These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
285 related articles for article (PubMed ID: 29739248)
1. Cable plating with a single strut allograft in the treatment of periprosthetic fractures of the femur. Manara JR; Mathews JA; Sandhu HS Hip Int; 2019 Jan; 29(1):58-64. PubMed ID: 29739248 [TBL] [Abstract][Full Text] [Related]
2. High union rates of locking compression plating with cortical strut allograft for type B1 periprosthetic femoral fractures. Yeo I; Rhyu KH; Kim SM; Park YS; Lim SJ Int Orthop; 2016 Nov; 40(11):2365-2371. PubMed ID: 26759257 [TBL] [Abstract][Full Text] [Related]
3. Use of Locking Plate and Strut Onlay Allografts for Periprosthetic Fracture Around Well-Fixed Femoral Components. Kim YH; Mansukhani SA; Kim JS; Park JW J Arthroplasty; 2017 Jan; 32(1):166-170. PubMed ID: 27407037 [TBL] [Abstract][Full Text] [Related]
4. [Periprosthetic Femoral Fractures after Total Hip Replacement: Our Results and Treatment Complications]. Pavelka T; Salášek M; Weisová D Acta Chir Orthop Traumatol Cech; 2017; 84(1):52-58. PubMed ID: 28253947 [TBL] [Abstract][Full Text] [Related]
5. Surgical outcomes of dual-plate fixation for periprosthetic femur fractures around a stable hip arthroplasty stem. Kubik JF; Bornes TD; Gausden EB; Klinger CE; Wellman DS; Helfet DL Arch Orthop Trauma Surg; 2022 Dec; 142(12):3605-3611. PubMed ID: 34003368 [TBL] [Abstract][Full Text] [Related]
6. [Treatment of Vancouver type B1 periprosthetic femoral fracture with locked plate and xenogenic bony plate]. Chen Q; Chen W; Ding ZQ; Liu GJ; Gao JT; Liu Y Zhongguo Gu Shang; 2016 Aug; 29(8):734-737. PubMed ID: 29282933 [TBL] [Abstract][Full Text] [Related]
7. Reconstructed the bone stock after femoral bone loss in Vancouver B3 periprosthetic femoral fractures using cortical strut allograft and impacted cancellous allograft. Li D; Hu Q; Kang P; Yang J; Zhou Z; Shen B; Pei F Int Orthop; 2018 Dec; 42(12):2787-2795. PubMed ID: 29869013 [TBL] [Abstract][Full Text] [Related]
8. Uncemented extensive porous titanium-coated long femoral stem prostheses are effective in treatment of Vancouver type B2 periprosthetic femoral fractures: A retrospective mid- to long-term follow-up study. Wang Q; Li D; Kang P J Orthop Surg (Hong Kong); 2019; 27(2):2309499019857653. PubMed ID: 31232172 [TBL] [Abstract][Full Text] [Related]
9. Superior outcome of strut allograft-augmented plate fixation for the treatment of periprosthetic fractures around a stable femoral stem. Khashan M; Amar E; Drexler M; Chechik O; Cohen Z; Steinberg EL Injury; 2013 Nov; 44(11):1556-60. PubMed ID: 23755973 [TBL] [Abstract][Full Text] [Related]
10. Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate. Haddad FS; Duncan CP; Berry DJ; Lewallen DG; Gross AE; Chandler HP J Bone Joint Surg Am; 2002 Jun; 84(6):945-50. PubMed ID: 12063328 [TBL] [Abstract][Full Text] [Related]
11. Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty. Laurer HL; Wutzler S; Possner S; Geiger EV; El Saman A; Marzi I; Frank J Arch Orthop Trauma Surg; 2011 Jul; 131(7):983-9. PubMed ID: 21331551 [TBL] [Abstract][Full Text] [Related]
12. A systematic review of open reduction and internal fixation of periprosthetic femur fractures with or without allograft strut, cerclage, and locked plates. Moore RE; Baldwin K; Austin MS; Mehta S J Arthroplasty; 2014 May; 29(5):872-6. PubMed ID: 24650900 [TBL] [Abstract][Full Text] [Related]
13. Vancouver B2 periprosthetic femoral fractures: a comparative study of stem revision versus internal fixation with plate. Spina M; Scalvi A Eur J Orthop Surg Traumatol; 2018 Aug; 28(6):1133-1142. PubMed ID: 29564613 [TBL] [Abstract][Full Text] [Related]
14. [Limited open reduction and double plates internal fixation for treatment of Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty]. Zhang Y; Fan X; Liu Y; Shao J; Tang J; Liu S; Yang T; Zhang C Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1428-31. PubMed ID: 24640358 [TBL] [Abstract][Full Text] [Related]
15. Treatment of Periprosthetic Femoral Fractures after Total Hip Arthroplasty Vancouver Type B. Bulatović N; Kezunović M; Vučetić Č; Abdić N; Benčić I; Čengić T Acta Clin Croat; 2017 Sep; 56(3):536-543. PubMed ID: 29479920 [TBL] [Abstract][Full Text] [Related]
16. Minimally invasive fixation of type B and C interprosthetic femoral fractures. Ehlinger M; Czekaj J; Adam P; Brinkert D; Ducrot G; Bonnomet F Orthop Traumatol Surg Res; 2013 Sep; 99(5):563-9. PubMed ID: 23769162 [TBL] [Abstract][Full Text] [Related]
17. Treatment of periprosthetic femur fractures around a well-fixed hip arthroplasty implant: span the whole bone. Moloney GB; Westrick ER; Siska PA; Tarkin IS Arch Orthop Trauma Surg; 2014 Jan; 134(1):9-14. PubMed ID: 24253261 [TBL] [Abstract][Full Text] [Related]
18. Re-fractures after periprosthetic femoral fracture: A difficult to treat growing evidence. Randelli F; Pace F; Priano D; Giai Via A; Randelli P Injury; 2018 Nov; 49 Suppl 3():S43-S47. PubMed ID: 30415668 [TBL] [Abstract][Full Text] [Related]
19. Orthogonal plating of Vancouver B1 and C-type periprosthetic femur fracture nonunions. Birch CE; Blankstein M; Chlebeck JD; Bartlett Rd CS Hip Int; 2017 Nov; 27(6):578-583. PubMed ID: 28574123 [TBL] [Abstract][Full Text] [Related]
20. Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. Wood GC; Naudie DR; McAuley J; McCalden RW J Arthroplasty; 2011 Sep; 26(6):886-92. PubMed ID: 20817391 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]