These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 2972559)

  • 21. A very low dead space pneumotachograph for ventilatory measurements in newborns.
    Vallinis P; Davis GM; Coates AL
    J Appl Physiol (1985); 1990 Oct; 69(4):1542-5. PubMed ID: 2262479
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [The impossibility of direct flow measurements in lung function studies. Analysis of errors and compensation].
    Brunner J; Langenstein H; Wolff G
    Schweiz Med Wochenschr; 1983 Aug; 113(33):1130-3. PubMed ID: 6226094
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Shunt effect of gas compression inside pneumotachographs during forced oscillations.
    Louis B; Harf A; Lorino H; Isabey D
    J Appl Physiol (1985); 1991 Jan; 70(1):143-51. PubMed ID: 2010369
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A new approach to laminar flowmeters.
    Pena FL; Diaz AD; Lema MR; Rodriguez SV
    Sensors (Basel); 2010; 10(12):10560-70. PubMed ID: 22163486
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Improved accuracy and extended flow range for a Fleisch pneumotachograph.
    Strömberg NO; Grönkvist MJ
    Med Biol Eng Comput; 1999 Jul; 37(4):456-60. PubMed ID: 10696702
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [A new generation of pulmonary function measuring system].
    Zeng BX; Chen SS; Huang M
    Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Feb; 24(2):86-8. PubMed ID: 12583095
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy, precision and linearity of the portable flow-volume meter Microspiro HI-298.
    Dompeling E; van Schayck CP; Folgering H; van den Hoogen HJ; van Weel C
    Eur Respir J; 1991 May; 4(5):612-5. PubMed ID: 1936232
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Nonlinear model for offline correction of pulmonary waveform generators.
    Reynolds JS; Stemple KJ; Petsko RA; Ebeling TR; Frazer DG
    IEEE Trans Biomed Eng; 2002 Dec; 49(12 Pt 2):1567-73. PubMed ID: 12549738
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A study of dynamic errors of measuring main respiratory parameters by devices fitted out with variable pressure differential flowmeters].
    Sivachev AV
    Med Tekh; 1991; (1):12-4. PubMed ID: 1828102
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of gas flowmeters determined by the bubble meter method.
    Waaben J; Stokke DB; Brinkløv MM
    Br J Anaesth; 1978 Dec; 50(12):1251-6. PubMed ID: 154917
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A fast, digitally controlled flow proportional gas injection system for studies in lung function.
    Kanhai JK; Caspers PJ; Reinders EG; Pompe JC; Bruining HA; Puppels GJ
    IEEE Trans Biomed Eng; 2003 Nov; 50(11):1268-75. PubMed ID: 14619997
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Evaluation of the performance of 2 mini-flow meters].
    Teculescu DB; Hannhart B; Malvestio P; Bahlaoui A; Sadoul P
    Rev Mal Respir; 1987; 4(3):121-5. PubMed ID: 2956648
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Linearity and frequency response of Fleisch type pneumotachometers.
    Zock JP
    Pflugers Arch; 1981 Oct; 391(4):345-52. PubMed ID: 7312571
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Simple low-cost construction and calibration of accurate pneumotachographs for monitoring mechanical ventilation in low-resource settings.
    Farré R; Rodríguez-Lázaro MA; Gozal D; Trias G; Solana G; Navajas D; Otero J
    Front Med (Lausanne); 2022; 9():938949. PubMed ID: 35979205
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Expiratory ventilation and carbon dioxide production measured with a thermistor flow-through system].
    Nagashima T
    Nihon Kyobu Shikkan Gakkai Zasshi; 1996 Mar; 34(3):281-9. PubMed ID: 8778467
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Avoid cruising on the uroflowmeter: evaluation of cruising artifact on spinning disc flowmeters in an experimental setup.
    Addla SK; Marri RR; Daayana SL; Irwin P
    Neurourol Urodyn; 2010 Sep; 29(7):1301-5. PubMed ID: 20879000
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Portable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.
    Pedersen OF; Miller MR; Sigsgaard T; Tidley M; Harding RM
    Eur Respir J; 1994 May; 7(5):991-7. PubMed ID: 8050558
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Numerically based design of an orifice plate flowmetering system for human respiratory flow monitoring.
    Fortuna AO; Gurd JR
    Ann Biomed Eng; 1999; 27(3):356-65. PubMed ID: 10374727
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Air flow rate converter errors depending on the manufacturing precision].
    Mironova NS
    Med Tekh; 1976; 0(3):17-9. PubMed ID: 1030770
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Evaluation of amplified spontaneous pattern ventilation in postoperative patients. Comparison with pressure support].
    Sánchez de Merás AM; Páiz P; Perpiñán I; García Polit J; Soliveres J; Aguilar G; Maruenda A; Belda FJ
    Rev Esp Anestesiol Reanim; 1999 May; 46(5):197-204. PubMed ID: 10379186
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.