These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
130 related articles for article (PubMed ID: 29740571)
1. Hands-On Defibrillation Skills of Pediatric Acute Care Providers During a Simulated Ventricular Fibrillation Cardiac Arrest Scenario. Bhalala US; Balakumar N; Zamora M; Appachi E Front Pediatr; 2018; 6():107. PubMed ID: 29740571 [No Abstract] [Full Text] [Related]
2. The impact of manual defibrillation technique on no-flow time during simulated cardiopulmonary resuscitation. Perkins GD; Davies RP; Soar J; Thickett DR Resuscitation; 2007 Apr; 73(1):109-14. PubMed ID: 17223245 [TBL] [Abstract][Full Text] [Related]
3. Defibrillator Design and Usability May Be Impeding Timely Defibrillation. Reeson M; Kyeremanteng K; D'Egidio G Jt Comm J Qual Patient Saf; 2018 Sep; 44(9):536-544. PubMed ID: 30166037 [TBL] [Abstract][Full Text] [Related]
4. Delays in defibrillation: influence of different monitoring techniques. Perkins GD; Roberts C; Gao F Br J Anaesth; 2002 Sep; 89(3):405-8. PubMed ID: 12402718 [TBL] [Abstract][Full Text] [Related]
5. Factors associated with delayed defibrillation in cardiopulmonary resuscitation: A prospective simulation study. Castan C; Münch A; Mahling M; Haffner L; Griewatz J; Hermann-Werner A; Riessen R; Reutershan J; Celebi N PLoS One; 2017; 12(6):e0178794. PubMed ID: 28594858 [TBL] [Abstract][Full Text] [Related]
6. Pediatric defibrillation doses often fail to terminate prolonged out-of-hospital ventricular fibrillation in children. Berg MD; Samson RA; Meyer RJ; Clark LL; Valenzuela TD; Berg RA Resuscitation; 2005 Oct; 67(1):63-7. PubMed ID: 16199288 [TBL] [Abstract][Full Text] [Related]
7. Shockable rhythms and defibrillation during in-hospital pediatric cardiac arrest. Rodríguez-Núñez A; López-Herce J; del Castillo J; Bellón JM; Resuscitation; 2014 Mar; 85(3):387-91. PubMed ID: 24291590 [TBL] [Abstract][Full Text] [Related]
8. Defibrillation. Lee F Singapore Med J; 2011 Aug; 52(8):544-7. PubMed ID: 21879210 [TBL] [Abstract][Full Text] [Related]
9. Barriers in the implementation of the Resuscitation Guidelines: European survey of defibrillation techniques. Krawczyk P; Kononowicz AA; Andres J Scand J Trauma Resusc Emerg Med; 2016 Mar; 24():28. PubMed ID: 26969512 [TBL] [Abstract][Full Text] [Related]
11. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697 [TBL] [Abstract][Full Text] [Related]
12. CPR Guidance by an Emergency Physician via Video Call: A Simulation Study. Lee DK; Park SM; Kim YJ; Lee CA; Jeong WJ; Kim GW; Shin DH; Lee YH Emerg Med Int; 2018; 2018():1480726. PubMed ID: 30627442 [TBL] [Abstract][Full Text] [Related]
13. Automated external defibrillation versus manual defibrillation for prolonged ventricular fibrillation: lethal delays of chest compressions before and after countershocks. Berg RA; Hilwig RW; Kern KB; Sanders AB; Xavier LC; Ewy GA Ann Emerg Med; 2003 Oct; 42(4):458-67. PubMed ID: 14520316 [TBL] [Abstract][Full Text] [Related]
14. A prospective evaluation of the 'C.O.A.C.H.E.D.' cognitive aid for emergency defibrillation. Coggins A; Nottingham C; Chin M; Warburton S; Han M; Murphy M; Sutherland J; Moore N Australas Emerg Care; 2018 Aug; 21(3):81-86. PubMed ID: 30998882 [TBL] [Abstract][Full Text] [Related]
15. Transthoracic incremental monophasic versus biphasic defibrillation by emergency responders (TIMBER): a randomized comparison of monophasic with biphasic waveform ascending energy defibrillation for the resuscitation of out-of-hospital cardiac arrest due to ventricular fibrillation. Kudenchuk PJ; Cobb LA; Copass MK; Olsufka M; Maynard C; Nichol G Circulation; 2006 Nov; 114(19):2010-8. PubMed ID: 17060379 [TBL] [Abstract][Full Text] [Related]
16. Comparison of defibrillation efficacy between two pads placements in a pediatric porcine model of cardiac arrest. Ristagno G; Yu T; Quan W; Freeman G; Li Y Resuscitation; 2012 Jun; 83(6):755-9. PubMed ID: 22198420 [TBL] [Abstract][Full Text] [Related]
18. A prospective, randomized evaluation of effect of ventricular fibrillation duration on defibrillation thresholds in humans. Bardy GH; Ivey TD; Allen M; Johnson G J Am Coll Cardiol; 1989 May; 13(6):1362-6. PubMed ID: 2703617 [TBL] [Abstract][Full Text] [Related]
19. Hands-on defibrillation and electrocardiogram artefact filtering technology increases chest compression fraction and decreases peri-shock pause duration in a simulation model of cardiac arrest. Fernando SM; Cheskes S; Howes D CJEM; 2016 Jul; 18(4):270-5. PubMed ID: 26608543 [TBL] [Abstract][Full Text] [Related]
20. Comparison of outcomes after use of biphasic or monophasic defibrillators among out-of-hospital cardiac arrest patients: a nationwide population-based observational study. Tanabe S; Yasunaga H; Ogawa T; Koike S; Akahane M; Horiguchi H; Hatanaka T; Yokota H; Imamura T Circ Cardiovasc Qual Outcomes; 2012 Sep; 5(5):689-96. PubMed ID: 22967787 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]