BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

329 related articles for article (PubMed ID: 29735339)

  • 1. Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation.
    Yorukoglu AC; Demirkan AF; Buker N
    Acta Orthop Traumatol Turc; 2018 Jul; 52(4):294-298. PubMed ID: 29735339
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fixation of extra-articular distal humeral fractures with a lateral approach and a locked plate: an alternative method.
    Parmaksızoğlu AS; Özkaya U; Bilgili F; Mutlu H; Çetin Ü
    Acta Orthop Traumatol Turc; 2016; 50(2):132-8. PubMed ID: 26969946
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: A retrospective study.
    Trikha V; Agrawal P; Das S; Gaba S; Kumar A
    J Orthop Surg (Hong Kong); 2017; 25(3):2309499017727948. PubMed ID: 28844197
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures.
    Sohn HS; Shin SJ
    Injury; 2019 Jul; 50(7):1300-1305. PubMed ID: 31178147
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Functional results of the parallel-plate technique for complex distal humerus fractures].
    Atalar AC; Demirhan M; Salduz A; Kiliçoğlu O; Seyahi A
    Acta Orthop Traumatol Turc; 2009; 43(1):21-7. PubMed ID: 19293612
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fractures of the distal humerus operated on using the Lambda® plate: report of 75 cases at 9.5 years follow-up.
    Saragaglia D; Rouchy RC; Mercier N
    Orthop Traumatol Surg Res; 2013 Oct; 99(6):707-12. PubMed ID: 24029585
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion.
    Kim SJ; Lee SH; Son H; Lee BG
    Int Orthop; 2016 Jul; 40(7):1489-94. PubMed ID: 26202018
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Triceps-reflecting anconeus pedicle approach with double precontoured locking plate fixation is efficient in the treatment of orthopaedic trauma association type C distal humerus fracture.
    Chou YC; Hsu YH; Yu YH; Wu CC
    Injury; 2016 Oct; 47(10):2240-2246. PubMed ID: 27424532
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surgical treatment of complex distal humeral fractures: functional outcome after internal fixation using precontoured anatomic plates.
    Theivendran K; Duggan PJ; Deshmukh SC
    J Shoulder Elbow Surg; 2010 Jun; 19(4):524-32. PubMed ID: 20036579
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.
    Zhao W; Qu W; Fu C; Jiang H; Liu S; Cheng C
    Int Orthop; 2017 Sep; 41(9):1757-1762. PubMed ID: 28577034
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Results of parallel plate fixation of comminuted intra-articular distal humeral fractures.
    Flinkkilä T; Toimela J; Sirniö K; Leppilahti J
    J Shoulder Elbow Surg; 2014 May; 23(5):701-7. PubMed ID: 24745319
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual plate fixation on distal third diaphyseal fracture of the humerus.
    Lee JK; Choi YS; Sim YS; Choi DS; Han SH
    Int Orthop; 2017 Aug; 41(8):1655-1661. PubMed ID: 27909754
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Innovative techniques for the osteosynthesis of distal humeral fractures.
    Corradi A; Talamonti T; Cabitza P; Bottiglieri G; Secondi F
    Injury; 2010 Nov; 41(11):1117-9. PubMed ID: 20934694
    [TBL] [Abstract][Full Text] [Related]  

  • 14. AO extra-articular distal humerus locking plate: extended spectrum of usage in intra-articular distal fractures with metaphyseal extension--our experience with 20 cases.
    Aggarwal S; Kumar V; Bhagwat KR; Behera P
    Eur J Orthop Surg Traumatol; 2014 May; 24(4):505-11. PubMed ID: 23563623
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical outcomes of dual 3.5-mm locking compression plate fixation for humeral shaft fractures: Comparison with single 4.5-mm locking compression plate fixation.
    Seo JB; Heo K; Yang JH; Yoo JS
    J Orthop Surg (Hong Kong); 2019; 27(2):2309499019839608. PubMed ID: 30955460
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Locking plates in distal humerus fractures: study of 43 patients.
    Gupta RK; Gupta V; Marak DR
    Chin J Traumatol; 2013; 16(4):207-11. PubMed ID: 23910671
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures.
    Malhan S; Thomas S; Srivastav S; Agarwal S; Mittal V; Nadkarni B; Gulati D
    J Orthop Surg (Hong Kong); 2012 Dec; 20(3):292-6. PubMed ID: 23255632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures.
    Shin SJ; Kwak JW; Sohn HS
    Int Orthop; 2022 Sep; 46(9):2119-2126. PubMed ID: 35575805
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Surgical treatment of humeral diaphyseal fractures].
    Smejkal K; Lochman P; Dědek T; Trlica J
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surgical treatment of extra-articular distal-third diaphyseal fractures of the humerus using a modified posterior approach and an extra-articular plate.
    Páramo-Díaz P; Arroyo-Hernández M; Rodríguez Vega V; Aroca-Peinado M; León-Baltasar JL; Caba-Doussoux P
    Rev Esp Cir Ortop Traumatol; 2017; 61(6):404-411. PubMed ID: 28890121
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.