These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

243 related articles for article (PubMed ID: 29738695)

  • 1. An approach to analytical validation and testing of body fluid assays for the automated clinical laboratory.
    Block DR; Ouverson LJ; Wittwer CA; Saenger AK; Baumann NA
    Clin Biochem; 2018 Aug; 58():44-52. PubMed ID: 29738695
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Body fluid matrix evaluation on a Roche cobas 8000 system.
    Owen WE; Thatcher ML; Crabtree KJ; Greer RW; Strathmann FG; Straseski JA; Genzen JR
    Clin Biochem; 2015 Sep; 48(13-14):911-4. PubMed ID: 26006756
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Filling in the gaps with non-standard body fluids.
    Lo SY; Saifee NH; Mason BO; Greene DN
    Pract Lab Med; 2016 Aug; 5():24-31. PubMed ID: 28856201
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Analytical validation of 13 biochemistry parameters (CEA, CA 19-9, amylase, lipase, sodium, potassium, chloride, creatinine, glucose, protein, albumin, LDH, triglycerides) in body fluids].
    Oris C; Landrieaux L; Brailova M; Roszyk L; Rozand I; Sapin V; Bouvier D; Colombier M
    Ann Biol Clin (Paris); 2020 Feb; 78(1):93-107. PubMed ID: 32108587
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Establishing hemolysis, icterus, and lipemia interference limits for body fluid chemistry analytes measured on the Roche cobas instrument.
    Block DR; Lasho MA; Donato LJ; Meeusen JW
    Am J Clin Pathol; 2024 May; ():. PubMed ID: 38709595
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of an adenosine deaminase (ADA) assay in serum, pleural, pericardial, peritoneal, and cerebrospinal fluids on the Roche cobas c501 analyzer.
    Allison TR; Hunsaker JJH; La'ulu SL; Genzen JR
    Clin Biochem; 2022; 109-110():57-63. PubMed ID: 36122696
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pretreatment of Body Fluid Specimens Using Hyaluronidase and Ultracentrifugation.
    La'ulu SL; Turner DR; Zupan E; Genzen JR
    Lab Med; 2021 Sep; 52(5):469-476. PubMed ID: 33560339
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Alpha-fetoprotein in pericardial, peritoneal, and pleural fluids: A body fluid matrix evaluation.
    Owen WE; Hunsaker JJH; Genzen JR
    Clin Biochem; 2018 Jun; 56():109-112. PubMed ID: 29684369
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance specifications of common chemistry analytes on the AU series of chemistry analyzers for miscellaneous body fluids.
    Lin MJ; Hoke C; Dlott R; Lorey TS; Greene DN
    Clin Chim Acta; 2013 Nov; 426():121-6. PubMed ID: 23981843
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Body fluid analysis: clinical utility and applicability of published studies to guide interpretation of today's laboratory testing in serous fluids.
    Block DR; Algeciras-Schimnich A
    Crit Rev Clin Lab Sci; 2013; 50(4-5):107-24. PubMed ID: 24156653
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.
    Worlock A; Blair D; Hunsicker M; Le-Nguyen T; Motta C; Nguyen C; Papachristou E; Pham J; Williams A; Vi M; Vinluan B; Hatzakis A
    Virol J; 2017 Apr; 14(1):66. PubMed ID: 28372576
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of pH on the Quantification of Common Chemistry Analytes in Body Fluid Specimens Using the Roche cobas Analyzer for Clinical Diagnostic Testing.
    Nandakumar V; Dolan CT; Baumann NA; Block DR
    Am J Clin Pathol; 2021 Oct; 156(5):722-727. PubMed ID: 34075393
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.
    Voskoboev NV; Cambern SJ; Hanley MM; Giesen CD; Schilling JJ; Jannetto PJ; Lieske JC; Block DR
    Clin Biochem; 2015 Nov; 48(16-17):1126-30. PubMed ID: 26093046
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Pre-analytical quality in fluid samples cytopathology: Results of a survey from the French Society of Clinical Cytology].
    Courtade-Saïdi M; Fleury Feith J;
    Ann Pathol; 2015 Oct; 35(5):378-86. PubMed ID: 26372499
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Data on interference indices in body fluid specimens submitted for clinical laboratory analysis.
    Eigsti RL; Krasowski MD; Vidholia A; Merrill AE
    Data Brief; 2020 Jun; 30():105408. PubMed ID: 32258276
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a third party enzymatic ammonia method for use on the Roche Cobas 6000 (c501) automated platform.
    Seiden-Long I; Schnabl K; Skoropadyk W; Lennon N; McKeage A
    Clin Biochem; 2014 Aug; 47(12):1116-20. PubMed ID: 24792455
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of an enzymatic assay to measure lactate in perchloric acid-precipitated cerebrospinal fluid.
    Lu J; Genzen JR; Grenache DG
    Clin Chim Acta; 2018 Aug; 483():142-144. PubMed ID: 29709451
    [TBL] [Abstract][Full Text] [Related]  

  • 18. From bedside to bench-practical considerations to avoid pre-analytical pitfalls and assess sample quality for high-resolution metabolomics and lipidomics analyses of body fluids.
    Lehmann R
    Anal Bioanal Chem; 2021 Sep; 413(22):5567-5585. PubMed ID: 34159398
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Review of interference indices in body fluid specimens submitted for clinical chemistry analyses.
    Eigsti RL; Krasowski MD; Vidholia A; Merrill AE
    Pract Lab Med; 2020 Mar; 19():e00155. PubMed ID: 32099890
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers.
    Nikolac Gabaj N; Miler M; Vrtarić A; Hemar M; Filipi P; Kocijančić M; Šupak Smolčić V; Ćelap I; Šimundić AM
    Clin Chem Lab Med; 2018 Apr; 56(5):776-788. PubMed ID: 29315074
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.