These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 29724)

  • 1. Eroneous temperature corrections for blood pH and gas measurements.
    Burnett RW
    Clin Chem; 1978 Oct; 24(10):1850. PubMed ID: 29724
    [No Abstract]   [Full Text] [Related]  

  • 2. The rapid processing of canine blood gas tension and pH measurements.
    Pickrell JA; Schluter SJ
    Am J Vet Res; 1973 Jan; 34(1):95-100. PubMed ID: 4683980
    [No Abstract]   [Full Text] [Related]  

  • 3. Calculations and correction factors used in determination of blood pH and blood gases.
    Burnett RW; Noonan DC
    Clin Chem; 1974 Dec; 20(12):1499-506. PubMed ID: 4609638
    [No Abstract]   [Full Text] [Related]  

  • 4. A critical evaluation of automated blood gas measurements in comparative respiratory physiology.
    Malte CL; Jakobsen SL; Wang T
    Comp Biochem Physiol A Mol Integr Physiol; 2014 Dec; 178():7-17. PubMed ID: 25088182
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrodes for the measurement of oxygen and carbon dioxide tensions.
    Smith AC; Hahn CE
    Br J Anaesth; 1969 Sep; 41(9):731-41. PubMed ID: 5353903
    [No Abstract]   [Full Text] [Related]  

  • 6. [Variation of blood gas partial pressure and pH in human blood during preservation at different temperatures. A contribution to the arrangement of correction factors for routine measurements].
    Arndt H; Buchta I; Baltzer G
    Respiration; 1968; 25(4):306-22. PubMed ID: 5652317
    [No Abstract]   [Full Text] [Related]  

  • 7. [Measurement of pH, pCO2, and pO2 using the IL meter under hypothermia].
    Ikeda S; Chikamitsu T; Kunitomi F; Kosaka N
    Masui; 1968 Jan; 17(1):26-32. PubMed ID: 5692105
    [No Abstract]   [Full Text] [Related]  

  • 8. Nomograms for the interdependence of P O2 , S O2 , P CO2 , C CO2 and pH in human blood at 28 and 32 degrees C.
    Grote J; Thews G; Wünscher WD
    Respiration; 1972; 29(3):193-205. PubMed ID: 5056758
    [No Abstract]   [Full Text] [Related]  

  • 9. A review of blood pH and blood-gas analysis.
    Beetham R
    Ann Clin Biochem; 1982 Jul; 19 (Pt 4)():198-213. PubMed ID: 6812483
    [No Abstract]   [Full Text] [Related]  

  • 10. [On the problem of the possibility of arterilization of venous blood in vivo for determination of pH, pCO2, and percent age saturation of 02 in persons with a healthy respiratory system].
    Redhammer R
    Bratisl Lek Listy; 1968 Dec; 50(6):729-38. PubMed ID: 5702265
    [No Abstract]   [Full Text] [Related]  

  • 11. [Effect of heparin on the result of pH and blood gas measurements. Study at 2 PCO2 and PO2 levels].
    Joly JB; Faussat AM; Chevrie J
    Pediatrie; 1973; 28(3):283-9. PubMed ID: 4726385
    [No Abstract]   [Full Text] [Related]  

  • 12. [Nomograms for the consideration of body temperature in blood gas and pH-measurements].
    Thews G
    Anaesthesist; 1972 Nov; 21(11):466-72. PubMed ID: 4646738
    [No Abstract]   [Full Text] [Related]  

  • 13. Normal arterial blood pH, oxygen, and carbon dioxide tensions in unanesthetized dogs.
    Feigl EO; D'Alecy LG
    J Appl Physiol; 1972 Jan; 32(1):152-3. PubMed ID: 5007010
    [No Abstract]   [Full Text] [Related]  

  • 14. The effect of cooling on blood gas tensions in newborn infants.
    Stephenson JM; Du JN; Oliver TK
    J Pediatr; 1970 Jun; 76(6):848-52. PubMed ID: 5444577
    [No Abstract]   [Full Text] [Related]  

  • 15. Quality-control system for blood pH and gas measurements, with use of a tonometered bicarbonate-chloride solution and duplicate samples of whole blood.
    Noonan DC; Burnett RW
    Clin Chem; 1974 Jun; 20(6):660-5. PubMed ID: 4830169
    [No Abstract]   [Full Text] [Related]  

  • 16. Nomograms for correction of blood Po2, Pco2, pH, and base excess for time and temperature.
    Kelman GR; Nunn JF
    J Appl Physiol; 1966 Sep; 21(5):1484-90. PubMed ID: 5923219
    [No Abstract]   [Full Text] [Related]  

  • 17. Monitoring venous pH and gas tensions during operations on infants and children.
    Grosfeld JL; O'Neill JA; Boles ET; Clatworthy HW
    Arch Surg; 1970 May; 100(5):584-8. PubMed ID: 5438573
    [No Abstract]   [Full Text] [Related]  

  • 18. Use of carbon dioxide- and oxygen-tonometered phosphate-bicarbonate-chloride-glycerol-water mixtures for calibration and control of pH, pCO2, and pO2 electrode systems.
    Veefkind AH; Van den Camp RA; Maas AH
    Clin Chem; 1975 May; 21(6):685-93. PubMed ID: 235377
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Determination of pO 2 , pCO 2 , pH on capillary blood].
    Flandrois R; Guérin JC; Kalb JC
    Poumon Coeur; 1971; 27(10):1069-77. PubMed ID: 5153288
    [No Abstract]   [Full Text] [Related]  

  • 20. pH and blood-gas analysis. Methods of measurement and sources of error using electrode systems.
    Adams AP; Morgan-Hughes JO; Sykes MK
    Anaesthesia; 1967 Oct; 22(4):575-97. PubMed ID: 6054558
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.