These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 29729542)

  • 1. Safety and cost-effectiveness thrombolysis by diffusion-weighted imaging and fluid attenuated inversion recovery mismatch for wake-up stroke.
    Sun T; Xu Z; Diao SS; Zhang LL; Fang Q; Cai XY; Kong Y
    Clin Neurol Neurosurg; 2018 Jul; 170():47-52. PubMed ID: 29729542
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multicenter, randomized, double-blind, placebo-controlled trial to test efficacy and safety of magnetic resonance imaging-based thrombolysis in wake-up stroke (WAKE-UP).
    Thomalla G; Fiebach JB; Østergaard L; Pedraza S; Thijs V; Nighoghossian N; Roy P; Muir KW; Ebinger M; Cheng B; Galinovic I; Cho TH; Puig J; Boutitie F; Simonsen CZ; Endres M; Fiehler J; Gerloff C;
    Int J Stroke; 2014 Aug; 9(6):829-36. PubMed ID: 23490032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical characteristics of unknown symptom onset stroke patients with and without diffusion-weighted imaging and fluid-attenuated inversion recovery mismatch.
    Thomalla G; Boutitie F; Fiebach JB; Simonsen CZ; Pedraza S; Lemmens R; Nighoghossian N; Roy P; Muir KW; Ebinger M; Ford I; Cheng B; Galinovic I; Cho TH; Puig J; Thijs V; Endres M; Fiehler J; Gerloff C
    Int J Stroke; 2018 Jan; 13(1):66-73. PubMed ID: 28425349
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative Signal Intensity in Fluid-Attenuated Inversion Recovery and Treatment Effect in the WAKE-UP Trial.
    Cheng B; Boutitie F; Nickel A; Wouters A; Cho TH; Ebinger M; Endres M; Fiebach JB; Fiehler J; Galinovic I; Puig J; Thijs V; Lemmens R; Muir KW; Nighoghossian N; Pedraza S; Simonsen CZ; Gerloff C; Thomalla G;
    Stroke; 2020 Jan; 51(1):209-215. PubMed ID: 31662118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Are the current MRI criteria using the DWI-FLAIR mismatch concept for selection of patients with wake-up stroke to thrombolysis excluding too many patients?
    Odland A; Særvoll P; Advani R; Kurz MW; Kurz KD
    Scand J Trauma Resusc Emerg Med; 2015 Feb; 23():22. PubMed ID: 25888410
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Management of a wake-up stroke.
    Huang X; Alakbarzade V; Khandanpour N; Pereira AC
    Pract Neurol; 2019 Aug; 19(4):326-331. PubMed ID: 30872357
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [EU-funded treatment study: WAKE-UP: a randomized, placebo-controlled MRI-based trial of thrombolysis in wake-up stroke].
    Thomalla G; Ebinger M; Fiehler J; Fiebach JB; Endres M; Gerloff C
    Nervenarzt; 2012 Oct; 83(10):1241-51. PubMed ID: 23015193
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stroke With Unknown Time of Symptom Onset: Baseline Clinical and Magnetic Resonance Imaging Data of the First Thousand Patients in WAKE-UP (Efficacy and Safety of MRI-Based Thrombolysis in Wake-Up Stroke: A Randomized, Doubleblind, Placebo-Controlled Trial).
    Thomalla G; Boutitie F; Fiebach JB; Simonsen CZ; Nighoghossian N; Pedraza S; Lemmens R; Roy P; Muir KW; Ebinger M; Ford I; Cheng B; Galinovic I; Cho TH; Puig J; Thijs V; Endres M; Fiehler J; Gerloff C;
    Stroke; 2017 Mar; 48(3):770-773. PubMed ID: 28174327
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Should IV Thrombolysis be given in Patients with Suspected Ischemic Stroke but Unknown Symptom Onset and Without Diffusion-Weighted Imaging Lesion? - Results of a Case-Control Study.
    Seyhan M; Mackenrodt D; Gunreben I; Müllges W; Haeusler KG; Pham M; Kleinschnitz C; Kraft P
    J Stroke Cerebrovasc Dis; 2020 Feb; 29(2):104515. PubMed ID: 31786042
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can diffusion-weighted imaging-fluid-attenuated inversion recovery mismatch (positive diffusion-weighted imaging/negative fluid-attenuated inversion recovery) at 3 Tesla identify patients with stroke at <4.5 hours?
    Emeriau S; Serre I; Toubas O; Pombourcq F; Oppenheim C; Pierot L
    Stroke; 2013 Jun; 44(6):1647-51. PubMed ID: 23640823
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Different Mismatch Concepts for Magnetic Resonance Imaging-Guided Thrombolysis in Unknown Onset Stroke.
    Scheldeman L; Wouters A; Boutitie F; Dupont P; Christensen S; Cheng B; Ebinger M; Endres M; Fiebach JB; Gerloff C; Muir KW; Nighoghossian N; Pedraza S; Simonsen CZ; Thijs V; Thomalla G; Lemmens R;
    Ann Neurol; 2020 Jun; 87(6):931-938. PubMed ID: 32227638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Effects of DWI-Infarct Lesion Volume on DWI-FLAIR Mismatch: Is There a Need for Size Stratification?
    Payabvash S; Taleb S; Benson JC; Rykken JB; Oswood MC; McKinney AM; Hoffman B
    J Neuroimaging; 2017 Jul; 27(4):392-396. PubMed ID: 27878926
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diffusion-Weighted Imaging and Fluid-Attenuated Inversion Recovery Quantification to Predict Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch Status in Ischemic Stroke With Unknown Onset.
    Scheldeman L; Wouters A; Dupont P; Christensen S; Boutitie F; Cheng B; Ebinger M; Endres M; Fiebach JB; Gerloff C; Muir KW; Nighoghossian N; Pedraza S; Simonsen CZ; Thijs V; Thomalla G; Lemmens R
    Stroke; 2022 May; 53(5):1665-1673. PubMed ID: 35105179
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diffusion-weighted imaging-fluid attenuated inversion recovery mismatch in nocturnal stroke patients with unknown time of onset.
    Huisa BN; Liebeskind DS; Raman R; Hao Q; Meyer BC; Meyer DM; Hemmen TM;
    J Stroke Cerebrovasc Dis; 2013 Oct; 22(7):972-7. PubMed ID: 22325574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modified DWI-FLAIR mismatch guided thrombolysis in unknown onset stroke.
    Jakubicek S; Krebs S; Posekany A; Ferrari J; Szabo J; Siarnik P; Lang W; Sykora M
    J Thromb Thrombolysis; 2019 Feb; 47(2):167-173. PubMed ID: 30415393
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MRI based thrombolysis for FLAIR-negative stroke patients within 4.5-6h after symptom onset.
    Wei XE; Zhou J; Li WB; Zhao YW; Li MH; Li YH
    J Neurol Sci; 2017 Jan; 372():421-427. PubMed ID: 27839719
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Acute treatment of ischemic stroke : Current standards].
    Barow E; Thomalla G
    Nervenarzt; 2019 Oct; 90(10):979-986. PubMed ID: 31407046
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical-Radiological Parameters Improve the Prediction of the Thrombolysis Time Window by Both MRI Signal Intensities and DWI-FLAIR Mismatch.
    Madai VI; Wood CN; Galinovic I; Grittner U; Piper SK; Revankar GS; Martin SZ; Zaro-Weber O; Moeller-Hartmann W; von Samson-Himmelstjerna FC; Heiss WD; Ebinger M; Fiebach JB; Sobesky J
    Cerebrovasc Dis; 2016; 42(1-2):57-65. PubMed ID: 26986943
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lesion Age Imaging in Acute Stroke: Water Uptake in CT Versus DWI-FLAIR Mismatch.
    Broocks G; Leischner H; Hanning U; Flottmann F; Faizy TD; Schön G; Sporns P; Thomalla G; Kamalian S; Lev MH; Fiehler J; Kemmling A
    Ann Neurol; 2020 Dec; 88(6):1144-1152. PubMed ID: 32939824
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimating nocturnal stroke onset times by magnetic resonance imaging in the WAKE-UP trial.
    Cheng B; Pinnschmidt H; Königsberg A; Schlemm E; Boutitie F; Ebinger M; Endres M; Fiebach JB; Fiehler J; Galinovic I; Lemmens R; Muir KW; Pedraza S; Puig J; Simonsen CZ; Thijs V; Wouters A; Gerloff C; Thomalla G
    Int J Stroke; 2022 Mar; 17(3):323-330. PubMed ID: 34791943
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.