID: 31745662
[TBL] [Abstract][Full Text] [Related]
30. Electrochemiluminescence behaviour of silver/silver orthophosphate/graphene oxide quenched by Pd@Au core-shell nanoflowers for ultrasensitive detection of insulin.
Khan MS; Ameer H; Ali A; Manzoor R; Yang L; Feng R; Jiang N; Wei Q
Biosens Bioelectron; 2020 Jan; 147():111767. PubMed ID: 31655384
[TBL] [Abstract][Full Text] [Related]
31. A colorimetric mercury(II) assay based on the Hg(II)-stimulated peroxidase mimicking activity of a nanocomposite prepared from graphitic carbon nitride and gold nanoparticles.
Wang YW; Liu Q; Wang L; Tang S; Yang HH; Song H
Mikrochim Acta; 2018 Dec; 186(1):7. PubMed ID: 30535761
[TBL] [Abstract][Full Text] [Related]
32. Highly sensitive electrochemiluminescence detection of p53 protein using functionalized Ru-silica nanoporous@gold nanocomposite.
Afsharan H; Navaeipour F; Khalilzadeh B; Tajalli H; Mollabashi M; Ahar MJ; Rashidi MR
Biosens Bioelectron; 2016 Jun; 80():146-153. PubMed ID: 26827144
[TBL] [Abstract][Full Text] [Related]
33. Electrochemiluminescence sensor based on cyclic peptides-recognition and Au nanoparticles assisted graphitic carbon nitride for glucose determination.
Gu Y; Hu Y; Zhang F; Yi L; Shang Y; Ren D; Ge Z
Mikrochim Acta; 2021 Apr; 188(5):151. PubMed ID: 33813618
[TBL] [Abstract][Full Text] [Related]
34. A Novel Electrochemiluminescence Immunosensor for the Analysis of HIV-1 p24 Antigen Based on P-RGO@Au@Ru-SiO₂ Composite.
Zhou L; Huang J; Yu B; Liu Y; You T
ACS Appl Mater Interfaces; 2015 Nov; 7(44):24438-45. PubMed ID: 26488492
[TBL] [Abstract][Full Text] [Related]
35. An ultrasensitive luminol cathodic electrochemiluminescence immunosensor based on glucose oxidase and nanocomposites: graphene-carbon nanotubes and gold-platinum alloy.
Jiang X; Chai Y; Yuan R; Cao Y; Chen Y; Wang H; Gan X
Anal Chim Acta; 2013 Jun; 783():49-55. PubMed ID: 23726099
[TBL] [Abstract][Full Text] [Related]
36. A signal-on electrochemiluminescence biosensor for detecting Con A using phenoxy dextran-graphite-like carbon nitride as signal probe.
Ou X; Tan X; Liu X; Lu Q; Chen S; Wei S
Biosens Bioelectron; 2015 Aug; 70():89-97. PubMed ID: 25796041
[TBL] [Abstract][Full Text] [Related]
37. Electrochemiluminescent resonance energy transfer between amino-modified g-C
Ali A; Khan S; Li Z
Talanta; 2024 May; 271():125709. PubMed ID: 38290268
[TBL] [Abstract][Full Text] [Related]
38. Electrochemiluminescence Energy Resonance Transfer System between RuSi Nanoparticles and Hollow Au Nanocages for Nucleic Acid Detection.
Lu HJ; Pan JB; Wang YZ; Ji SY; Zhao W; Luo XL; Xu JJ; Chen HY
Anal Chem; 2018 Sep; 90(17):10434-10441. PubMed ID: 30073833
[TBL] [Abstract][Full Text] [Related]
39. Nitrogen-doped graphene quantum dots coated with gold nanoparticles for electrochemiluminescent glucose detection using enzymatically generated hydrogen peroxide as a quencher.
Ran P; Song J; Mo F; Wu J; Liu P; Fu Y
Mikrochim Acta; 2019 Apr; 186(5):276. PubMed ID: 30969371
[TBL] [Abstract][Full Text] [Related]
40. Ultrasensitive electrochemiluminescence immunoassay for tumor marker detection using functionalized Ru-silica@nanoporous gold composite as labels.
Zhang M; Ge S; Li W; Yan M; Song X; Yu J; Xu W; Huang J
Analyst; 2012 Feb; 137(3):680-5. PubMed ID: 22158639
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]