These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 29787413)

  • 1. Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model.
    Bomberg H; Meiser F; Daume P; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A
    Anesth Analg; 2019 Aug; 129(2):371-379. PubMed ID: 29787413
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Volumetric and reflective device dead space of anaesthetic reflectors under different conditions.
    Bomberg H; Veddeler M; Volk T; Groesdonk HV; Meiser A
    J Clin Monit Comput; 2018 Dec; 32(6):1073-1080. PubMed ID: 29374847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Apparent dead space with the anesthetic conserving device, AnaConDa®: a clinical and laboratory investigation.
    Sturesson LW; Bodelsson M; Johansson A; Jonson B; Malmkvist G
    Anesth Analg; 2013 Dec; 117(6):1319-24. PubMed ID: 24257381
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Halving the volume of AnaConDa: initial clinical experience with a new small-volume anaesthetic reflector in critically ill patients-a quality improvement project.
    Bomberg H; Meiser F; Zimmer S; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A
    J Clin Monit Comput; 2018 Aug; 32(4):639-646. PubMed ID: 29700664
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation.
    Sturesson LW; Bodelsson M; Jonson B; Malmkvist G
    Br J Anaesth; 2014 Sep; 113(3):508-14. PubMed ID: 24871871
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice.
    Marcos-Vidal JM; Merino M; González R; García C; Rey S; Pérez I
    J Clin Monit Comput; 2020 Feb; 34(1):89-95. PubMed ID: 30784010
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reflection efficiencies of AnaConDa-S and AnaConDa-100 for isoflurane under dry laboratory and simulated clinical conditions: a bench study using a test lung.
    Kermad A; Speltz J; Daume P; Volk T; Meiser A
    Expert Rev Med Devices; 2021 Feb; 18(2):189-195. PubMed ID: 33322972
    [No Abstract]   [Full Text] [Related]  

  • 8. Carbon dioxide rebreathing with the anaesthetic conserving device, AnaConDa®.
    Sturesson LW; Malmkvist G; Bodelsson M; Niklason L; Jonson B
    Br J Anaesth; 2012 Aug; 109(2):279-83. PubMed ID: 22505637
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increasing the reflection efficiency of the Sedaconda ACD-S by heating and cooling the anaesthetic reflector: a bench study using a test lung.
    Meiser A; Meis PLF; O'Gara B; Volk T; Kermad A
    J Clin Monit Comput; 2023 Jun; 37(3):919-924. PubMed ID: 36625981
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care.
    Farrell R; Oomen G; Carey P
    J Clin Monit Comput; 2018 Aug; 32(4):595-604. PubMed ID: 29388094
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Technical performance and reflection capacity of the anaesthetic conserving device--a bench study with isoflurane and sevoflurane.
    Meiser A; Bellgardt M; Belda J; Röhm K; Laubenthal H; Sirtl C
    J Clin Monit Comput; 2009 Feb; 23(1):11-9. PubMed ID: 19189222
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ventilatory Effects of Isoflurane Sedation via the Sedaconda ACD-S versus ACD-L: A Substudy of a Randomized Trial.
    Müller-Wirtz LM; Becher T; Günther U; Bellgardt M; Sackey P; Volk T; Meiser A
    J Clin Med; 2023 May; 12(9):. PubMed ID: 37176754
    [TBL] [Abstract][Full Text] [Related]  

  • 14. AnaConDa reflection filter: bench and patient evaluation of safety and volatile anesthetic conservation.
    Berton J; Sargentini C; Nguyen JL; Belii A; Beydon L
    Anesth Analg; 2007 Jan; 104(1):130-4. PubMed ID: 17179257
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation.
    Le Bourdellès G; Mier L; Fiquet B; Djedaïni K; Saumon G; Coste F; Dreyfuss D
    Chest; 1996 Nov; 110(5):1294-8. PubMed ID: 8915237
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparing charcoal and zeolite reflection filters for volatile anaesthetics: A laboratory evaluation.
    Sturesson LW; Frennström JO; Ilardi M; Reinstrup P
    Eur J Anaesthesiol; 2015 Aug; 32(8):521-6. PubMed ID: 25387299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The accuracy of the anesthetic conserving device (AnaConDa©) as an alternative to the classical vaporizer in anesthesia.
    Soro M; Badenes R; Garcia-Perez ML; Gallego-Ligorit L; Martí FJ; Aguilar G; Belda FJ
    Anesth Analg; 2010 Nov; 111(5):1176-9. PubMed ID: 20841411
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inhalative sedation with small tidal volumes under venovenous ECMO.
    Rand A; Zahn PK; Schildhauer TA; Waydhas C; Hamsen U
    J Artif Organs; 2018 Jun; 21(2):201-205. PubMed ID: 29508167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Functioning of the anaesthetic conserving device: aspects to consider for use in inhalational sedation].
    Meiser A; Bellgardt M; Vogelsang H; Sirtl C; Weber T
    Anaesthesist; 2010 Nov; 59(11):1029-40. PubMed ID: 20878139
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro performance evaluation of AnaConDa
    Bellgardt M; Drees D; Vinnikov V; Georgevici AI; Procopiuc L; Weber TP; Meiser A; Herzog-Niescery J
    J Clin Monit Comput; 2022 Feb; 36(1):169-177. PubMed ID: 33346879
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.