BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 29734110)

  • 1. Calixarene-doped PVC polymeric films as size-selective optical sensors: Monitoring of salicylate in real samples.
    Abdel-Haleem FM; El Nashar RM
    Spectrochim Acta A Mol Biomol Spectrosc; 2018 Aug; 201():98-104. PubMed ID: 29734110
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Highly selective thiocyanate optochemical sensor based on manganese(III)-salophen ionophore.
    Abdel-Haleem FM; Rizk MS
    Mater Sci Eng C Mater Biol Appl; 2017 Jun; 75():682-687. PubMed ID: 28415515
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.
    Kormalı Ertürün HE; Demirel Özel A; Sayın S; Yılmaz M; Kılıç E
    Talanta; 2015 Jan; 132():669-75. PubMed ID: 25476362
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative study of 2-hydroxy propyl beta cyclodextrin and calixarene as ionophores in potentiometric ion-selective electrodes for neostigmine bromide.
    El-Kosasy AM; Nebsen M; Abd El-Rahman MK; Salem MY; El-Bardicy MG
    Talanta; 2011 Aug; 85(2):913-8. PubMed ID: 21726718
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a highly sensitive and selective mercury optical sensor based on immobilization of bis(thiophenal)-4,4'-methylenedianiline on a PVC membrane.
    Firooz AR; Ensafi AA; Hoseini KS; Kazemifard N
    Mater Sci Eng C Mater Biol Appl; 2014 May; 38():73-8. PubMed ID: 24656354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel PVC-membrane optical sensor for highly sensitive and selective determination of UO2(2+) ion based on a recently synthesized benzo-substituted macrocyclic diamide and dibenzoylmethane.
    Shamsipur M; Zargoosh K; Mizani F; Eshghi H; Rostami F
    Spectrochim Acta A Mol Biomol Spectrosc; 2010 Sep; 77(1):319-23. PubMed ID: 20635469
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Potassium ion-selective optodes based on the calix[6]arene hexaester and application in human serum assay.
    Chan WH; Lee AW; Kwong DW; Tam WL; Wang KM
    Analyst; 1996 Apr; 121(4):531-4. PubMed ID: 8633794
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a specific and highly sensitive optical chemical sensor for determination of Hg(II) based on a new synthesized ionophore.
    Firooz AR; Ensafi AA; Karimi K; Sharghi H
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):4167-72. PubMed ID: 23910329
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a selective optical sensor for Cr(VI) monitoring in polluted waters.
    Güell R; Fontàs C; Salvadó V; Anticó E
    Anal Chim Acta; 2007 Jul; 594(2):162-8. PubMed ID: 17586110
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of a sensitive and selective copper optode based on β-ketoimine modified calix[4]arene derivative.
    Rouis A; Echabaane M; Sakly N; Bonnamour I; Ben Ouada H
    Mater Sci Eng C Mater Biol Appl; 2015 Jan; 46():125-31. PubMed ID: 25491968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Salicylate poly(vinyl chloride) membrane electrode based on (2-[(E)-2-(4-nitrophenyl) hydrazono]-1-phenyl-2-(2-quinolyl)-1-ethanone) Cu(II).
    Ardakani MM; Jalayer MS; Safari J; Sadeghi Z; Zare HR
    Anal Biochem; 2005 Jun; 341(2):259-66. PubMed ID: 15907871
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Potentiometric response and mechanism of anionic recognition of heterocalixarene-based ion selective electrodes.
    Shishkanova TV; Sýkora D; Sessler JL; Král V
    Anal Chim Acta; 2007 Mar; 587(2):247-53. PubMed ID: 17386780
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cyanostar: C-H Hydrogen Bonding Neutral Carrier Scaffold for Anion-Selective Sensors.
    Zahran EM; Fatila EM; Chen CH; Flood AH; Bachas LG
    Anal Chem; 2018 Feb; 90(3):1925-1933. PubMed ID: 29356501
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Potentiometric evaluation of calix[4]arene anion receptors in membrane electrodes: phosphate detection.
    Kivlehan F; Mace WJ; Moynihan HA; Arrigan DW
    Anal Chim Acta; 2007 Feb; 585(1):154-60. PubMed ID: 17386660
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phosphorated calix[6]arene derivatives as an ionophore for atropine-selective membrane electrodes.
    Zareh MM; Malinowska E
    J AOAC Int; 2007; 90(1):147-52. PubMed ID: 17373445
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Potentiometric polymeric membrane electrodes for mercury detection using calixarene ionophores.
    Tyagi S; Agarwal H; Ikram S
    Water Sci Technol; 2010; 61(3):693-704. PubMed ID: 20150706
    [TBL] [Abstract][Full Text] [Related]  

  • 17. PVC membrane sensor for potentiometric determination of iron (II) in some pharmaceutical formulations based on a new neutral ionophore.
    Abounassif MA; Al-Omar MA; Amr AG; Mostafa GA
    Drug Test Anal; 2011 Jun; 3(6):373-9. PubMed ID: 21698780
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Benzodipyrrole derivates as new ionophores for anion-selective electrodes: improving potentiometric selectivity towards divalent anions.
    Cuartero M; Ortuño JA; García MS; Sánchez G; Más-Montoya M; Curiel D
    Talanta; 2011 Sep; 85(4):1876-81. PubMed ID: 21872032
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Studies of aluminum (III) ion-selective optical sensor based on a chromogenic calix[4]arene derivative.
    Echabaane M; Rouis A; Bonnamour I; Ben Ouada H
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 Nov; 115():269-74. PubMed ID: 23845984
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bulk optode sensors for batch and flow-through determinations of lead ion in water samples.
    Bualom C; Ngeontae W; Nitiyanontakit S; Ngamukot P; Imyim A; Tuntulani T; Aeungmaitrepirom W
    Talanta; 2010 Jul; 82(2):660-7. PubMed ID: 20602951
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.