205 related articles for article (PubMed ID: 29786862)
1. Experimental fluence-modulated proton computed tomography by pencil beam scanning.
Dedes G; Johnson RP; Pankuch M; Detrich N; Pols WMA; Rit S; Schulte RW; Parodi K; Landry G
Med Phys; 2018 Jul; 45(7):3287-3296. PubMed ID: 29786862
[TBL] [Abstract][Full Text] [Related]
2. Application of fluence field modulation to proton computed tomography for proton therapy imaging.
Dedes G; De Angelis L; Rit S; Hansen D; Belka C; Bashkirov V; Johnson RP; Coutrakon G; Schubert KE; Schulte RW; Parodi K; Landry G
Phys Med Biol; 2017 Jul; 62(15):6026-6043. PubMed ID: 28582265
[TBL] [Abstract][Full Text] [Related]
3. Experimental realization of dynamic fluence field optimization for proton computed tomography.
Dickmann J; Sarosiek C; Rykalin V; Pankuch M; Rit S; Detrich N; Coutrakon G; Johnson RP; Schulte RW; Parodi K; Landry G; Dedes G
Phys Med Biol; 2020 Sep; 65(19):195001. PubMed ID: 32575084
[TBL] [Abstract][Full Text] [Related]
4. An optimization algorithm for dose reduction with fluence-modulated proton CT.
Dickmann J; Rit S; Pankuch M; Johnson RP; Schulte RW; Parodi K; Dedes G; Landry G
Med Phys; 2020 Apr; 47(4):1895-1906. PubMed ID: 32040212
[TBL] [Abstract][Full Text] [Related]
5. Fluence-modulated proton CT optimized with patient-specific dose and variance objectives for proton dose calculation.
Dickmann J; Kamp F; Hillbrand M; Corradini S; Belka C; Schulte RW; Parodi K; Dedes G; Landry G
Phys Med Biol; 2021 Mar; 66(6):064001. PubMed ID: 33545701
[TBL] [Abstract][Full Text] [Related]
6. Prediction of image noise contributions in proton computed tomography and comparison to measurements.
Dickmann J; Wesp P; Rädler M; Rit S; Pankuch M; Johnson RP; Bashkirov V; Schulte RW; Parodi K; Landry G; Dedes G
Phys Med Biol; 2019 Jul; 64(14):145016. PubMed ID: 31125986
[TBL] [Abstract][Full Text] [Related]
7. The effect of beam purity and scanner complexity on proton CT accuracy.
Piersimoni P; Ramos-Méndez J; Geoghegan T; Bashkirov VA; Schulte RW; Faddegon BA
Med Phys; 2017 Jan; 44(1):284-298. PubMed ID: 28066887
[TBL] [Abstract][Full Text] [Related]
8. Two-dimensional noise reconstruction in proton computed tomography using distance-driven filtered back-projection of simulated projections.
Rädler M; Landry G; Rit S; Schulte RW; Parodi K; Dedes G
Phys Med Biol; 2018 Oct; 63(21):215009. PubMed ID: 30277469
[TBL] [Abstract][Full Text] [Related]
9. Helium CT: Monte Carlo simulation results for an ideal source and detector with comparison to proton CT.
Piersimoni P; Faddegon BA; Méndez JR; Schulte RW; Volz L; Seco J
Med Phys; 2018 Jul; 45(7):3264-3274. PubMed ID: 29727481
[TBL] [Abstract][Full Text] [Related]
10. A reconstruction approach for proton computed tomography by modeling the integral depth dose of the scanning proton pencil beam.
Chen X; Medrano M; Sun B; Hao Y; Reynoso FJ; Darafsheh A; Yang D; Zhang T; Zhao T
Med Phys; 2022 Apr; 49(4):2602-2620. PubMed ID: 35103331
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the impact of a scanner prototype on proton CT and helium CT image quality and dose efficiency with Monte Carlo simulation.
Götz S; Dickmann J; Rit S; Krah N; Khellaf F; Schulte RW; Parodi K; Dedes G; Landry G
Phys Med Biol; 2022 Feb; 67(5):. PubMed ID: 35086073
[No Abstract] [Full Text] [Related]
12. A pencil beam approach to proton computed tomography.
Rescigno R; Bopp C; Rousseau M; Brasse D
Med Phys; 2015 Nov; 42(11):6610-24. PubMed ID: 26520752
[TBL] [Abstract][Full Text] [Related]
13. Software platform for simulation of a prototype proton CT scanner.
Giacometti V; Bashkirov VA; Piersimoni P; Guatelli S; Plautz TE; Sadrozinski HF; Johnson RP; Zatserklyaniy A; Tessonnier T; Parodi K; Rosenfeld AB; Schulte RW
Med Phys; 2017 Mar; 44(3):1002-1016. PubMed ID: 28094862
[TBL] [Abstract][Full Text] [Related]
14. Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy.
Dedes G; Dickmann J; Niepel K; Wesp P; Johnson RP; Pankuch M; Bashkirov V; Rit S; Volz L; Schulte RW; Landry G; Parodi K
Phys Med Biol; 2019 Aug; 64(16):165002. PubMed ID: 31220814
[TBL] [Abstract][Full Text] [Related]
15. Proton radiography and proton computed tomography based on time-resolved dose measurements.
Testa M; Verburg JM; Rose M; Min CH; Tang S; Bentefour EH; Paganetti H; Lu HM
Phys Med Biol; 2013 Nov; 58(22):8215-33. PubMed ID: 24200989
[TBL] [Abstract][Full Text] [Related]
16. Comparative accuracy and resolution assessment of two prototype proton computed tomography scanners.
Dedes G; Drosten H; Götz S; Dickmann J; Sarosiek C; Pankuch M; Krah N; Rit S; Bashkirov V; Schulte RW; Johnson RP; Parodi K; DeJongh E; Landry G
Med Phys; 2022 Jul; 49(7):4671-4681. PubMed ID: 35396739
[TBL] [Abstract][Full Text] [Related]
17. Feasibility of energy-resolved dose imaging technique in pencil beam scanning mode.
Alaka BG; Bentefour EH; Chirvase C; Samuel D; Teo BK
Biomed Phys Eng Express; 2020 Sep; 6(6):. PubMed ID: 35102004
[No Abstract] [Full Text] [Related]
18. A novel design of proton computed tomography detected by multiple-layer ionization chamber with strip chambers: A feasibility study with Monte Carlo simulation.
Chen X; Liu R; Zhou S; Sun B; Reynoso FJ; Mutic S; Zhang T; Zhao T
Med Phys; 2020 Feb; 47(2):614-625. PubMed ID: 31705662
[TBL] [Abstract][Full Text] [Related]
19. Photon scatter in portal images: accuracy of a fluence based pencil beam superposition algorithm.
McCurdy BM; Pistorius S
Med Phys; 2000 May; 27(5):913-22. PubMed ID: 10841394
[TBL] [Abstract][Full Text] [Related]
20. Quantifying the effect of air gap, depth, and range shifter thickness on TPS dosimetric accuracy in superficial PBS proton therapy.
Shirey RJ; Wu HT
J Appl Clin Med Phys; 2018 Jan; 19(1):164-173. PubMed ID: 29239528
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]