BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 29759443)

  • 21. Bioimpedance Alerts from Cardiovascular Implantable Electronic Devices: Observational Study of Diagnostic Relevance and Clinical Outcomes.
    Smeets CJ; Vranken J; Van der Auwera J; Verbrugge FH; Mullens W; Dupont M; Grieten L; De Cannière H; Lanssens D; Vandenberk T; Storms V; Thijs IM; Vandervoort PM
    J Med Internet Res; 2017 Nov; 19(11):e393. PubMed ID: 29170147
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Impact of Remote Monitoring on Long-Term Prognosis in Heart Failure Patients in a Real-World Cohort: Results From All-Comers COMMIT-HF Trial.
    Kurek A; Tajstra M; Gadula-Gacek E; Buchta P; Skrzypek M; Pyka L; Wasiak M; Swietlinska M; Hawranek M; Polonski L; Gasior M; Kosiuk J
    J Cardiovasc Electrophysiol; 2017 Apr; 28(4):425-431. PubMed ID: 28176442
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Remote monitoring of implantable cardioverter-defibrillators and resynchronization devices to improve patient outcomes: dead end or way ahead?
    Braunschweig F; Anker SD; Proff J; Varma N
    Europace; 2019 Jun; 21(6):846-855. PubMed ID: 30903152
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical Course of Dual-Chamber Implantable Cardioverter-Defibrillator Recipients followed by Cardiac Remote Monitoring: Insights from the LION Registry.
    Schwab JO; Nägele H; Oswald H; Klein G; Gunkel O; Lang A; Bauer WR; Korb P; Hauser T
    Biomed Res Int; 2018; 2018():3120480. PubMed ID: 30519574
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of Remote Monitoring on Clinical Outcomes.
    Varma N; Ricci RP
    J Cardiovasc Electrophysiol; 2015 Dec; 26(12):1388-95. PubMed ID: 26337400
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effectiveness and safety of remote monitoring of patients with an implantable loop recorder.
    Drak-Hernández Y; Toquero-Ramos J; Fernández JM; Pérez-Pereira E; Castro-Urda V; Fernández-Lozano I
    Rev Esp Cardiol (Engl Ed); 2013 Dec; 66(12):943-8. PubMed ID: 24774107
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Remote Monitoring of Patients with Implantable Devices-Telemonitoring and Chronic Diseases.
    Tsirintani M
    Stud Health Technol Inform; 2023 Jun; 305():460-463. PubMed ID: 37387065
    [TBL] [Abstract][Full Text] [Related]  

  • 28. INvestigation on Routine Follow-up in CONgestive HearT FAilure Patients with Remotely Monitored Implanted Cardioverter Defibrillators SysTems (InContact).
    Hansen C; Loges C; Seidl K; Eberhardt F; Tröster H; Petrov K; Grönefeld G; Bramlage P; Birkenhauer F; Weiss C
    BMC Cardiovasc Disord; 2018 Jun; 18(1):131. PubMed ID: 29954340
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.
    Jung W; Rillig A; Birkemeyer R; Miljak T; Meyerfeldt U
    J Interv Card Electrophysiol; 2008 Oct; 23(1):73-85. PubMed ID: 18821006
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population.
    Sacher F; Probst V; Bessouet M; Wright M; Maluski A; Abbey S; Bordachar P; Deplagne A; Ploux S; Lande G; Jaïs P; Hocini M; Haïssaguerre M; Le Marec H; Clémenty J
    Europace; 2009 Apr; 11(4):489-94. PubMed ID: 19218576
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Stroke incidence in patients with cardiac implantable electronic devices remotely controlled with automatic alerts of atrial fibrillation. A sub-analysis of the HomeGuide study.
    Ricci RP; Vaccari D; Morichelli L; Zanotto G; Calò L; D'Onofrio A; Curnis A; Pisanò EC; Nangah R; Brieda M; Calzolari V; Melissano D; Rovai N; Gargaro A
    Int J Cardiol; 2016 Sep; 219():251-6. PubMed ID: 27340918
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Impact of remote monitoring on reducing the burden of inappropriate shocks related to implantable cardioverter-defibrillator lead fractures: insights from a French single-centre registry.
    Souissi Z; Guédon-Moreau L; Boulé S; Kouakam C; Finat L; Marquié C; Brigadeau F; Wissocque L; Mouton S; Montaigne D; Klug D; Kacet S; Lacroix D
    Europace; 2016 Jun; 18(6):820-7. PubMed ID: 26498163
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of remote monitoring on clinical events and associated health care utilization: A nationwide assessment.
    Piccini JP; Mittal S; Snell J; Prillinger JB; Dalal N; Varma N
    Heart Rhythm; 2016 Dec; 13(12):2279-2286. PubMed ID: 27544748
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Implantable cardioverter defibrillators and devices for cardiac resynchronization therapy: what perspective for patients' apps combined with remote monitoring?
    Sgreccia D; Mauro E; Vitolo M; Manicardi M; Valenti AC; Imberti JF; Ziacchi M; Boriani G
    Expert Rev Med Devices; 2022 Feb; 19(2):155-160. PubMed ID: 35129023
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association.
    Mairesse GH; Braunschweig F; Klersy K; Cowie MR; Leyva F
    Europace; 2015 May; 17(5):814-8. PubMed ID: 25713012
    [TBL] [Abstract][Full Text] [Related]  

  • 36. REmote SUpervision to Decrease HospitaLization RaTe. Unified and integrated platform for data collected from devices manufactured by different companies: Design and rationale of the RESULT study.
    Tajstra M; Sokal A; Gwóźdź A; Wilczek M; Gacek A; Wojciechowski K; Gadula-Gacek E; Adamowicz-Czoch E; Chłosta-Niepiekło K; Milewski K; Rozentryt P; Kalarus Z; Gąsior M; Poloński L
    Ann Noninvasive Electrocardiol; 2017 Jul; 22(4):. PubMed ID: 28019051
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Is the last before-death alert remote monitoring transmission in patients with heart failure life-threatening?
    Dyrbuś M; Tajstra M; Kurek A; Pyka Ł; Gąsior M
    Kardiol Pol; 2022; 80(3):286-292. PubMed ID: 35040485
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: a substudy of the ECOST trial.
    Guédon-Moreau L; Kouakam C; Klug D; Marquié C; Brigadeau F; Boulé S; Blangy H; Lacroix D; Clémenty J; Sadoul N; Kacet S
    J Cardiovasc Electrophysiol; 2014 Jul; 25(7):763-70. PubMed ID: 24602062
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Improved survival in patients enrolled promptly into remote monitoring following cardiac implantable electronic device implantation.
    Mittal S; Piccini JP; Snell J; Prillinger JB; Dalal N; Varma N
    J Interv Card Electrophysiol; 2016 Aug; 46(2):129-36. PubMed ID: 26860839
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Canadian Cardiovascular Society/Canadian Heart Rhythm Society joint position statement on the use of remote monitoring for cardiovascular implantable electronic device follow-up.
    Yee R; Verma A; Beardsall M; Fraser J; Philippon F; Exner DV
    Can J Cardiol; 2013 Jun; 29(6):644-51. PubMed ID: 23465345
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.