These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

312 related articles for article (PubMed ID: 29739257)

  • 1. Obtuse triangle screw configuration for optimal internal fixation of femoral neck fracture: an anatomical analysis.
    Zhu Q; Shi B; Xu B; Yuan J
    Hip Int; 2019 Jan; 29(1):72-76. PubMed ID: 29739257
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative biomechanical performance of two configurations of screw constructs and types used to stabilize different sites of unstable Pauwels type II femoral neck fractures: A finite element analysis.
    Chantarapanich N; Jitprapaikulsarn S; Mahaisavariya B; Mahaisavariya C
    Med Eng Phys; 2022 Sep; 107():103856. PubMed ID: 36068038
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration.
    Yang JJ; Lin LC; Chao KH; Chuang SY; Wu CC; Yeh TT; Lian YT
    J Bone Joint Surg Am; 2013 Jan; 95(1):61-9. PubMed ID: 23283374
    [TBL] [Abstract][Full Text] [Related]  

  • 4. How to choose the suitable FNS specification in young patients with femoral neck fracture: A finite element analysis.
    Fan Z; Huang Y; Su H; Jiang T
    Injury; 2021 Aug; 52(8):2116-2125. PubMed ID: 34154816
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures.
    Ma J; Zhao Z; Zhi X; Wang H; Wang W
    BMC Musculoskelet Disord; 2022 Nov; 23(1):1030. PubMed ID: 36447275
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone.
    Hawks MA; Kim H; Strauss JE; Oliphant BW; Golden RD; Hsieh AH; Nascone JW; O'Toole RV
    Clin Biomech (Bristol, Avon); 2013 Oct; 28(8):886-91. PubMed ID: 24050951
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimal position and apex-subchondral bone distance of cannulated screws for internal fixation of femoral neck fracture: A radiological study.
    Zhu Z; Liao F
    J Orthop Res; 2023 Jul; 41(7):1546-1554. PubMed ID: 36495052
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Posterior fully threaded positioning screw prevents femoral neck collapse in Garden I or II femoral neck fractures.
    Shin KH; Hong SH; Han SB
    Injury; 2020 Apr; 51(4):1031-1037. PubMed ID: 32089281
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The oblique triangle configuration of three parallel screws for femoral neck fracture fixation using computer-aided design modules.
    Zhang RY; Li JT; Zhao JX; Zhao Z; Zhang LC; Yun C; Su XY; Tang PF
    Sci Rep; 2022 Jan; 12(1):325. PubMed ID: 35013408
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures.
    Zhang RY; Zhang WP; Yang GM; Wang DF; Su P; Zhang Y; Nie SB; Li J; Zhao Z; Li JT; Zhang LC; Tang PF
    Orthop Surg; 2024 Apr; 16(4):953-964. PubMed ID: 38389204
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis.
    Fan X; Zhou Y; Dai S; Lao K; Zhang Q; Yu T
    BMC Musculoskelet Disord; 2024 Jan; 25(1):83. PubMed ID: 38245678
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparison of femoral neck system and inverted triangle cannulated screws fixations in treatment of Pauwels typle
    Yang J; Zhou X; Li L; Xu L; Zhu W; Xu W; Xia R; Wang X; Wang G; Hua X; Xu X; Fang S
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Sep; 35(9):1111-1118. PubMed ID: 34523275
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures.
    Zhou XQ; Li ZQ; Xu RJ; She YS; Zhang XX; Chen GX; Yu X
    Orthop Surg; 2021 Aug; 13(6):1802-1809. PubMed ID: 34351048
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis.
    Zhang RY; Li JT; Zhao JX; Zhao Z; Zhang LC; Yun C; Su XY; Tang PF
    Injury; 2022 Feb; 53(2):353-361. PubMed ID: 34801246
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws.
    Stoffel K; Zderic I; Gras F; Sommer C; Eberli U; Mueller D; Oswald M; Gueorguiev B
    J Orthop Trauma; 2017 Mar; 31(3):131-137. PubMed ID: 27755333
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Finite element analysis of the effect of cannulated screw placement and drilling frequency on femoral neck fracture fixation.
    Mei J; Liu S; Jia G; Cui X; Jiang C; Ou Y
    Injury; 2014 Dec; 45(12):2045-50. PubMed ID: 25172530
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis.
    Li N; Cheng KY; Fan J; Li Y; Yang M; Zhu S; Jiang X
    Sci Rep; 2024 Jul; 14(1):15519. PubMed ID: 38969693
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures.
    Li J; Wang M; Zhou J; Zhang H; Li L
    Injury; 2020 Apr; 51(4):995-1003. PubMed ID: 32151421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture.
    Teng Y; Zhang Y; Guo C
    Medicine (Baltimore); 2022 Jul; 101(28):e29450. PubMed ID: 35839002
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study.
    Chung H; Kim Y; Kook I; Kwak JW; Hwang KT
    Clin Orthop Surg; 2024 Apr; 16(2):184-193. PubMed ID: 38562623
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.