These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 29759649)

  • 1. Using pattern recognition entropy to select mass chromatograms to prepare total ion current chromatograms from raw liquid chromatography-mass spectrometry data.
    Chatterjee S; Major GH; Paull B; Rodriguez ES; Kaykhaii M; Linford MR
    J Chromatogr A; 2018 Jul; 1558():21-28. PubMed ID: 29759649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimized time alignment algorithm for LC-MS data: correlation optimized warping using component detection algorithm-selected mass chromatograms.
    Christin C; Smilde AK; Hoefsloot HC; Suits F; Bischoff R; Horvatovich PL
    Anal Chem; 2008 Sep; 80(18):7012-21. PubMed ID: 18715018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Time alignment algorithms based on selected mass traces for complex LC-MS data.
    Christin C; Hoefsloot HC; Smilde AK; Suits F; Bischoff R; Horvatovich PL
    J Proteome Res; 2010 Mar; 9(3):1483-95. PubMed ID: 20070124
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improving liquid chromatography-tandem mass spectrometry determinations by modifying noise frequency spectrum between two consecutive wavelet-based low-pass filtering procedures.
    Chen HP; Liao HJ; Huang CM; Wang SC; Yu SN
    J Chromatogr A; 2010 Apr; 1217(17):2804-11. PubMed ID: 20227706
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ion trace detection algorithm to extract pure ion chromatograms to improve untargeted peak detection quality for liquid chromatography/time-of-flight mass spectrometry-based metabolomics data.
    Wang SY; Kuo CH; Tseng YJ
    Anal Chem; 2015 Mar; 87(5):3048-55. PubMed ID: 25622715
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Chromatographic Retention Assisted Deconvolution of Liquid Chromatography-Mass Spectrometry Chromatogram of Natural Products.
    Chang Q; Shao Y; Yang Y; Yu H; Wang R
    Anal Sci; 2019 Feb; 35(2):201-206. PubMed ID: 30318488
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improving signal-to-noise ratios of liquid chromatography-tandem mass spectrometry peaks using noise frequency spectrum modification between two consecutive matched-filtering procedures.
    Wang SC; Huang CM; Chiang SM
    J Chromatogr A; 2007 Aug; 1161(1-2):192-7. PubMed ID: 17588590
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An entropy-based method for noise reduction of liquid chromatography-mass spectrometry data.
    Li Y; Qu H; Cheng Y
    Anal Chim Acta; 2008 Mar; 612(1):19-22. PubMed ID: 18331853
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Concept for facilitating analyst-mediated interpretation of qualitative chromatographic-mass spectral data: an alternative to manual examination of extracted ion chromatograms.
    Borges CR
    Anal Chem; 2007 Jul; 79(13):4805-13. PubMed ID: 17542552
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quality evaluation of extracted ion chromatograms and chromatographic peaks in liquid chromatography/mass spectrometry-based metabolomics data.
    Zhang W; Zhao PX
    BMC Bioinformatics; 2014; 15 Suppl 11(Suppl 11):S5. PubMed ID: 25350128
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Strategies to avoid false negative findings in residue analysis using liquid chromatography coupled to time-of-flight mass spectrometry.
    Kaufmann A; Butcher P
    Rapid Commun Mass Spectrom; 2006; 20(23):3566-72. PubMed ID: 17091534
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Direct and unbiased information recovery from liquid chromatography-mass spectrometry raw data for phenotype-differentiating metabolites based on screening window coefficient of ion currents.
    Kokubun T; D'Costa L
    Anal Chem; 2013 Sep; 85(18):8684-91. PubMed ID: 24004415
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An objective comparison of pre-processing methods for enhancement of liquid chromatography-mass spectrometry data.
    Fredriksson M; Petersson P; Jörntén-Karlsson M; Axelsson BO; Bylund D
    J Chromatogr A; 2007 Nov; 1172(2):135-50. PubMed ID: 17959187
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chemometric analysis of complex hyphenated data. Improvements of the component detection algorithm.
    Windig W; Smith WF
    J Chromatogr A; 2007 Jul; 1158(1-2):251-7. PubMed ID: 17418223
    [TBL] [Abstract][Full Text] [Related]  

  • 15. LC-MSsim--a simulation software for liquid chromatography mass spectrometry data.
    Schulz-Trieglaff O; Pfeifer N; Gröpl C; Kohlbacher O; Reinert K
    BMC Bioinformatics; 2008 Oct; 9():423. PubMed ID: 18842122
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.
    Tai SS; Welch MJ
    Anal Chem; 2004 Feb; 76(4):1008-14. PubMed ID: 14961732
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative LC-MS of polymers: determining accurate molecular weight distributions by combined size exclusion chromatography and electrospray mass spectrometry with maximum entropy data processing.
    Gruendling T; Guilhaus M; Barner-Kowollik C
    Anal Chem; 2008 Sep; 80(18):6915-27. PubMed ID: 18690749
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational approach to structural identification of phospholipids using raw mass spectra from nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry.
    Lim S; Byeon SK; Lee JY; Moon MH
    J Mass Spectrom; 2012 Aug; 47(8):1004-14. PubMed ID: 22899509
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Two tools for applying chromatographic retention data to the mass-based identification of peptides during hydrogen/deuterium exchange experiments by nano-liquid chromatography/matrix-assisted laser desorption/ionization mass spectrometry.
    Gershon PD
    Rapid Commun Mass Spectrom; 2010 Dec; 24(23):3373-9. PubMed ID: 21072792
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Profiling of N-acyl-homoserine lactones by liquid chromatography coupled with electrospray ionization and a hybrid quadrupole linear ion-trap and Fourier-transform ion-cyclotron-resonance mass spectrometry (LC-ESI-LTQ-FTICR-MS).
    Cataldi TR; Bianco G; Abate S
    J Mass Spectrom; 2008 Jan; 43(1):82-96. PubMed ID: 17708516
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.