These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 29756456)

  • 21. Performance evaluation of the FDA-approved Determine™ HIV-1/2 Ag/Ab Combo assay using plasma and whole blood specimens.
    Masciotra S; Luo W; Westheimer E; Cohen SE; Gay CL; Hall L; Pan Y; Peters PJ; Owen SM
    J Clin Virol; 2017 Jun; 91():95-100. PubMed ID: 28372891
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of Determine Combo and other point-of-care HIV tests among Seattle MSM.
    Stekler JD; Ure G; O'Neal JD; Lane A; Swanson F; Maenza J; Stevens C; Coombs RW; Dragavon J; Swenson PD; Golden MR
    J Clin Virol; 2016 Mar; 76():8-13. PubMed ID: 26774543
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Role of line immunoassay in the diagnosis of early HIV infection: a diagnostic case].
    Soylar M; Altuğlu I; Sertöz R; Gökengin D
    Mikrobiyol Bul; 2013 Jul; 47(3):567-9. PubMed ID: 23971936
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Performance of the Alere Determine™ HIV-1/2 Ag/Ab Combo Rapid Test with specimens from HIV-1 seroconverters from the US and HIV-2 infected individuals from Ivory Coast.
    Masciotra S; Luo W; Youngpairoj AS; Kennedy MS; Wells S; Ambrose K; Sprinkle P; Owen SM
    J Clin Virol; 2013 Dec; 58 Suppl 1(Suppl 1):e54-8. PubMed ID: 23911678
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Analysis of False-Negative Human Immunodeficiency Virus Rapid Tests Performed on Oral Fluid in 3 International Clinical Research Studies.
    Curlin ME; Gvetadze R; Leelawiwat W; Martin M; Rose C; Niska RW; Segolodi TM; Choopanya K; Tongtoyai J; Holtz TH; Samandari T; McNicholl JM;
    Clin Infect Dis; 2017 Jun; 64(12):1663-1669. PubMed ID: 28369309
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.
    Lavoie S; Caswell D; Gill MJ; Kadkhoda K; Charlton CL; Levett PN; Hatchette T; Garceau R; Maregmen J; Mazzulli T; Needle R; Kadivar K; Kim J
    J Clin Virol; 2018 Jul; 104():23-28. PubMed ID: 29704735
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Use of fourth-generation rapid combined antigen and antibody diagnostic tests for the detection of acute HIV infection in a community centre for men who have sex with men, between 2016 and 2019.
    Saz J; Dalmau-Bueno A; Meulbroek M; Pujol F; Coll J; Herraiz-Tomey Á; Pérez F; Marazzi G; Taboada H; Culqui DR; Caylà JA;
    PLoS One; 2021; 16(7):e0255065. PubMed ID: 34314468
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Performance of Alere Determine HIV-1/2 Ag/Ab Combo rapid test for acute HIV infection: a case report.
    Lanzafame M; Zorzi A; Rigo F; Adami I; Del Bravo P; Tonolli E; Concia E; Azzini AM
    Infez Med; 2015 Mar; 23(1):48-50. PubMed ID: 25819051
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Diagnostic tests: Human immunodeficiency virus type 1, type 2 (HIV-1, HIV 2)].
    Fujii T
    Nihon Rinsho; 2005 Jul; 63 Suppl 7():434-7. PubMed ID: 16111295
    [No Abstract]   [Full Text] [Related]  

  • 30. Performance of an Alternative Laboratory-Based HIV Diagnostic Testing Algorithm Using HIV-1 RNA Viral Load.
    Pitasi MA; Patel SN; Wesolowski LG; Masciotra S; Luo W; Owen SM; Delaney KP
    Sex Transm Dis; 2020 May; 47(5S Suppl 1):S18-S25. PubMed ID: 31895304
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Acute infections, cost and time to reporting of HIV test results in three U.S. State Public Health Laboratories.
    Nasrullah M; Wesolowski LG; Ethridge SF; Cranston K; Pentella M; Myers RA; Rudrik JT; Hutchinson AB; Bennett SB; Werner BG
    J Infect; 2016 Aug; 73(2):164-72. PubMed ID: 27237366
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of supplemental testing with the Multispot HIV-1/HIV-2 Rapid Test and APTIMA HIV-1 RNA Qualitative Assay to resolve specimens with indeterminate or negative HIV-1 Western blots.
    Linley L; Ethridge SF; Oraka E; Owen SM; Wesolowski LG; Wroblewski K; Landgraf KM; Parker MM; Brinson M; Branson BM
    J Clin Virol; 2013 Dec; 58 Suppl 1():e108-12. PubMed ID: 24342469
    [TBL] [Abstract][Full Text] [Related]  

  • 33. ARCHITECT® HIV Ag/Ab Combo assay: correlation of HIV-1 p24 antigen sensitivity and RNA viral load using genetically diverse virus isolates.
    Brennan CA; Yamaguchi J; Vallari A; Swanson P; Hackett JR
    J Clin Virol; 2013 Jun; 57(2):169-72. PubMed ID: 23485348
    [TBL] [Abstract][Full Text] [Related]  

  • 34. BioRad BioPlex® HIV Ag-Ab assay: Incidence of false positivity in a low-prevalence population and its effects on the current HIV testing algorithm.
    Parker J; Carrasco AF; Chen J
    J Clin Virol; 2019 Jul; 116():1-3. PubMed ID: 30981082
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of a rapid and simple fourth-generation HIV screening assay for qualitative detection of HIV p24 antigen and/or antibodies to HIV-1 and HIV-2.
    Beelaert G; Fransen K
    J Virol Methods; 2010 Sep; 168(1-2):218-22. PubMed ID: 20561542
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Acute HIV infection (AHI) in a specialized clinical setting: case-finding, description of virological, epidemiological and clinical characteristics.
    Ammassari A; Abbate I; Orchi N; Pinnetti C; Rozera G; Libertone R; Pierro P; Martini F; Puro V; Girardi E; Antinori A; Capobianchi MR
    J Int AIDS Soc; 2014; 17(4 Suppl 3):19676. PubMed ID: 25397426
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Performance of an alternative laboratory-based algorithm for diagnosis of HIV infection utilizing a third generation immunoassay, a rapid HIV-1/HIV-2 differentiation test and a DNA or RNA-based nucleic acid amplification test in persons with established HIV-1 infection and blood donors.
    Wesolowski LG; Delaney KP; Hart C; Dawson C; Owen SM; Candal D; Meyer WA; Ethridge SF; Branson BM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S45-9. PubMed ID: 21995934
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinical performance of the Multispot HIV-1/HIV-2 rapid test to correctly differentiate HIV-2 from HIV-1 infection in screening algorithms using third and fourth generation assays and to identify cross reactivity with the HIV-1 Western Blot.
    Ramos EM; Harb S; Dragavon J; Coombs RW
    J Clin Virol; 2013 Dec; 58 Suppl 1(0 1):e104-7. PubMed ID: 24342468
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of Multispot EIA with Western blot for confirmatory serodiagnosis of HIV.
    Torian LV; Forgione LA; Punsalang AE; Pirillo RE; Oleszko WR
    J Clin Virol; 2011 Dec; 52 Suppl 1():S41-4. PubMed ID: 21995935
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Field evaluation of the Abbott ARCHITECT HIV Ag/Ab Combo immunoassay.
    Kfutwah A; Lemée V; Ngono HV; De Oliveira F; Njouom R; Plantier JC
    J Clin Virol; 2013 Dec; 58 Suppl 1():e70-5. PubMed ID: 24342480
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.