These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

552 related articles for article (PubMed ID: 29724553)

  • 1. Effect of metal opaquer on the final color of 3 ceramic crown types on 3 abutment configurations.
    Arif R; Yilmaz B; Mortazavi A; Ozcelik TB; Johnston WM
    J Prosthet Dent; 2018 Sep; 120(3):375-381. PubMed ID: 29724553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of implant abutment material on the color of different ceramic crown systems.
    Dede DÖ; Armağanci A; Ceylan G; Celik E; Cankaya S; Yilmaz B
    J Prosthet Dent; 2016 Nov; 116(5):764-769. PubMed ID: 27402418
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems.
    Martínez-Rus F; Ferreiroa A; Özcan M; Bartolomé JF; Pradíes G
    Int J Oral Maxillofac Implants; 2012; 27(6):1448-55. PubMed ID: 23189296
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of abutment tooth color, cement color, and ceramic thickness on the resulting optical color of a CAD/CAM glass-ceramic lithium disilicate-reinforced crown.
    Chaiyabutr Y; Kois JC; Lebeau D; Nunokawa G
    J Prosthet Dent; 2011 Feb; 105(2):83-90. PubMed ID: 21262405
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical performance of cement- and screw-retained all-ceramic single crowns on dental implants.
    Obermeier M; Ristow O; Erdelt K; Beuer F
    Clin Oral Investig; 2018 Mar; 22(2):981-991. PubMed ID: 28710653
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical stability of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns.
    Pitta J; Hicklin SP; Fehmer V; Boldt J; Gierthmuehlen PC; Sailer I
    Int J Oral Maxillofac Implants; 2019; 34(5):1091–1097. PubMed ID: 30934031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Failure Load of Monolithic Lithium Disilicate Implant-Supported Single Crowns Bonded to Ti-base Abutments versus to Customized Ceramic Abutments after Fatigue.
    Spitznagel FA; Bonfante EA; Vollmer F; Gierthmuehlen PC
    J Prosthodont; 2022 Feb; 31(2):136-146. PubMed ID: 33870577
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments.
    Stona D; Burnett LH; Mota EG; Spohr AM
    J Am Dent Assoc; 2015 Jul; 146(7):501-7. PubMed ID: 26113098
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging.
    Atsü SS; Aksan ME; Bulut AC
    Int J Oral Maxillofac Implants; 2019; 34(3):622–630. PubMed ID: 30716141
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of different abutment materials on the color of implant-supported restoration: A laboratory study.
    Wang T; Hu Y; Jia L; Ye L
    Am J Dent; 2024 Jun; 37(3):164-168. PubMed ID: 38899998
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks.
    Yilmaz B; Alshahrani FA; Kale E; Johnston WM
    J Prosthet Dent; 2018 Jul; 120(1):71-78. PubMed ID: 29426786
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Masking ability of implant abutment substrates by using different ceramic restorative systems.
    Soares PM; Cadore-Rodrigues AC; Packaeser MG; Bacchi A; Valandro LF; Pereira GKR; Rippe MP
    J Prosthet Dent; 2022 Sep; 128(3):496.e1-496.e8. PubMed ID: 35985853
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro color stainability and relative translucency of CAD-CAM restorative materials used for laminate veneers and complete crowns.
    Arif R; Yilmaz B; Johnston WM
    J Prosthet Dent; 2019 Aug; 122(2):160-166. PubMed ID: 30885587
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Marginal discrepancy of monolithic and veneered all-ceramic crowns on titanium and zirconia implant abutments before and after adhesive cementation: a scanning electron microscopy analysis.
    Martinez-Rus F; Ferreiroa A; Ozcan M; Pradies G
    Int J Oral Maxillofac Implants; 2013; 28(2):480-7. PubMed ID: 23527350
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of substrate, ceramic thickness, translucency, and cement shade on the color of CAD/CAM lithium-disilicate crowns.
    Czigola A; Abram E; Kovacs ZI; Marton K; Hermann P; Borbely J
    J Esthet Restor Dent; 2019 Sep; 31(5):457-464. PubMed ID: 30957412
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface.
    Hjerppe J; Jung RE; Hämmerle CH; Özcan M; Mühlemann S
    J Dent; 2022 Jun; 121():104121. PubMed ID: 35395344
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of framework material on the color of implant-supported complete-arch fixed dental prostheses.
    Yilmaz B; Alp G; Johnston WM
    J Prosthet Dent; 2019 Jul; 122(1):69-75. PubMed ID: 30910280
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of fracture resistance of pressable metal ceramic custom implant abutment with a commercially fabricated CAD/CAM zirconia implant abutment.
    Protopapadaki M; Monaco EA; Kim HI; Davis EL
    J Prosthet Dent; 2013 Nov; 110(5):389-96. PubMed ID: 24011801
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.
    Cooper LF; Stanford C; Feine J; McGuire M
    J Prosthet Dent; 2016 Jul; 116(1):33-9. PubMed ID: 26831919
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Retentive strength of implant-supported CAD-CAM lithium disilicate crowns on zirconia custom abutments using 6 different cements.
    Sellers K; Powers JM; Kiat-Amnuay S
    J Prosthet Dent; 2017 Feb; 117(2):247-252. PubMed ID: 27677215
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.