BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

341 related articles for article (PubMed ID: 29781099)

  • 1. Flow cytometric analysis of extracellular vesicle subsets in plasma: impact of swarm by particles of non-interest.
    Libregts SFWM; Arkesteijn GJA; Németh A; Nolte-'t Hoen ENM; Wauben MHM
    J Thromb Haemost; 2018 Jul; 16(7):1423-1436. PubMed ID: 29781099
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved Flow Cytometric Light Scatter Detection of Submicron-Sized Particles by Reduction of Optical Background Signals.
    Arkesteijn GJA; Lozano-Andrés E; Libregts SFWM; Wauben MHM
    Cytometry A; 2020 Jun; 97(6):610-619. PubMed ID: 32459071
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation.
    van der Pol E; Sturk A; van Leeuwen T; Nieuwland R; Coumans F;
    J Thromb Haemost; 2018 Jun; 16(6):1236-1245. PubMed ID: 29575716
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prerequisites for the analysis and sorting of extracellular vesicle subpopulations by high-resolution flow cytometry.
    Groot Kormelink T; Arkesteijn GJ; Nauwelaers FA; van den Engh G; Nolte-'t Hoen EN; Wauben MH
    Cytometry A; 2016 Feb; 89(2):135-47. PubMed ID: 25688721
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hollow organosilica beads as reference particles for optical detection of extracellular vesicles.
    Varga Z; van der Pol E; Pálmai M; Garcia-Diez R; Gollwitzer C; Krumrey M; Fraikin JL; Gasecka A; Hajji N; van Leeuwen TG; Nieuwland R
    J Thromb Haemost; 2018 Jun; ():. PubMed ID: 29877049
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Large Extracellular Vesicles Can be Characterised by Multiplex Labelling Using Imaging Flow Cytometry.
    Johnson SM; Banyard A; Smith C; Mironov A; McCabe MG
    Int J Mol Sci; 2020 Nov; 21(22):. PubMed ID: 33218198
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enumeration of extracellular vesicles by a new improved flow cytometric method is comparable to fluorescence mode nanoparticle tracking analysis.
    Pasalic L; Williams R; Siupa A; Campbell H; Henderson MJ; Chen VMY
    Nanomedicine; 2016 May; 12(4):977-986. PubMed ID: 26767510
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fluorescence triggering: A general strategy for enumerating and phenotyping extracellular vesicles by flow cytometry.
    Arraud N; Gounou C; Turpin D; Brisson AR
    Cytometry A; 2016 Feb; 89(2):184-95. PubMed ID: 25857288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physical association of low density lipoprotein particles and extracellular vesicles unveiled by single particle analysis.
    Lozano-Andrés E; Enciso-Martinez A; Gijsbers A; Ridolfi A; Van Niel G; Libregts SFWM; Pinheiro C; van Herwijnen MJC; Hendrix A; Brucale M; Valle F; Peters PJ; Otto C; Arkesteijn GJA; Wauben MHM
    J Extracell Vesicles; 2023 Nov; 12(11):e12376. PubMed ID: 37942918
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Protocol for Measuring Concentrations of Extracellular Vesicles in Human Blood Plasma with Flow Cytometry.
    Hajji N; Hau CM; Nieuwland R; van der Pol E
    Methods Mol Biol; 2022; 2504():55-75. PubMed ID: 35467279
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of Individual Extracellular Vesicles by Flow Cytometry.
    Nolan JP; Duggan E
    Methods Mol Biol; 2018; 1678():79-92. PubMed ID: 29071676
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of Generic Fluorescent Markers for Detection of Extracellular Vesicles by Flow Cytometry.
    de Rond L; van der Pol E; Hau CM; Varga Z; Sturk A; van Leeuwen TG; Nieuwland R; Coumans FAW
    Clin Chem; 2018 Apr; 64(4):680-689. PubMed ID: 29453194
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of technical and clinical utility of a bead-based flow cytometry platform for multiparametric phenotyping of CNS-derived extracellular vesicles.
    Brahmer A; Geiß C; Lygeraki A; Neuberger E; Tzaridis T; Nguyen TT; Luessi F; Régnier-Vigouroux A; Hartmann G; Simon P; Endres K; Bittner S; Reiners KS; Krämer-Albers EM
    Cell Commun Signal; 2023 Oct; 21(1):276. PubMed ID: 37803478
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Labeling Extracellular Vesicles for Nanoscale Flow Cytometry.
    Morales-Kastresana A; Telford B; Musich TA; McKinnon K; Clayborne C; Braig Z; Rosner A; Demberg T; Watson DC; Karpova TS; Freeman GJ; DeKruyff RH; Pavlakis GN; Terabe M; Robert-Guroff M; Berzofsky JA; Jones JC
    Sci Rep; 2017 May; 7(1):1878. PubMed ID: 28500324
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Deriving Extracellular Vesicle Size From Scatter Intensities Measured by Flow Cytometry.
    de Rond L; Coumans FAW; Nieuwland R; van Leeuwen TG; van der Pol E
    Curr Protoc Cytom; 2018 Oct; 86(1):e43. PubMed ID: 30168659
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow Cytometric Analysis of Extracellular Vesicles.
    Morales-Kastresana A; Jones JC
    Methods Mol Biol; 2017; 1545():215-225. PubMed ID: 27943218
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry.
    Simeone P; Celia C; Bologna G; Ercolino E; Pierdomenico L; Cilurzo F; Grande R; Diomede F; Vespa S; Canonico B; Guescini M; Stocchi V; Lotti LV; Guagnano MT; Stellin L; Papa S; Trubiani O; Marchisio M; Miscia S; Lanuti P
    Int J Mol Sci; 2020 Oct; 21(21):. PubMed ID: 33114229
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measuring Extracellular Vesicles by Conventional Flow Cytometry: Dream or Reality?
    Lucchetti D; Battaglia A; Ricciardi-Tenore C; Colella F; Perelli L; De Maria R; Scambia G; Sgambato A; Fattorossi A
    Int J Mol Sci; 2020 Aug; 21(17):. PubMed ID: 32872424
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of extracellular vesicle DNA at the single-vesicle level by nano-flow cytometry.
    Liu H; Tian Y; Xue C; Niu Q; Chen C; Yan X
    J Extracell Vesicles; 2022 Apr; 11(4):e12206. PubMed ID: 35373518
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative Analysis of Platelet-Derived Extracellular Vesicles Using Flow Cytometry and Nanoparticle Tracking Analysis.
    George SK; Lauková L; Weiss R; Semak V; Fendl B; Weiss VU; Steinberger S; Allmaier G; Tripisciano C; Weber V
    Int J Mol Sci; 2021 Apr; 22(8):. PubMed ID: 33917210
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.