BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 29724014)

  • 21. Laser Doppler sensing for blood vessel detection with a biologically inspired steerable needle.
    Virdyawan V; Oldfield M; Rodriguez Y Baena F
    Bioinspir Biomim; 2018 Feb; 13(2):026009. PubMed ID: 29323660
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transurethral light delivery for prostate photoacoustic imaging.
    Lediju Bell MA; Guo X; Song DY; Boctor EM
    J Biomed Opt; 2015 Mar; 20(3):036002. PubMed ID: 25734406
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Non-invasive sentinel lymph node mapping and needle guidance using clinical handheld photoacoustic imaging system in small animal.
    Sivasubramanian K; Periyasamy V; Pramanik M
    J Biophotonics; 2018 Jan; 11(1):. PubMed ID: 28700132
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Photoacoustic imaging of clinical metal needles in tissue.
    Su J; Karpiouk A; Wang B; Emelianov S
    J Biomed Opt; 2010; 15(2):021309. PubMed ID: 20459231
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Convolution neural networks for real-time needle detection and localization in 2D ultrasound.
    Mwikirize C; Nosher JL; Hacihaliloglu I
    Int J Comput Assist Radiol Surg; 2018 May; 13(5):647-657. PubMed ID: 29512006
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging.
    Daoudi K; van den Berg PJ; Rabot O; Kohl A; Tisserand S; Brands P; Steenbergen W
    Opt Express; 2014 Oct; 22(21):26365-74. PubMed ID: 25401669
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Linear array-based real-time photoacoustic imaging system with a compact coaxial excitation handheld probe for noninvasive sentinel lymph node mapping.
    Li M; Liu C; Gong X; Zheng R; Bai Y; Xing M; Du X; Liu X; Zeng J; Lin R; Zhou H; Wang S; Lu G; Zhu W; Fang C; Song L
    Biomed Opt Express; 2018 Apr; 9(4):1408-1422. PubMed ID: 29675292
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Photoacoustic-based visual servoing of a needle tip.
    Lediju Bell MA; Shubert J
    Sci Rep; 2018 Oct; 8(1):15519. PubMed ID: 30341371
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Photoacoustic imaging in percutaneous radiofrequency ablation: device guidance and ablation visualization.
    Francis KJ; Manohar S
    Phys Med Biol; 2019 Sep; 64(18):184001. PubMed ID: 31357187
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Three-dimensional therapy needle applicator segmentation for ultrasound-guided focal liver ablation.
    Gillies DJ; Awad J; Rodgers JR; Edirisinghe C; Cool DW; Kakani N; Fenster A
    Med Phys; 2019 Jun; 46(6):2646-2658. PubMed ID: 30994191
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Handheld volumetric photoacoustic/ultrasound imaging using an internal scanning mechanism.
    Pang Z; Wang Y; Qin W; Qi W; Xi L
    Opt Lett; 2022 May; 47(10):2418-2421. PubMed ID: 35561365
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study.
    Wei CW; Nguyen TM; Xia J; Arnal B; Wong EY; Pelivanov IM; O'Donnell M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Feb; 62(2):319-28. PubMed ID: 25643081
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Multi-modality photoacoustic/ultrasound imaging based on a commercial ultrasound platform.
    Pang Z; Wang Y; Wang Y; Sun Z; Qi W; Xi L
    Opt Lett; 2021 Sep; 46(17):4382-4385. PubMed ID: 34470021
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Simulations and human cadaver head studies to identify optimal acoustic receiver locations for minimally invasive photoacoustic-guided neurosurgery.
    Graham MT; Huang J; Creighton FX; Lediju Bell MA
    Photoacoustics; 2020 Sep; 19():100183. PubMed ID: 32695578
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Reliable and accurate needle localization in curvilinear ultrasound images using signature-based analysis of ultrasound beamformed radio frequency signals.
    Daoud MI; Abu-Hani AF; Alazrai R
    Med Phys; 2020 Jun; 47(6):2356-2379. PubMed ID: 32160309
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Performance Characteristics of Photoacoustic Imaging Probes with Varying Frequencies and Light-delivery Schemes.
    Rich LJ; Chamberlain SR; Falcone DR; Bruce R; Heinmiller A; Xia J; Seshadri M
    Ultrason Imaging; 2019 Nov; 41(6):319-335. PubMed ID: 31570083
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intraoperative Needle Tip Tracking with an Integrated Fibre-Optic Ultrasound Sensor.
    Baker C; Xochicale M; Lin FY; Mathews S; Joubert F; Shakir DI; Miles R; Mosse CA; Zhao T; Liang W; Kunpalin Y; Dromey B; Mistry T; Sebire NJ; Zhang E; Ourselin S; Beard PC; David AL; Desjardins AE; Vercauteren T; Xia W
    Sensors (Basel); 2022 Nov; 22(23):. PubMed ID: 36501738
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Three-Dimensional Ultrasonic Needle Tip Tracking with a Fiber-Optic Ultrasound Receiver.
    Xia W; West SJ; Finlay MC; Pratt R; Mathews S; Mari JM; Ourselin S; David AL; Desjardins AE
    J Vis Exp; 2018 Aug; (138):. PubMed ID: 30199033
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Tomographic Ultrasound and LED-Based Photoacoustic System for Preclinical Imaging.
    Francis KJ; Booijink R; Bansal R; Steenbergen W
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32422995
    [TBL] [Abstract][Full Text] [Related]  

  • 40. All-optical scanhead for ultrasound and photoacoustic dual-modality imaging.
    Hsieh BY; Chen SL; Ling T; Guo LJ; Li PC
    Opt Express; 2012 Jan; 20(2):1588-96. PubMed ID: 22274501
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.