BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 29781944)

  • 1. Early Comparative Outcomes of Carbon Fiber-Reinforced Polymer Plate in the Fixation of Distal Femur Fractures.
    Mitchell PM; Lee AK; Collinge CA; Ziran BH; Hartley KG; Jahangir AA
    J Orthop Trauma; 2018 Aug; 32(8):386-390. PubMed ID: 29781944
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation.
    Byun SE; Vintimilla DR; Bedeir YH; Dean CS; Parry JA; Hak DJ; Mauffrey C
    Eur J Orthop Surg Traumatol; 2020 Aug; 30(6):1103-1107. PubMed ID: 32356122
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical outcomes of proximal femoral fractures treated with a novel carbon fiber-reinforced polyetheretherketone intramedullary nail.
    Takashima K; Nakahara I; Uemura K; Hamada H; Ando W; Takao M; Sugano N
    Injury; 2020 Mar; 51(3):678-682. PubMed ID: 31959356
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate.
    Schliemann B; Hartensuer R; Koch T; Theisen C; Raschke MJ; Kösters C; Weimann A
    J Shoulder Elbow Surg; 2015 Aug; 24(8):1282-8. PubMed ID: 25704209
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.
    Hak DJ; Fader R; Baldini T; Chadayammuri VBS
    Int Orthop; 2017 Sep; 41(9):1735-1739. PubMed ID: 28707049
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes.
    Padolino A; Porcellini G; Guollo B; Fabbri E; Kiran Kumar GN; Paladini P; Merolla G
    Musculoskelet Surg; 2018 Oct; 102(Suppl 1):49-56. PubMed ID: 30343471
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.
    Mugnai R; Tarallo L; Capra F; Catani F
    Orthop Traumatol Surg Res; 2018 Oct; 104(6):877-882. PubMed ID: 29807189
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today.
    Chloros GD; Prodromidis AD; Wilson J; Giannoudis PV
    Eur J Trauma Emerg Surg; 2022 Jun; 48(3):2387-2406. PubMed ID: 34487201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
    Perugia D; Guzzini M; Mazza D; Iorio C; Civitenga C; Ferretti A
    Injury; 2017 Oct; 48 Suppl 3():S24-S29. PubMed ID: 29025605
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.
    de Jong JJ; Lataster A; van Rietbergen B; Arts JJ; Geusens PP; van den Bergh JP; Willems PC
    BMC Med Imaging; 2017 Feb; 17(1):18. PubMed ID: 28241752
    [TBL] [Abstract][Full Text] [Related]  

  • 11. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up.
    Di Maggio B; Sessa P; Mantelli P; Maniscalco P; Rivera F; Calori GM; Bisogno L; Scaravilli G; Caforio M
    Injury; 2017 Oct; 48 Suppl 3():S34-S38. PubMed ID: 29025607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Carbon/PEEK nails: a case-control study of 22 cases.
    Sacchetti F; Andreani L; Palazzuolo M; Cherix S; Bonicoli E; Neri E; Capanna R
    Eur J Orthop Surg Traumatol; 2020 May; 30(4):643-651. PubMed ID: 31865455
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
    Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
    J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?
    Kutzler M; Patterson JT; Anz H; Siahaan J; Warner SJ; Gary JL
    Eur J Orthop Surg Traumatol; 2024 May; 34(4):2147-2153. PubMed ID: 38564013
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up.
    Guzzini M; Lanzetti RM; Lupariello D; Morelli F; Princi G; Perugia D; Ferretti A
    Injury; 2017 Jun; 48(6):1249-1252. PubMed ID: 28366469
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate.
    Rotini R; Cavaciocchi M; Fabbri D; Bettelli G; Catani F; Campochiaro G; Fontana M; Colozza A; De Biase CF; Ziveri G; Zapparoli C; Stacca F; Lupo R; Rapisarda S; Guerra E
    Musculoskelet Surg; 2015 Sep; 99 Suppl 1():S1-8. PubMed ID: 25962808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment of Distal Femur Nonunion Following Initial Fixation with a Lateral Locking Plate.
    Ebraheim NA; Buchanan GS; Liu X; Cooper ME; Peters N; Hessey JA; Liu J
    Orthop Surg; 2016 Aug; 8(3):323-30. PubMed ID: 27627715
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes of distal femoral fractures treated with minimally invasive plate osteosynthesis versus open reduction internal fixation with combined locking plate and interfragmentary screws.
    Wang SH; Wu CC; Li WT; Shen HC; Lin LC; Pan RY
    Int J Surg; 2019 May; 65():107-112. PubMed ID: 30951872
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patient perspective on the use of carbon fibre plates for extremity fracture fixation.
    Giannoudis VP; Rodham P; Antypas A; Mofori N; Chloros G; Giannoudis PV
    Eur J Orthop Surg Traumatol; 2023 Aug; 33(6):2573-2577. PubMed ID: 36656438
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system.
    Kimmeyer M; Schmalzl J; Rentschler V; Jessen M; Gerhardt C; Lehmann LJ
    BMC Musculoskelet Disord; 2023 Jan; 24(1):63. PubMed ID: 36694169
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.