BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 2973832)

  • 1. [Angioplasty of a coronary bifurcation: a kissing wire technic using a new-design catheter].
    Steffenino G; Orzan F; Presbitero P
    Cardiologia; 1988 Aug; 33(8):805-8. PubMed ID: 2973832
    [No Abstract]   [Full Text] [Related]  

  • 2. [New technic for guidable balloon dilatation of coronary vessel stenoses].
    Kaltenbach M
    Z Kardiol; 1984 Nov; 73(11):669-73. PubMed ID: 6240841
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Kissing balloon angioplasty of a circumflex artery bifurcation lesion. A new approach utilizing two balloon-on-wire probes and a single guiding catheter.
    van Leeuwen K; Blans W; Pijls NH; van der Werf T
    Chest; 1989 May; 95(5):1144-5. PubMed ID: 2523294
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Coronary bifurcation stenoses: the kissing balloon Probe technique via a single guiding catheter.
    Myler RK; McConahay DR; Stertzer SH; Johnson W; Cumberland DC; Boucher RA; Hidalgo B
    Cathet Cardiovasc Diagn; 1989 Apr; 16(4):267-78. PubMed ID: 2523247
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The kissing balloon in angioplasty of coronary stenosis involving the bifurcation of a major branch].
    Bravi A; Del Sordo M; Pierli C; Tuveri A
    G Ital Cardiol; 1988 Jan; 18(1):68-71. PubMed ID: 2968290
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous double balloon coronary angioplasty through a single guiding catheter for bifurcation lesions.
    Thomas ES; Williams DO
    Cathet Cardiovasc Diagn; 1988; 15(4):260-4. PubMed ID: 2976308
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Increased primary success rate in coronary angioplasty using a guide wire with attached balloon (microprobe)].
    Unterberg C; Wiegand V; Tebbe U; Kim PG; Kreuzer H
    Z Kardiol; 1988 Sep; 77(9):573-5. PubMed ID: 2973692
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Angioplasty at coronary bifurcations: single-guide, two-wire technique.
    Oesterle SN; McAuley BJ; Buchbinder M; Simpson JB
    Cathet Cardiovasc Diagn; 1986; 12(1):57-63. PubMed ID: 2937537
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Kissing balloon coronary angioplasty.
    Meier B
    Am J Cardiol; 1984 Oct; 54(7):918-20. PubMed ID: 6237573
    [No Abstract]   [Full Text] [Related]  

  • 10. Sequential dilatation of septal and left anterior descending artery: single guiding catheter and double guide wire technique.
    Piscione F; Beatt K; de Feyter PJ; Serruys PW
    Cathet Cardiovasc Diagn; 1987; 13(1):33-8. PubMed ID: 2949850
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous transluminal coronary angioplasty with an over-the-wire system.
    Levin DC; Ganz P; Friedman P; Abben R; Garnic JD; Boxt LM
    Radiology; 1985 May; 155(2):323-6. PubMed ID: 3157203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Opening of chronic coronary artery occlusions with a recanalization catheter].
    Sievert H; Köhler KP; Kober G; Kaltenbach M
    Dtsch Med Wochenschr; 1988 Nov; 113(44):1703-7. PubMed ID: 2972533
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Magnum Meier wires with Crag Fx wire catheter for total occlusive coronary arteries.
    Kitazume H; Kubo I; Iwama T
    Cathet Cardiovasc Diagn; 1997 Feb; 40(2):198-201. PubMed ID: 9047067
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simplified two-wire technique for bifurcation lesions during coronary angioplasty.
    Bowser MA; Lozner EC; Johnson LW
    Cathet Cardiovasc Diagn; 1989 Feb; 16(2):136-8. PubMed ID: 2521574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long wire technique--experience with 100 procedures.
    Kaltenbach M; Vallbracht C; Kober G
    Z Kardiol; 1987; 76 Suppl 6():53-7. PubMed ID: 2964148
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-wire technique: a unique approach to percutaneous transluminal coronary angioplasty of a trifurcation lesion.
    Hartzler GO
    Cathet Cardiovasc Diagn; 1987; 13(3):174-7. PubMed ID: 2954646
    [No Abstract]   [Full Text] [Related]  

  • 17. [Percutaneous transluminal coronary angioplasty. Initial experience with the steerable technic at the Hospital Bellvitge-Princeps d'Espanya ].
    Esplugas E; Cequier A; Jara F; Pallarés C; Castells E
    Rev Esp Cardiol; 1985; 38 Suppl 1():21-4. PubMed ID: 2930873
    [No Abstract]   [Full Text] [Related]  

  • 18. [Extraction of a broken intracoronary PTCA guide wire perforating the circumflex artery, using a Dotter retrieval catheter].
    Höfling B; Erdmann E
    Z Kardiol; 1984 Oct; 73(10):663-5. PubMed ID: 6240168
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Coronary artery angioplasty using the Grüntzig technic. Development of the methodology and initial results at the Hospital de la Santa Creu i Sant Pau].
    Augé JM; Crexells C; Oriol A; García J; Carreras F; Peraza C
    Rev Esp Cardiol; 1985; 38 Suppl 1():14-20. PubMed ID: 2930872
    [No Abstract]   [Full Text] [Related]  

  • 20. [An improved guide catheter for percutaneous transluminal coronary angioplasty].
    Harmjanz D; Werner PC
    Z Kardiol; 1989 Feb; 78(2):78-80. PubMed ID: 2524137
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.