These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 29756057)

  • 1. Clinical application of limiting laryngeal mask airway cuff pressures utilizing inflating syringe intrinsic recoil.
    Corda DM; Robards CB; Rice MJ; Morey TE; Gravenstein N; Vasilopoulos T; Brull SJ
    Rom J Anaesth Intensive Care; 2018 Apr; 25(1):11-18. PubMed ID: 29756057
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure.
    Rice MJ; Gravenstein NL; Brull SJ; Morey TE; Gravenstein N
    J Clin Monit Comput; 2011 Dec; 25(6):405-10. PubMed ID: 22076616
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A randomised controlled trial of the effect of laryngeal mask airway manometry on postoperative sore throat in spontaneously breathing adult patients presenting for surgery at a university teaching hospital.
    Waruingi D; Mung'ayi V; Gisore E; Wanyonyi S
    Afr Health Sci; 2019 Mar; 19(1):1705-1715. PubMed ID: 31149001
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of Minimum Effective Cuff Inflating Volume for Laryngeal Mask Airway and its Impact on Postoperative Pharyngeal Complications.
    Li BB; Yan J; Zhou HG; Hao J; Liu AJ; Ma ZL
    Chin Med J (Engl); 2015 Oct; 128(19):2570-6. PubMed ID: 26415792
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females.
    Brimacombe J; Holyoake L; Keller C; Brimacombe N; Scully M; Barry J; Talbutt P; Sartain J; McMahon P
    Anesthesiology; 2000 Jul; 93(1):26-31. PubMed ID: 10861142
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Laryngeal mask airways--to inflate or to deflate after insertion?
    von Ungern-Sternberg BS; Erb TO; Chambers NA; Heaney M
    Paediatr Anaesth; 2009 Sep; 19(9):837-43. PubMed ID: 19691691
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events: a prospective, randomized trial.
    Seet E; Yousaf F; Gupta S; Subramanyam R; Wong DT; Chung F
    Anesthesiology; 2010 Mar; 112(3):652-7. PubMed ID: 20179502
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical evaluation of a novel LMA with a color-coded pressure gauge.
    Martin DP; Bhalla T; Thung A; Tobias JD
    Int J Pediatr Otorhinolaryngol; 2013 Jan; 77(1):76-8. PubMed ID: 23098746
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of cuff-pressure changes in LMA-Classic and the new Soft Seal laryngeal masks during nitrous oxide anaesthesia in spontaneous breathing patients.
    van Zundert AA; Fonck K; Al-Shaikh B; Mortier EP
    Eur J Anaesthesiol; 2004 Jul; 21(7):547-52. PubMed ID: 15318467
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does cuff pressure monitoring reduce postoperative pharyngolaryngeal adverse events after LMA-ProSeal insertion? A parallel group randomised trial.
    Vasanth Karthik R; Ranganathan P; Kulkarni AP; Sharma KS
    J Anesth; 2014 Oct; 28(5):662-7. PubMed ID: 24643810
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children.
    Wong JG; Heaney M; Chambers NA; Erb TO; von Ungern-Sternberg BS
    Paediatr Anaesth; 2009 May; 19(5):464-9. PubMed ID: 19281479
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Airway sealing pressures of the laryngeal mask airway in pediatric patients.
    Epstein RH; Ferouz F; Jenkins MA
    J Clin Anesth; 1996 Mar; 8(2):93-8. PubMed ID: 8695106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The laryngeal mask in infants and children: what is the cuff pressure?
    Schloss B; Rice J; Tobias JD
    Int J Pediatr Otorhinolaryngol; 2012 Feb; 76(2):284-6. PubMed ID: 22169436
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation and variation of cuff inflating volumes and pressures in different adult models of laryngeal mask: a prospective randomized trial.
    Ruananukun N; Watcharotayangul J; Jeeranukosol S; Komonhirun R
    BMC Anesthesiol; 2020 May; 20(1):108. PubMed ID: 32380954
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Emergence characteristics and postoperative laryngopharyngeal morbidity with the laryngeal mask airway: a comparison of high versus low initial cuff volume.
    Brimacombe J; Holyoake L; Keller C; Barry J; Mecklem D; Blinco A; Weidmann K
    Anaesthesia; 2000 Apr; 55(4):338-43. PubMed ID: 10781119
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the LMA-classic with the new disposable soft seal laryngeal mask in spontaneously breathing adult patients.
    Van Zundert AA; Fonck K; Al-Shaikh B; Mortier E
    Anesthesiology; 2003 Nov; 99(5):1066-71. PubMed ID: 14576541
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation.
    Hockings L; Heaney M; Chambers NA; Erb TO; von Ungern-Sternberg BS
    Paediatr Anaesth; 2010 Apr; 20(4):313-7. PubMed ID: 20470334
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laryngeal mask airway protector generates higher oropharyngeal leak pressures compared to the laryngeal mask airway supreme: A randomized clinical trial in the ambulatory surgery unit.
    Acx E; Van Caelenberg E; De Baerdemaeker L; Coppens M
    J Anaesthesiol Clin Pharmacol; 2021; 37(2):221-225. PubMed ID: 34349370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of laryngeal mask cuff pressure on postoperative sore throat incidence.
    Burgard G; Möllhoff T; Prien T
    J Clin Anesth; 1996 May; 8(3):198-201. PubMed ID: 8703453
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of 2 cuff inflation methods of laryngeal mask airway Classic for safe use without cuff manometer in adults.
    Kim MS; Lee JR; Shin YS; Chung JW; Lee KH; Ahn KR
    Am J Emerg Med; 2014 Mar; 32(3):237-42. PubMed ID: 24360025
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.