These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 29759879)

  • 1. Cryoballoon Isolation of the Superior Vena Cava.
    Gonna H; Domenichini G; Conti S; Gomes J; Raju H; Gallagher MM
    JACC Clin Electrophysiol; 2016 Aug; 2(4):529-531. PubMed ID: 29759879
    [No Abstract]   [Full Text] [Related]  

  • 2. Impact of Pulmonary Vein Isolation on Superior Vena Cava Potentials With a Second-Generation Cryoballoon.
    Ichihara N; Miyazaki S; Kuroi A; Hachiya H; Nakamura H; Taniguchi H; Araki M; Takagi T; Iwasawa J; Iesaka Y
    J Cardiovasc Electrophysiol; 2015 Dec; 26(12):1321-6. PubMed ID: 26283521
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Beware of superior vena cava isolation during cryoballoon ablation of the right superior pulmonary vein.
    Bergonti M; Heidbuchel H; Sarkozy A
    Heart Rhythm O2; 2022 Jun; 3(3):323-324. PubMed ID: 35734290
    [No Abstract]   [Full Text] [Related]  

  • 4. Transseptal puncture from the jugular vein and balloon cryoablation for atrial fibrillation in a patient with azygos continuation of an interrupted inferior vena cava.
    Baszko A; Kałmucki P; Dankowski R; Łanocha M; Siminiak T; Szyszka A
    Europace; 2015 Jul; 17(7):1153-6. PubMed ID: 25750216
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cryoballoon ablation of paroxysmal atrial fibrillation within the dilated coronary sinus in a case of persistent left superior vena cava.
    Schneider MA; Schade A; Koller ML; Schumacher B
    Europace; 2009 Oct; 11(10):1387-9. PubMed ID: 19648587
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Atrial fibrillation resulting from superior vena cava drivers addressed with cryoballoon ablation: Late reconnection at the site of phrenic nerve pacing catheter.
    Ng B; Ilsar R; McGuire MA; Singarayar S
    HeartRhythm Case Rep; 2019 Jan; 5(1):10-14. PubMed ID: 30693197
    [No Abstract]   [Full Text] [Related]  

  • 7. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation.
    Ghosh J; Martin A; Keech AC; Chan KH; Gomes S; Singarayar S; McGuire MA
    Heart Rhythm; 2013 Sep; 10(9):1311-7. PubMed ID: 23792110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the first- and second-generation balloon.
    Casado-Arroyo R; Chierchia GB; Conte G; Levinstein M; Sieira J; Rodriguez-Mañero M; di Giovanni G; Baltogiannis Y; Wauters K; de Asmundis C; Sarkozy A; Brugada P
    Heart Rhythm; 2013 Sep; 10(9):1318-24. PubMed ID: 23891574
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cryoballoon ablation of atrial fibrillation in a patient with partial anomalous pulmonary vein drainage in the superior vena cava.
    Rizzi S; Ströker E; El Housari M; Belsack D; Chierchia GB; de Asmundis C
    HeartRhythm Case Rep; 2022 Feb; 8(2):119-121. PubMed ID: 35242551
    [No Abstract]   [Full Text] [Related]  

  • 10. Pulmonary vein isolation combined with superior vena cava isolation for atrial fibrillation ablation: a prospective randomized study.
    Wang XH; Liu X; Sun YM; Shi HF; Zhou L; Gu JN
    Europace; 2008 May; 10(5):600-5. PubMed ID: 18442966
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrophysiologic characteristics and outcome of segmental ostial superior vena cava isolation in patients with paroxysmal atrial fibrillation initiated by superior vena cava ectopy: comparison with pulmonary vein isolation.
    Muto M; Yamada T; Murakami Y; Okada T; Okamoto M; Shimizu T; Toyama J; Yoshida Y; Tsuboi N; Ito T; Kondo T; Inden Y; Hirai M; Murohara T
    J Electrocardiol; 2007 Oct; 40(4):319-25. PubMed ID: 17276446
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous transhepatic approach for cryoballoon pulmonary vein isolation in a patient with persistent atrial fibrillation and interruption of the inferior vena cava.
    Orme GJ; Mendenhall C; Blair F; Wen Chen SY; Rhee E; Su W
    HeartRhythm Case Rep; 2018 Aug; 4(8):332-335. PubMed ID: 30112281
    [No Abstract]   [Full Text] [Related]  

  • 13. Remote-controlled magnetic pulmonary vein isolation combined with superior vena cava isolation for paroxysmal atrial fibrillation: a prospective randomized study.
    Da Costa A; Levallois M; Romeyer-Bouchard C; Bisch L; Gate-Martinet A; Isaaz K
    Arch Cardiovasc Dis; 2015 Mar; 108(3):163-71. PubMed ID: 25662699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation.
    Martins RP; Hamon D; Césari O; Behaghel A; Behar N; Sellal JM; Daubert JC; Mabo P; Pavin D
    Heart Rhythm; 2014 Mar; 11(3):386-93. PubMed ID: 24389575
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Collateral nervous damages after cryoballoon pulmonary vein isolation.
    Guiot A; Savouré A; Godin B; Anselme F
    J Cardiovasc Electrophysiol; 2012 Apr; 23(4):346-51. PubMed ID: 22081875
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study.
    Neumann T; Vogt J; Schumacher B; Dorszewski A; Kuniss M; Neuser H; Kurzidim K; Berkowitsch A; Koller M; Heintze J; Scholz U; Wetzel U; Schneider MA; Horstkotte D; Hamm CW; Pitschner HF
    J Am Coll Cardiol; 2008 Jul; 52(4):273-8. PubMed ID: 18634982
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation.
    Aryana A; Mugnai G; Singh SM; Pujara DK; de Asmundis C; Singh SK; Bowers MR; Brugada P; d'Avila A; O'Neill PG; Chierchia GB
    Heart Rhythm; 2016 Feb; 13(2):424-32. PubMed ID: 26520204
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Catheter ablation using the third-generation cryoballoon provides an enhanced ability to assess time to pulmonary vein isolation facilitating the ablation strategy: Short- and long-term results of a multicenter study.
    Aryana A; Kowalski M; O'Neill PG; Koo CH; Lim HW; Khan A; Hokanson RB; Bowers MR; Kenigsberg DN; Ellenbogen KA;
    Heart Rhythm; 2016 Dec; 13(12):2306-2313. PubMed ID: 27503480
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon.
    Takami M; Lehmann HI; Misiri J; Parker KD; Sarmiento RI; Johnson SB; Packer DL
    Circ Arrhythm Electrophysiol; 2015 Aug; 8(4):836-45. PubMed ID: 26082516
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Circumferential pulmonary vein ablation of atrial fibrillation via superior vena cava approach in a patient with interruption of the inferior vena cava.
    Kato H; Kubota S; Yamada Y; Kumamoto T; Takasawa Y; Takahashi N; Yamamoto M
    Europace; 2010 May; 12(5):746-8. PubMed ID: 20139120
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.